Magnetic circuit for current measurement of transmission line

被引:0
|
作者
Li, Yuting [1 ,4 ]
Gao, Jiale [3 ,4 ]
Yang, Yuqiang [1 ,3 ,4 ]
Mu, Xiaoguang [1 ,2 ]
Zheng, Mingjun [3 ]
机构
[1] Guangdong Ocean Univ, Res Ctr Guangdong Smart Oceans Sensor Networks & E, Zhanjiang, Peoples R China
[2] Guangdong Ocean Univ, Sch Mech & Power Engn, Zhanjiang, Peoples R China
[3] Guangdong Prov Key Lab Intelligent Equipment South, Zhanjiang, Peoples R China
[4] Guangdong Ocean Univ, Shenzhen Inst, Shenzhen, Peoples R China
关键词
Fiber optic current sensors; magnetic circuit; magnetic measurement; SENSOR; INTERFEROMETER;
D O I
10.1080/00150193.2024.2322374
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Generally, the measurement of power line current is done by measuring the magnetic field around it, so how to increase the magnetic field at the sensor head is the key to achieve high sensitivity detection. A ferrite magnetic circuit (FMC) system was proposed to improve the conversion efficiency of transmission line current to magnetic field at the sensor head. The FMC is designed as a rectangular structure with a slit in which the sensing head is placed. The magnetic field generated by the current is concentrated at the sensing head by using the high permeability of ferrite. The simulation results shows that the magnetic field in the slit is mainly determined by magnetic permeability, the length and the cross-sectional area of the magnetic bar. It monotonically increases with the increasing of magnetic permeability, and decreased gradually with the slit width increasing. It increased rapidly at first and then increased slowly with the increasing of the cross-sectional area of the magnetic bar. It has a good practical value to improve the sensitivity of optical fiber current sensor.
引用
收藏
页码:2030 / 2037
页数:8
相关论文
共 50 条
  • [1] A Stable Energy Acquisition System Based on Magnetic Circuit Coupled Current Transformer for Transmission Line
    Zhang, Pengyu
    Meng, Runquan
    Ren, Chunguang
    Zhang, Ying
    2019 3RD INTERNATIONAL WORKSHOP ON RENEWABLE ENERGY AND DEVELOPMENT (IWRED 2019), 2019, 267
  • [2] Circuit for the Measurement of Current in DC Power Transmission Lines.
    Rzewuski, Michal
    Przeglad Elektrotechniczny, 1975, 51 (07): : 311 - 315
  • [3] Protection of Double-circuit Transmission Line Using Superimposed Current
    Bhalja, B.
    Purohit, Swati
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2011, 39 (06) : 590 - 604
  • [4] Study on the Application of Optical Current Sensor for Lightning Current Measurement of Transmission Line
    Ge, Jin-ming
    Shen, Yan
    Yu, Wen-bin
    Han, Yue
    Duan, Fang-wei
    SENSORS, 2019, 19 (23)
  • [5] Transmission line with a teed circuit
    Kang, SH
    Lee, SJ
    Kwon, YJ
    Kang, YC
    2001 POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2001, : 921 - 926
  • [6] PROBABILISTIC INTERRUPTING CURRENT RATING OF TRANSMISSION-LINE CIRCUIT-BREAKERS
    NAHMAN, J
    BEKUT, D
    ELECTRIC POWER SYSTEMS RESEARCH, 1994, 28 (03) : 165 - 170
  • [7] Mitigation of magnetic field under double-circuit overhead transmission line
    Gouda, Osama Elsayed
    El Dein, Adel Z.
    Telkomnika - Indonesian Journal of Electrical Engineering, 2012, 10 (08): : 2272 - 2284
  • [8] On-line measurement of high voltage breaking current for vacuum circuit breaker
    Tsinghua University, Beijing 100084, China
    不详
    Dianli Xitong Zidonghue, 2007, 3 (91-94):
  • [9] The magnetic circuit of samples in magnetic measurement
    Derlecki, Stanislaw
    Kalus-Jecek, Bozenna
    Kusmierek, Zygmunt
    PRZEGLAD ELEKTROTECHNICZNY, 2007, 83 (01): : 126 - 129
  • [10] Research on induced current and induced voltage of 500 kV double circuit transmission line
    Ren Hongtao
    Zhang Ying
    ENERGY REPORTS, 2021, 7 : 216 - 223