Transient power angle stability analysis and optimization strategy of a VSG-DFIG in a weak power grid

被引:0
|
作者
Zhang, Ao [1 ]
Wang, Xinda [2 ]
Zhang, Xueguang [1 ]
机构
[1] School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin,150001, China
[2] State Grid Jiangsu Electric Power Co., Ltd., Electric Power Research Institute, Nanjing,211100, China
基金
中国国家自然科学基金;
关键词
Asynchronous generators - Electric power system control - Electric power system protection - Electric power system stability - Hardware-in-the-loop simulation - Static Var compensators - Synchronous generators - Transient analysis - Transient stability;
D O I
10.19783/j.cnki.pspc.240426
中图分类号
学科分类号
摘要
The voltage-source doubly-fed induction generator (DFIG), controlled by the typical grid-forming control method of a virtual synchronous generator (VSG), can provide damping and inertia to the power grid. However, during voltage dip faults, they may encounter similar power angle stability issues to those experienced by synchronous machines. First, the impact of grid-side converter power and variable power reference on transient power angle stability using the equal-area criterion when the grid voltage experiences a three-phase symmetrical voltage dip are analyzed. To adapt the variable power reference control strategy to the dynamic changes of the grid-side converter during the transient period, a stability optimization method for a VSG-controlled DFIG (VSG-DFIG) based on transient power angle feedforward is proposed. The method compensates for the imbalance torque of the VSG by feeding forward the power angle deviation, thus accelerating the deceleration process after the power angle passes the equilibrium point during the transient period. The selection range of the feedforward coefficient is determined by the acceleration and deceleration areas of the transient power angle curve, ensuring that the power angle converges while maintaining the fault ride-through capability of the voltage-source control. Finally, the correctness of the theoretical analysis and the effectiveness of the optimization method are verified through simulation and a hardware-in-the-loop experimental platform. © 2024 Power System Protection and Control Press. All rights reserved.
引用
收藏
页码:73 / 81
相关论文
共 50 条
  • [41] Analysis method of influence of wind power access proportion on transient power angle stability of power system
    Jiang H.
    Zhou Z.
    Cai J.
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (07): : 53 - 61
  • [42] Comparison of Transient Stability between Wind Farm based on DFIG and Traditional Power Plant in an Actual Grid
    Hou, Hongjing
    Lin, Li
    Wu, Tao
    Miao, Youzhong
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [43] Transient Characteristics Analysis of DFIG during Power Grid Fault and Crowbar Resistance Adaptive Tuning
    Gu, Y. J.
    Nie, Y.
    Jiao, Y. J.
    Xu, Y. Q.
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON COMPUTER INFORMATION SYSTEMS AND INDUSTRIAL APPLICATIONS (CISIA 2015), 2015, 18 : 204 - 207
  • [44] Transient Stability of the Grid with a Wind Power Plant
    Muljadi, E.
    Nguyen, T. B.
    Pai, M. A.
    [J]. 2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, 2009, : 312 - +
  • [45] Active power oscillation suppression strategy for dual-VSG grid based on power differential term
    Zhu J.
    Yuan Y.
    Liu P.
    Du S.
    Guo X.
    Yang M.
    Qu Y.
    [J]. Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2024, 28 (01): : 177 - 188
  • [46] Transient Angle Stability Analysis of Grid-Connected Converters with the First-order Active Power Loop
    Wu, Heng
    Wang, Xiongfei
    [J]. THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018), 2018, : 3011 - 3016
  • [47] Transient voltage stability analysis of Hunan Power Grid with infeed UHVDC
    Qiu W.
    He J.
    Yu Z.
    Xu X.
    Yang D.
    Liu N.
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (10): : 168 - 173
  • [48] Cascading Failures and Transient Stability Experiment Analysis in Power Grid Security
    Poudel, Shiva
    Ni, Zhen
    Hansen, Timothy M.
    Tonkoski, Reinaldo
    [J]. 2016 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT), 2016,
  • [49] A Method for On-Line Analysis of Large Power Grid Transient Stability
    Li, Yue
    Zhang, Wenchao
    Cu, Xueping
    Zhao, Bing
    Zhang, Yanping
    [J]. POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, : 505 - +
  • [50] New strategy for optimization of output power of a DFIG wind turbine
    Abedinzadeh, Taller
    Ehsan, Mehdi
    Afsharirad, Hadi
    Nazaraliloo, Mohammad
    [J]. INTERNATIONAL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS & ELECTROMOTION JOINT CONFERENCE, 2011, : 69 - 72