An automatic cough counting method and system construction for portable devices

被引:0
|
作者
Wang, Yixuan [1 ]
Yang, Kehaoyu [2 ,3 ]
Xu, Shaofeng [2 ,3 ]
Rui, Shuwang [2 ,3 ]
Xie, Jiaxing [4 ]
Wang, Juncheng [5 ]
Wang, Xin [6 ]
机构
[1] Engineering Training Centre, Beihang University, Beijing, China
[2] School of Automation Science and Electrical Engineering, Beihang University, Beijing, China
[3] Liupanshan Laboratory, Yinchuan, China
[4] State Key Laboratory of Respiratory Disease, Guangzhou, China
[5] Institute of Stomatology, First Medical Center, Chinese PLA General Hospital, Beijing, China
[6] Nineth Medical Center of PLA General Hospital Gynaecology and Obstetrics, Chinese PLA General Hospital, Beijing, China
基金
中国国家自然科学基金;
关键词
D O I
10.3389/fbioe.2024.1477694
中图分类号
学科分类号
摘要
Introduction: Cough is a common symptom of respiratory diseases, and prolonged monitoring of cough can help assist doctors in making judgments about patients’ conditions, among which cough frequency is an indicator that characterizes the state of the patient’s lungs. Therefore, the aim of this paper is to design an automatic cough counting system to monitor the number of coughs per minute for a long period of time. Methods: In this paper, a complete cough counting process is proposed, including denoising, segment extraction, eigenvalue calculation, recognition, and counting process; and a wearable automatic cough counting device containing acquisition and reception software. The design and construction of the algorithm is based on realistically captured cough-containing audio from 50 patients, combined with short-time features, and Meier cepstrum coefficients as features characterizing the cough. Results: The accuracy, sensitivity, specificity, and F1 score of the method were 93.24%, 97.58%, 86.97%, and 94.47%, respectively, with a Kappa value of 0.9209, an average counting error of 0.46 counts for a 60-s speech segment, and an average runtime of 2.80 ± 2.27 s. Discussion: This method improves the double threshold method in terms of the threshold and eigenvalues of the cough segments’ sensitivity and has better performance in terms of accuracy, real-time performance, and computing speed, which can be applied to real-time cough counting and monitoring in small portable devices with limited computing power. The developed wearable portable automatic cough counting device and the accompanying host computer software application can realize the long-term monitoring of patients’ coughing condition. Copyright © 2024 Wang, Yang, Xu, Rui, Xie, Wang and Wang.
引用
收藏
相关论文
共 50 条
  • [1] A portable automatic cough analyser in the ambulatory assessment of cough
    Malgorzata Krajnik
    Iwona Damps-Konstanska
    Lucyna Gorska
    Ewa Jassem
    [J]. BioMedical Engineering OnLine, 9
  • [2] A portable automatic cough analyser in the ambulatory assessment of cough
    Krajnik, Malgorzata
    Damps-Konstanska, Iwona
    Gorska, Lucyna
    Jassem, Ewa
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2010, 9
  • [3] A semi automatic method to reduce the time taken for manual cough counting.
    Sumner, H.
    Kelsall, A.
    Woodcock, A. A.
    Smith, J.
    McGuinness, K.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [4] A lightweight network for portable fry counting devices
    Li, Weiran
    Zhu, Qian
    Zhang, Hanyu
    Xu, Ziyu
    Li, Zhenbo
    [J]. APPLIED SOFT COMPUTING, 2023, 136
  • [5] Accuracy of portable devices in measuring peak cough flow
    Kulnik, Stefan Tino
    MacBean, Victoria
    Birring, Surinder Singh
    Moxham, John
    Rafferty, Gerrard Francis
    Kalra, Lalit
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (02) : 243 - 257
  • [6] Method for Automatic Construction of Queuing System Models
    Valakevicius, Eimutis
    Lazauskas, Tomas
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON MODELING, SIMULATION AND APPLIED MATHEMATICS, 2015, 122 : 115 - 119
  • [7] Interactive Construction of Panoramic Images on Portable Devices
    Garashchenko, F. G.
    Kobzar, A. Yu.
    [J]. JOURNAL OF AUTOMATION AND INFORMATION SCIENCES, 2013, 45 (12) : 21 - 35
  • [8] The Pedestrian Detecting and Counting System Based on Automatic Method of CCD Calibration
    Wang, Yuejin
    Guo, Sumei
    Huang, Hong
    [J]. 2017 9TH INTERNATIONAL CONFERENCE ON ADVANCED INFOCOMM TECHNOLOGY (ICAIT 2017), 2017, : 329 - 333
  • [10] SELF-CONTAINED AUTOMATIC AND PORTABLE APPARATUS FOR THE COUNTING OF PARTICLES.
    Cabrol, C.
    Lopez, A.
    Fontan, J.
    [J]. 1600, (03):