Lab-on-Chip Label-Free Sensing System for Electroporation Based on Time-Lapse Microscopy

被引:1
|
作者
Antonelli, Gianni [1 ,2 ]
Camera, Francesca [3 ]
Mencattini, Arianna [1 ,2 ,3 ]
Casciati, Arianna
Tanori, Mirella [3 ]
Zambotti, Alessandro [3 ]
Casti, Paola [1 ,2 ]
Curci, Giorgia [1 ,2 ]
Filippi, Joanna [1 ,2 ]
D'Orazio, Michele [1 ]
Merla, Caterina [3 ]
Martinelli, Eugenio [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Elect Engn, I-00133 Rome, Italy
[2] Univ Roma Tor Vergata, Interdisciplinary Ctr Adv Studies Lab On Chip & Or, I-00133 Rome, Italy
[3] Italian Natl Agcy Energy New Technol & Sustainable, Div Biotechnol, I-00123 Rome, Italy
关键词
Electroporation; Lab-on-a-chip; Fluorescence; Electrodes; Electric fields; Microscopy; Substrates; image analysis; label free; lab-on-a-chip; laser-induced graphene (LIG); machine learning; time-lapse microscopy;
D O I
10.1109/JSEN.2024.3463959
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electroporation has been shown to have considerable potential in biological research and clinical applications. This technique permits the opening of reversible or irreversible nanometric pores in cellular membranes by the application of a high-intensity electric field characterized by extremely short duration (i.e., microseconds, nanoseconds down to tens of picoseconds). Recently, also thanks to the spreading use of lab-on-chip, it was discovered that applying a high electric field to single cells can cause them to contract and generate blebs. Even though these effects are known in the literature, their correlation with the electroporation phenomenon is still unclear. For this reason, in this work, we present a reliable, low-cost sensing system based on a lab-on-chip platform with transferred laser-induced graphene (LIG) electrodes to study electroporation by bright-field and fluorescence time-lapse microscopy. The acquired video was then used to extrapolate the calcium intake due to electroporation, cell contractility, and morphology over time. The two abovementioned side effects were finally correlated with electroporation and used to estimate its efficacy on single cells, exploiting calcium intake information as the ground truth. The proposed sensing system could be used to predict the electroporation phenomenon easily and even in a label-free modality, using exclusively the morphological variations induced in the single cells.
引用
收藏
页码:36306 / 36315
页数:10
相关论文
共 50 条
  • [31] SYMMETRY-BASED MITOSIS DETECTION IN TIME-LAPSE MICROSCOPY
    Gilad, Topaz
    Bray, Mark-Anthony
    Carpenter, Anne E.
    Raviv, Tammy Riklin
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 164 - 167
  • [32] Label-free Bio-aerosol Sensing Using On-Chip Holographic Microscopy and Deep Learning
    Wu, Yichen
    Calis, Ayfer
    Luo, Yi
    Chen, Cheng
    Lutton, Maxwell
    Rivenson, Yair
    Lin, Xing
    Koydemir, Hatice Ceylan
    Zhang, Yibo
    Wang, Hongda
    Gorocs, Zoltan
    Ozcan, Aydogan
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2019,
  • [33] LABEL-FREE DETECTION OF LEUKEMIA CELLS WITH A LAB-ON-A-CHIP SYSTEM INTEGRATING DIELECTROPHORESIS AND CMOS IMAGING
    Demircan, Y.
    Orguc, S.
    Musayev, J.
    Ozgur, E.
    Erdem, M.
    Gunduz, U.
    Eminoglu, S.
    Kulah, H.
    Akin, T.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 1589 - 1592
  • [34] Direct writing of optical microresonators in a lab-on-a-chip for label-free biosensing
    Kelemen, L.
    Lepera, E.
    Horvath, B.
    Ormos, P.
    Osellame, R.
    Vazquez, R. Martinez
    LAB ON A CHIP, 2019, 19 (11) : 1985 - 1990
  • [35] Real-time, label-free monitoring of the cell cycle with a cellular impedance sensing chip
    Wang, Lei
    Wang, Lei
    Yin, Hongying
    Xing, Wanli
    Yu, Zhongyao
    Guo, Min
    Cheng, Jing
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (05): : 990 - 995
  • [36] Webcam camera as a detector for a simple lab-on-chip time based approach
    Wongwilai, Wasin
    Lapanantnoppakhun, Somchai
    Grudpan, Supara
    Grudpan, Kate
    TALANTA, 2010, 81 (03) : 1137 - 1141
  • [37] Real-time Image Processing for Microscopy-based Label-free Imaging Flow Cytometry in a Microfluidic Chip
    Heo, Young Jin
    Lee, Donghyeon
    Kang, Junsu
    Lee, Keondo
    Chung, Wan Kyun
    SCIENTIFIC REPORTS, 2017, 7
  • [38] High-Throughput and Label-Free Single Nanoparticle Sizing Based on Time-Resolved On-Chip Microscopy
    McLeod, Euan
    Dincer, T. Umut
    Veli, Muhammed
    Ertas, Yavuz N.
    Chau Nguyen
    Luo, Wei
    Greenbaum, Alon
    Feizi, Alborz
    Ozcan, Aydogan
    ACS NANO, 2015, 9 (03) : 3265 - 3273
  • [39] Real-time Image Processing for Microscopy-based Label-free Imaging Flow Cytometry in a Microfluidic Chip
    Young Jin Heo
    Donghyeon Lee
    Junsu Kang
    Keondo Lee
    Wan Kyun Chung
    Scientific Reports, 7
  • [40] A low-cost automated focusing system for time-lapse microscopy
    Wright, E. F.
    Wells, D. M.
    French, A. P.
    Howells, C.
    Everitt, N. M.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (02)