Removal of Vibration Interference Artifacts in Electrical Impedance Tomography Monitoring Using Residual Learning Strategy

被引:0
|
作者
Ye, Jian'an [1 ,2 ]
Tian, Xiang [1 ,2 ]
Liu, Xuechao [1 ,2 ]
Zhang, Weirui [3 ]
Zhang, Tao [1 ,2 ,4 ]
Zhang, Liangliang [5 ]
Wang, Pu [1 ,2 ]
Xue, Huijun [1 ,2 ]
Xu, Canhua [1 ,2 ]
Fu, Feng [1 ,2 ]
机构
[1] Fourth Mil Med Univ, Dept Biomed Engn, Xian 710032, Peoples R China
[2] Fourth Mil Med Univ, Shaanxi Prov Key Lab Bioelectromagnet Detect & Int, Xian 710032, Peoples R China
[3] Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan 430074, Peoples R China
[4] Xining Joint Logist Support Ctr, Drug & Instrument Supervis & Inspect Stn, Lanzhou 730050, Peoples R China
[5] Xi An Jiao Tong Univ, Sch Software Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrical impedance tomography; Image reconstruction; Interference; Conductivity; Noise; Feature extraction; Convolutional neural networks; Electrical impedance tomography (EIT); interference suppression; postprocessing method; residual convolutional neural network (CNN); vibration interference; RECONSTRUCTION; NETWORK; SYSTEM; TREMOR; EIT;
D O I
10.1109/TIM.2024.3440389
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical impedance tomography (EIT) can be used for real-time bedside monitoring of pathological changes in human brain tissue and dynamic imaging. However, EIT measurement signals are easily disturbed by noise, tremor in stroke patients, and other factors in clinical practice, which result in significant artifacts in the reconstructed images. These artifacts degrade the image quality and affect the detection of focal targets. To address this problem, we propose a multiscale 1-D residual convolutional network (MS-1DResCNN) to remove chaotic noise and interference from the conductivity distribution data and retain the target feature data, thereby improving the robustness of the reconstruction algorithm to noise and interference. The structural similarity (SSIM) and normalized mean square error (NMSE) were used to evaluate the performance of the proposed method in suppressing image reconstruction artifacts under noise-free conditions, different noise simulation levels, and varying vibration interference frequencies. The results of physical experiments showed that, under 10-Hz vibration interference, the reconstructed images using the MS-1DResCNN method improved the SSIM by 40.4%, 22.0%, 17.4%, and 11.7% and reduced the NMSE by 74.3%, 72.4%, 65.2%, and 29.5%, compared to the damped least squares (DLSs), artificial neural network (ANN), error-constraint network (Ec-Net), and U-Net methods, respectively. This method effectively improves the anti-interference ability of conditional algorithms, significantly reduces artifacts in EIT images, and makes the perturbation target clearer and more precise, thereby providing stable and reliable algorithmic support for the clinical application of EIT.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Improving Electrical Impedance Tomography Reconstruction Algorithms By The Reduction Of Movement Artifacts
    Robijns, F.
    Kneyber, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [22] Piezoresistive nanocomposite sensing using electrical impedance tomography and machine learning
    Alawy, A.
    Mostaghimi, H.
    Amani, S.
    Rezvani, S.
    Park, S. S.
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 377
  • [23] Electrode Placement Optimization for Electrical Impedance Tomography Using Active Learning
    Lee, Junhyeong
    Park, Kyungseo
    Park, Kundo
    Kim, Yongtae
    Kim, Jung
    Ryu, Seunghwa
    ADVANCED ENGINEERING MATERIALS, 2024, 26 (11)
  • [24] Hybrid machine learning in electrical impedance tomography
    Rymarczyk, Tomasz
    Klosowski, Grzegorz
    Guzik, Miroslaw
    Niderla, Konrad
    Lipski, Jerzy
    PRZEGLAD ELEKTROTECHNICZNY, 2021, 97 (12): : 169 - 172
  • [25] Solving electrical impedance tomography with deep learning
    Fan, Yuwei
    Ying, Lexing
    JOURNAL OF COMPUTATIONAL PHYSICS, 2020, 404
  • [26] Research on excitation strategy of open electrical impedance tomography
    Fan, Wenru
    Hao, Kuihong
    Xu, Yanbin
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2014, 35 (06): : 1269 - 1275
  • [27] Preliminary Research on Monitoring of Cerebral Ischemia Using Electrical Impedance Tomography Technique
    Shi, Xuetao
    You, Fusheng
    Fu, Feng
    Liu, Ruigang
    You, Yu
    Dai, Meng
    Dong, Xiuzhen
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1188 - +
  • [28] Non-Invasive Hemodynamic Monitoring in Hemodialysis Using Electrical Impedance Tomography
    Oh, Tongin
    Mok, Jinwon
    Moon, Ju Young
    Kim, Yang Gyun
    Lee, Sangho
    Jung, Su Woong
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2022, 33 (11): : 700 - 701
  • [29] Image monitoring for an intraperitoneal bleeding model of pigs using electrical impedance tomography
    Shuai Wanjun
    You Fusheng
    Zhang Wei
    Zhang Hongyi
    Fu Feng
    Shi Xuetao
    Liu Ruigang
    Xu Canhua
    Dong Xiuzhen
    Bao Tingyi
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (02) : 217 - 225
  • [30] Image Monitoring for Head Phantom of Intracranial Hemorrhage Using Electrical Impedance Tomography
    Wang, Lei
    Liu, Wen-Bo
    Yu, Xiao
    Xu, Can-Hua
    Dong, Xiu-Zhen
    Gao, Feng
    2016 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS), 2016, : 1408 - 1411