Fault Diagnosis of Oil-Immersed Transformer based on TSNE and IBA-SA-SVM

被引:1
|
作者
Feng, Wenqing [1 ,2 ]
Zhang, Guoyong [1 ,2 ]
Ouyang, Yi [1 ,2 ]
Pi, Xinyu [1 ,2 ]
He, Lifu [1 ,2 ]
Luo, Jing [1 ,2 ]
Yi, Lingzhi [3 ]
Guo, You [3 ]
机构
[1] State Key Laboratory of Disaster Prevention and Reduction for Power Grid Transmission and Distribution Equipment, Hunan Province, Changsha,410129, China
[2] State Grid Hunan Electric Power Company Disaster Prevention and Reduction Center, Hunan Province, Changsha,410129, China
[3] School of Automation and Electronic Information, Xiang-tan University, Hunan, Xiangtan,411100, China
关键词
Dimensionality - Fault diagnose; - Faults diagnosis - Improved beetle antenna search algorithm - Oil immersed transformers - Power - Search Algorithms - Stochastic neighbor embedding - Support vectors machine - T-distributed stochastic neighbor embedding;
D O I
暂无
中图分类号
学科分类号
摘要
Background: With the rapid development of the power system, oil-immersed transformers are widely used in the substation and distribution system. The faults of oil-immersed transformers are a large threat to the power system. Therefore, it is significant that the faults of oil-immersed transformers can be diagnosed accurately. Objective: To accurately diagnose the faults of oil-immersed transformers through machine learning methods and swarm intelligence algorithms. Methods: To accurately diagnose the faults of oil-immersed transformers, a fault diagnosis method based on T-distributed stochastic neighbor embedding and support vector machine is proposed. The improved beetle antennae search algorithm is used to optimize the parameters of the support vector machine. Firstly, the non-coding ratio method is used to obtain nine-dimensional characteristic indices. Secondly, the original nine-dimensional data are reduced to three-dimensional by T-distributed stochastic neighbor embedding. Lastly, the data after dimensionality reduction are used as the input of the support vector machine optimized by improved beetle antennae search algorithm and the fault types of transformers can be diagnosed. Results: The accuracy rate is 94.53% and the operation time is about 1.88s. The results indicate that the method proposed by this paper is reasonable. Conclusion: The experimental results show that the method proposed by this paper has a high accuracy rate and low operation time. Mixed faults that are difficult to diagnose also can be diagnosed by this paper's method. In the era of big data, there is a lot of data on transformers, so the method proposed in this paper has certain engineering significance. © 2022 Bentham Science Publishers.
引用
下载
收藏
页码:504 / 514
相关论文
共 50 条
  • [21] Study on Fault Detection Robot for Oil-immersed Transformer based on WiFi control
    Huang, Ronghui
    Zhao, Yuming
    Li, Xun
    Feng, Yingbin
    Wu, Guoxing
    Li, Zhigang
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 50 - 55
  • [22] Oil-immersed Transformer Internal Thermoelectric Potential Fault Diagnosis Based on Decision-tree of KNIME Platform
    Han, Yuanyuan
    Zhao, Dongming
    Hou, Hui
    7TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT 2016) / THE 6TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY (SEIT-2016) / AFFILIATED WORKSHOPS, 2016, 83 : 1321 - 1326
  • [23] Fault Diagnosis of Oil-immersed Transformer Based on Improved Seagull Optimization Algorithm to Optimize Wavelet Neural Network
    Wang, Jingou
    Shan, Yafeng
    Fu, Hua
    2022 9TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2022, : 1156 - 1162
  • [24] Fault diagnosis against oil-immersed transformer used on PNN and GM (1,1)
    Jia, Honghong
    Dai, Wenzhan
    2007 IEEE INTERNATIONAL CONFERENCE ON INTEGRATION TECHNOLOGY, PROCEEDINGS, 2007, : 394 - +
  • [25] Synthetic diagnostic method for insulation fault of oil-immersed power transformer
    Qian, Z
    Yang, MZ
    Yan, Z
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 872 - 875
  • [26] The study of fault diagnosis model of dga for oil-immersed transformer based on Fuzzy means Kernel Clustering and SVM multi-class object simplified structure
    Liu, Dong-Hui
    Bian, Jian-Peng
    Sun, Xiao-Yun
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-7, 2008, : 1505 - 1509
  • [27] Research on Vibration Characteristic Analysis and Fault Diagnosis Method of Oil-Immersed Transformer Based on Multi-Physics Coupling
    Yuan, Fating
    Yan, Zhiwei
    Zhang, Renjie
    Yang, Yi
    Jian, Shengkai
    Tang, Bo
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2024, 19 (10) : 1621 - 1630
  • [28] Fault Diagnosis of Oil-Immersed Power Transformer Based on Difference-Mutation Brain Storm Optimized Catboost Model
    Zhang, Mei
    Chen, Wanli
    Zhang, Yu
    Liu, Fei
    Yu, Dongshun
    Zhang, Chaoyin
    Gao, Li
    IEEE ACCESS, 2021, 9 : 168767 - 168782
  • [29] Conventional methods of dissolved gas analysis using oil-immersed power transformer for fault diagnosis: A review
    Ali, Mohd Syukri
    Bakar, Ab Halim Abu
    Omar, Azimah
    Jaafar, Amirul Syafiq Abdul
    Mohamed, Siti Hajar
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 216
  • [30] Traditional fault diagnosis methods for mineral oil-immersed power transformer based on dissolved gas analysis: Past, present and future
    Nanfak, Arnaud
    Samuel, Eke
    Fofana, Issouf
    Meghnefi, Fethi
    Ngaleu, Martial Gildas
    Kom, Charles Hubert
    IET NANODIELECTRICS, 2024,