Optimization of cooling system parameters with temperature field of mass concrete during hydration

被引:0
|
作者
Wang, Songqing [1 ,2 ]
Duan, Jianan [1 ,2 ]
Zhang, Yinuo [1 ,2 ]
He, Shijing [1 ,2 ]
Hao, Xiangwei [1 ]
机构
[1] Northeast Forestry Univ, Sch Civil Engn & Transportat, Harbin 150040, Peoples R China
[2] Northeast Forestry Univ, Inst Artificial Environm Control & Energy Applicat, Harbin 150040, Peoples R China
关键词
Mass concrete; Hydration heat; Cooling pipe system; Parameter optimization; SIMULATION; PIPES; HEAT;
D O I
10.1016/j.csite.2024.105456
中图分类号
O414.1 [热力学];
学科分类号
摘要
Embedded cooling pipe system is regarded as the primary means in mass concrete to control the temperature. The effects of three factors are investigated on the thermal field of mass concrete by the combination of measurement, theoretical analyze and numerical simulation in this paper, including cooling pipe spacing, pipe diameter and pipe arrangement. The results demonstrate that the peak temperature is reduced by the increase in both of the pipe distance and pipe diameter. The peak temperature is measured to decrease from 1 degrees C to 3 degrees C on the monitoring points, with additional 0.5 m of pipe spacing or 10 mm of pipe diameter. The serious influence is conducted by the pipe diameter on the temperature difference, and the selection of cooling pipe diameter is considered to balance multiple problems in the project necessarily. The serpentine arrangement is more widely used for better cooling and construction in the comparison of the circular arrangement. The results on the optimization of cooling system are utilized for the project to control the hydration heat accurately and reduce or even prevent the generation of cracks.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Influence factors on the temperature field in a mass concrete
    Aniskin, Nikolay
    Trong-Chuc Nguyen
    XXII INTERNATIONAL SCIENTIFIC CONFERENCE: CONSTRUCTION THE FORMATION OF LIVING ENVIRONMENT (FORM-2019), 2019, 97
  • [22] Simulation Analysis of Mass Concrete Temperature Field
    Zhou Yunchuan
    Bai Liang
    Yang Shengyuan
    Chen Guting
    2012 INTERNATIONAL CONFERENCE ON STRUCTURAL COMPUTATION AND GEOTECHNICAL MECHANICS (SCGM 2012), 2012, 5 : 5 - 12
  • [23] Study on Temperature Control and Cracking Risk of Mass Concrete Sidewalls with a Cooling-Pipe System
    Chen, Chunchao
    Chen, Shihai
    BUILDINGS, 2024, 14 (04)
  • [24] Influence of cement type on heat of hydration and temperature rise of the mass concrete
    Lee, M. H.
    Khil, B. S.
    Yun, H. D.
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2014, 21 (05) : 536 - 542
  • [25] Experimental Study on Hydration Heat Control of Mass Concrete by Vertical Pipe Cooling Method
    Seo, Tae-Seok
    Kim, Sam-Soo
    Lim, Chang-Keun
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2015, 14 (03) : 657 - 662
  • [26] Improved buried pipe element method for temperature-field calculation of mass concrete with cooling pipes
    Zhu, Zhenyang
    Liu, Yi
    Fan, Zhe
    Qiang, Sheng
    Xie, Zhiqiang
    Chen, Weimin
    Wu, Congcong
    ENGINEERING COMPUTATIONS, 2020, 37 (08) : 2619 - 2640
  • [27] NEW PLANNING OF PIPE COOLING IN TEMPERATURE CONTROL FOR MASS CONCRETE
    Tang Hao
    Cai De-suo
    Yang li
    MECHATRONICS AND APPLIED MECHANICS II, PTS 1 AND 2, 2013, 300-301 : 1584 - +
  • [28] Thermal analysis of hydration heat in concrete structures with pipe-cooling system
    Kim, JK
    Kim, KH
    Yang, JK
    COMPUTERS & STRUCTURES, 2001, 79 (02) : 163 - 171
  • [29] Analysis of the temperature field of hydration heat in a hollow and high concrete pier
    Tang, Chunping (tcp501@163.com), 1600, Universidad Central de Venezuela (55):
  • [30] Experimental research on the hydration heat temperature field of hollow concrete piers
    Peng, Jun
    Tang, Chunping
    Zhang, Liangliang
    Saeed, Ayad Thabit
    Open Construction and Building Technology Journal, 2014, 8 (01): : 482 - 487