Fracture toughness evaluation at the interface of universal adhesives and tooth dentine using mini-interfacial fracture toughness test

被引:0
|
作者
Sanaee, Yasaman [1 ]
Shekofteh, Kiana [2 ]
AlBakhakh, Bahaa [3 ]
Hooshmand, Tabassom [2 ,4 ]
Hashemian, Atieh [4 ]
Nouri, Aisan [2 ]
Behroozibakhsh, Marjan [2 ,4 ]
机构
[1] Department of Orthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
[2] Department of Dental Biomaterials, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
[3] Department of Conservative, College of Dentistry, University of Almaaqal, Basrah, Iraq
[4] Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Using a modified mini-interfacial fracture toughness test (mini-IFT) and a designed mould for notch preparation, this study assessed the bonding effectiveness of self-etch universal adhesive systems. A total of 20 selected non-carious third molars were divided into four groups; G1: Clearfil SE Bond, G2: Clearfil S3 Bond Plus, G3: 3 M-Single bond Universal, G4: Ivoclar Tetric N-Bond Universal. The teeth were sectioned to obtain 1.5 × 2 mm wide longitudinal rectangular sections. A single notch then was prepared at the adhesive/dentine interface using a designed mould. The mini-iFT test was done via a 4-point bend testing until failure and the KIC was calculated. All specimens were observed using SEM. The data of each experimental group were analysed using one-way analysis of variance (ANOVA) and Weibull analysis. The results of one-way ANOVA did not indicate a significant difference between the four study groups (p > 0.05). The Weibull analysis showed that the characteristic strength of the groups ranges from 1.20 MPa to 1.39 MPa. The Weibull modulus m showed almost a similar plot in all study groups. According to SEM observations, the mode of failure for all samples was considered adhesive. Based on the results, the differences in mean mini-iFT values between the UAs and conventional self-etch adhesive group were not statistically significant. However, based on the left-censored data and the sample loss before and during the aging process, SE-bond showed better bonding quality than UAs. The low Weibull modulus in this study indicates nonuniform notches. More studies are needed to develop a repeatable and feasible method for preparing equal notches in mini-IFT test. © 2024 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
相关论文
共 50 条
  • [21] Interfacial fracture toughness test methodology for adhesive bonded joints
    Pang, HLJ
    Zhang, XR
    Shi, XQ
    Wang, ZP
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2002, 25 (02): : 187 - 191
  • [22] A new approach for bimaterial interface fracture toughness evaluation
    Wang, John Jy-An
    Wright, Ian G.
    Lance, Michael J.
    Liu, Ken C.
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2008, 130 (01):
  • [23] Evaluation of bonding effectiveness of a self-etch and an etch-and-rinse adhesive resin to un-treated and Er:Yag laser treated dentin using mini-interfacial fracture toughness test
    Behroozibakhsh, Marjan
    Davaie, Sotoudeh
    Monzavi, Abbas
    Abazari, Tayebeh
    Shahabi, Sima
    Pirmoradian, Maryam
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2019, 33 (11) : 1201 - 1214
  • [24] Measurement of the mode mix dependent interfacial fracture toughness for a Ti/Si interface using a modified decohesion test
    Modi, MB
    Sitaraman, SK
    ADVANCES IN ELECTRONIC PACKAGING 2003, VOL 1, 2003, : 559 - 573
  • [25] Fracture toughness evaluation using miniature specimen test and neural network
    Partheepan, G.
    Sehgal, D. K.
    Pandey, R. K.
    COMPUTATIONAL MATERIALS SCIENCE, 2008, 44 (02) : 523 - 530
  • [26] STATISTICAL EVALUATION OF FRACTURE-TOUGHNESS TEST DATA
    HAUGE, M
    THAULOW, C
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 1993, 16 (11) : 1187 - 1202
  • [27] Evaluation of Fracture Toughness Test Methods for Linepipe Steels
    Kang, Jidong
    Shen, Guowu
    Liang, Jie
    Brophy, Kyle
    Mendonca, Andrew
    Gianetto, James
    APPLICATION OF AUTOMATION TECHNOLOGY IN FATIGUE AND FRACTURE TESTING AND ANALYSIS, 2014, 1571 : 101 - 115
  • [28] Fracture toughness of bonds using interfacial stresses in four-point bending test
    Abdelhadi, Ousama M.
    Ladani, Leila
    Razmi, Jafar
    MECHANICS OF MATERIALS, 2011, 43 (12) : 885 - 900
  • [29] FRACTURE-TOUGHNESS OF DENTAL COMPOSITES DETERMINED USING THE SHORT-ROD FRACTURE-TOUGHNESS TEST
    PILLIAR, RM
    SMITH, DC
    MARIC, B
    JOURNAL OF DENTAL RESEARCH, 1986, 65 (11) : 1308 - 1314
  • [30] An unsymmetric double cantilever beam test for interfacial fracture toughness determination
    Sundararaman, V
    Davidson, BD
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 1997, 34 (07) : 799 - 817