Security constrained optimal power flow solution for practical transmission grid using hybrid use of generating plant and network restructuring

被引:0
|
作者
Singh, Bhoori [1 ]
Sharma, Avdhesh [1 ]
Garg, Akhil Ranjan [1 ]
Mahela, Om Prakash [2 ,3 ]
Khan, Baseem [4 ,5 ,6 ]
Ali, Ahmed [6 ]
机构
[1] MBM Univ Jodhpur, Dept Elect Engn, Jodhpur, Rajasthan, India
[2] Rajasthan Rajya Vidyut Prasaran Nigam Ltd, Power Syst Planning Div, Jaipur 302005, India
[3] Innovader IITian Padhaiwala LearnLab Pvt Ltd, Innovader Res Labs, Jaipur, India
[4] Hawassa Univ, Dept Elect & Comp Engn, Awasa, Ethiopia
[5] Zhejiang Univ, Ctr Renewable Energy & Micro, Zhuji 311816, Zhejiang, Peoples R China
[6] Univ Johannesburg, Dept Elect & Elect Engn, Johannesburg, South Africa
关键词
Bus voltage deviation; Generating plant; Genetic algorithm; Network restructuring; Security constrained optimal power flow; Transmission loss; Transmission utility grid;
D O I
10.1007/s42452-024-06301-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper presented a study on the security constrained optimal power flow (SCOPF) of a practical transmission utility grid network (TUGN). The objectives of reduction in the transmission losses of TUGN (TLGN) and to minimize the bus voltage deviations (BVD) are achieved by addition of thermal power plant (TPP) and network restructuring (NR). Identification of best fit node for generation injection is achieved using the method based on hybrid combination of analytic approach and genetic algorithm (GA). Efficacy of the proposed study is evaluated using the computation of energy equivalent to network loss saving, percentage derating of the load (PDOL), voltage profile, bus voltage deviations, and financial analysis (FA). Study is performed without and with contingency (N-1) for the base case network, TUGN with addition of TPP and TUGN with addition of TPP and NR. This is established that addition of TPP, addition of TPP with NR are effective to reduce the TLGN, improve the voltage profile and minimize the bus voltage deviations. This study is more efficient compared to various studies reported in literature. A study on security constrained optimal power flow of a practical transmission grid network is presented to meet the objectives of reduction in transmission losses and to minimize bus voltage deviations.A best fit node for generation injection is identified by hybrid combination of analytic approach and genetic algorithm to add thermal power plant and generation injection by network restructuring to achieve research objectives.Energy equivalent to network loss saving, percentage derating of load, voltage profile, bus voltage deviations, and financial analysis are used to establish efficacy of method. Study is performed without and with contingency (N-1). This study is more efficient compared to various studies of literature and can be implemented for practical transmission grid to achieve huge energy savings.
引用
收藏
页数:27
相关论文
共 50 条
  • [31] ASYNCHRONOUS PROGRAMMING-MODEL FOR THE CONCURRENT SOLUTION OF THE SECURITY CONSTRAINED OPTIMAL POWER-FLOW PROBLEM
    RODRIGUES, M
    SAAVEDRA, OR
    MONTICELLI, A
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1994, 9 (04) : 2021 - 2027
  • [32] Security constrained optimal power flow solution of wind-thermal generation system using modified bacteria foraging algorithm
    Panda, Ambarish
    Tripathy, M.
    ENERGY, 2015, 93 : 816 - 827
  • [33] Optimal Power Flow Solution Using Ant Manners for Electrical Network
    Allaoua, Boumediene
    Laoufi, Abdellah
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2009, 9 (01) : 34 - 40
  • [34] Optimization with Neural Network Feasibility Surrogates: Formulations and Application to Security-Constrained Optimal Power Flow
    Kilwein, Zachary
    Jalving, Jordan
    Eydenberg, Michael
    Blakely, Logan
    Skolfield, Kyle
    Laird, Carl
    Boukouvala, Fani
    ENERGIES, 2023, 16 (16)
  • [35] A solution of total transfer capability using Transient Stability Constrained Optimal Power Flow
    Kubokawa, Junji
    Yuan, Yue
    Yorino, Naoto
    Zoka, Yoshifumi
    Sasaki, Hiroshi
    Hakim, Lukmanul
    2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 2018 - +
  • [36] Security Constrained Optimal Power Flow with FACTS Devices Using Modified Particle Swarm Optimization
    Somasundaram, P.
    Muthuselvan, N. B.
    SWARM, EVOLUTIONARY, AND MEMETIC COMPUTING, 2010, 6466 : 639 - +
  • [37] Security Cost Analysis with Linear Ramp Model using Contingency Constrained Optimal Power Flow
    Lyu, Jae-Kun
    Kim, Mun-Kyeom
    Park, Jong-Keun
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2009, 4 (03) : 353 - 359
  • [38] Comparative Studies of Power Grid Security with Network Connectivity and Power Flow Information Using Unsupervised Learning
    Poudel, Shiva
    Ni, Zhen
    Zhong, Xiangnan
    He, Haibo
    2016 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2016, : 2730 - 2737
  • [39] Chaotic artificial bee colony algorithm based solution of security and transient stability constrained optimal power flow
    Ayan, Kursat
    Kilic, Ulas
    Barakli, Burhan
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 64 : 136 - 147
  • [40] Hybrid Imperialist Competitive Algorithm - A Meta-Heuristic Approach To Solve Security Constrained Optimal Power Flow
    Suganthi, Keerthana, V
    Meenakumari, R.
    2015 INTERNATIONAL CONFERENCE ON COGNITIVE COMPUTING AND INFORMATION PROCESSING (CCIP), 2015,