Cleavage Reaction Lateral Flow Assays for Salivary Pepsin Measurement Using a Pepsin-Susceptible Peptide Substrate

被引:0
|
作者
Kang, Sung-Woong [1 ]
Lee, Young Ju [2 ]
Lee, Jae-Chul [3 ]
Eun, Young-Gyu [4 ]
Lee, Gi-Ja [1 ,2 ,5 ]
机构
[1] Kyung Hee Univ, Grad Sch, Dept Med Engn, Seoul 02447, South Korea
[2] Kyung Hee Univ, Coll Med, Dept Biomed Engn, Seoul 02447, South Korea
[3] Korea Inst Ind Technol, Text Innovat R&D Dept, Ansan 15588, South Korea
[4] Kyung Hee Univ, Coll Med, Med Ctr, Dept Otolaryngol Head & Neck Surg, Seoul 02447, South Korea
[5] Kyung Hee Univ, Grad Sch, Dept Precis Med, Seoul 02447, South Korea
基金
新加坡国家研究基金会;
关键词
pepsin; saliva; lateral flow assay; cleavage reaction; pepsin-susceptible peptide substrate; multifunctional strip cassette; SENSITIVE DETECTION; GOLD NANOPARTICLES; MARKER;
D O I
10.3390/chemosensors12110241
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, we introduce a novel cleavage reaction lateral flow assay (LFA) based on pepsin activity against a pepsin-susceptible peptide (PSP) substrate to detect salivary pepsin. Two types of cleavage reaction LFAs, the within-tube and on-strip cleavage reactions, were prepared based on the PSP and pepsin reaction location. In the within-tube cleavage reaction LFA, samples were treated in the microtube within a heating block for 30 min separately and subsequently developed with running buffer in the LFA. For the on-strip cleavage reaction, samples were treated on the reaction zone of the strip within the heating zone of the multifunctional strip cassette for 10 min. After developing the running buffer in the LFA, the assay image was obtained using a universal mobile reader with a multifunctional strip cassette. The within-tube cleavage reaction LFA showed high sensitivity (limit of detection [LOD] 1.9 ng/mL), good specificity, and high reproducibility. This assay exhibited better linearity in the log concentration range of pepsin (4-500 ng/mL) than a commercially available dipstick assay. The on-strip cleavage reaction LFA showed a similar sensitivity (LOD 1.4 ng/mL) to that of the within-tube reaction assay. Therefore, we expect these cleavage reaction LFAs using PSP to be utilized as simple and effective tools to detect salivary pepsin.
引用
收藏
页数:13
相关论文
共 5 条
  • [1] Determination of pepsin in human saliva using pepsin-susceptible peptide reporter and colorimetric dipstick assay: a prospective, cross-sectional study
    Young Ju Lee
    Joo Kyung Noh
    Seon Rang Woo
    Sung-Woong Kang
    Young-Gyu Eun
    Gi-Ja Lee
    Microchimica Acta, 2024, 191
  • [2] Determination of pepsin in human saliva using pepsin-susceptible peptide reporter and colorimetric dipstick assay: a prospective, cross-sectional study
    Lee, Young Ju
    Noh, Joo Kyung
    Woo, Seon Rang
    Kang, Sung-Woong
    Eun, Young-Gyu
    Lee, Gi-Ja
    MICROCHIMICA ACTA, 2024, 191 (02)
  • [3] SPECTROPHOTOMETRIC MEASUREMENT OF PEPSIN CATALYTIC ACTIVITY WITH A SYNTHETIC PEPTIDE AS SUBSTRATE
    ANDERSON, KW
    AMERICAN BIOTECHNOLOGY LABORATORY, 1989, 7 (6A): : 33 - 34
  • [4] Online High-Flow Peptide Immunoaffinity Enrichment and Nanoflow LC-MS/MS: Assay Development for Total Salivary Pepsin/Pepsinogen
    Neubert, Hendrik
    Gale, Jeremy
    Muirhead, David
    CLINICAL CHEMISTRY, 2010, 56 (09) : 1413 - 1423
  • [5] Cell-phone-based measurement of TSH using Mie scatter optimized lateral flow assays
    You, David J.
    Park, Tu San
    Yoon, Jeong-Yeol
    BIOSENSORS & BIOELECTRONICS, 2013, 40 (01): : 180 - 185