Mechanical Stability Influenced by Assembly Errors of a 0.5 T Mobile MRI Superconducting Magnet

被引:0
|
作者
Yao, Lianhao [1 ]
Qu, Hongyi [2 ]
Wang, Hui [2 ]
Wu, Huafang [3 ]
Liu, Jianhua [2 ]
机构
[1] Nanchang Univ, Adv Mfg Sch, Nanchang 330031, Peoples R China
[2] Chinese Acad Sci, Inst Elect Engn, Beijing 100190, Peoples R China
[3] Chinese Acad Sci, Ganjiang Innovat Acad, Ganzhou 341000, Peoples R China
关键词
Superconducting magnets; Assembly; Stress; Magnetic resonance imaging; Parallel processing; Electromagnetic forces; Magnetomechanical effects; Superconducting magnet structure; mobile MRI; assembly error; electromagnetic force; SYSTEM; FIELD;
D O I
10.1109/TASC.2024.3420320
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Mobile MRI makes it easier to perform MRI in settings with limited resources, which improves imaging accessibility in a greater range of contexts. We present a design for an open superconducting magnet structure that is lightweight and specifically suited for mobile MRI systems in order to further the development of MRI technology. Additionally, based on superconducting magnet manufacturing and assembly tolerance requirements and engineering experience, this study parameterizes the assembly errors of large-gap superconducting magnets, including parallelism errors and translation errors. The comparative simulation analysis revealed that certain areas of superconducting magnet will experience an increase in equivalent stress due to assembly errors. Specifically, the stress increase was particularly pronounced at the junctures between the support structure and both the upper and lower support plates, as well as at the barrel and support plate junction's annular area, where tension fluctuations were noticeable. In contrast, equivalent stress changes in other areas of the magnet were not obvious, indicating a low sensitivity to assembly errors in these areas. The outcomes of this study provide a reference for the design and optimization of lightweight and open superconducting magnet structures, contributing to the safety and reliability of mobile MRI systems.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [41] A Novel Design Method of Passive Shimming for 0.7-T Biplanar Superconducting MRI Magnet
    Zhu, Xuchen
    Wang, Houshen
    Wang, Hui
    Li, Yi
    Fang, Youtong
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (07)
  • [42] High-power cold diodes for the protection of a 1.5 T superconducting MRI magnet system
    Soni, Vijay
    Gupta, Arvind
    Kar, Soumen
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2022, 37 (08)
  • [43] Globally Optimal Superconducting Homogeneous Magnet Design for an Asymmetric 3.0 T Head MRI Scanner
    Ni, Zhipeng
    Hu, Geli
    Wang, Qiuliang
    Yan, Luguang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (03)
  • [44] Mechanical stability of a high-T-c superconducting levitation system
    Sugiura, T
    Tashiro, M
    Uematsu, Y
    Yoshizawa, M
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) : 386 - 389
  • [45] A SUPERCONDUCTING 2.5-T HIGH-ACCURACY SOLENOID AND A LARGE 0.5-T DIPOLE MAGNET FOR THE SMC TARGET
    DAEL, A
    CACAUT, D
    DESPORTES, H
    DUTHIL, R
    GALLET, B
    KIRCHER, F
    LESMOND, C
    PABOT, Y
    THINEL, J
    IEEE TRANSACTIONS ON MAGNETICS, 1992, 28 (01) : 560 - 563
  • [46] Mechanical Behavior Analysis of Model Coil for the 40-T Hybrid Magnet Superconducting Outsert
    Zhu, J. W.
    Pan, Y. N.
    Chen, W. G.
    Tan, Y. F.
    Wang, F. T.
    Chen, Z. M.
    Chen, Z. Y.
    He, P.
    Ren, Y.
    Kuang, G. L.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 628 - 631
  • [47] Preliminary Mechanical Analysis of a 9.4-T Whole-Body MRI Magnet
    Li, Lankai
    Cheng, Junsheng
    Ni, Zhipeng
    Wang, Housheng
    Dai, Yinming
    Wang, Qiuliang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (03)
  • [48] Harmonic analysis and optimization for closed-loop superconducting shim coils of 7 T MRI magnet
    Lin, Zijie
    Zhang, Zhan
    Li, Jiaxin
    Gao, Zhaoyao
    Chu, Zhenyu
    Liu, Yongsuo
    Zhang, Panfeng
    Wu, Leping
    Zhou, Chao
    MEDICAL PHYSICS, 2025,
  • [49] Electromagnetic Design of 1.0-T Ultrashort-Cavity Intraoperative Head MRI Superconducting Magnet
    Zhang, Qing
    Xie, Yuchong
    Wang, Pingping
    Liu, Zhengrong
    Du, Huiyu
    Huang, Xiaoyan
    Mo, Lei
    Chen, Lin
    Zhou, Yufu
    Qiu, Bensheng
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2025, 35 (02)
  • [50] The Application of Accurate Calculation of Magnetic Field Intensity in 1.5-T Superconducting MRI Magnet Design
    Feng, Zhongkui
    Li, Lankai
    Gao, Chunjie
    Zhu, Guang
    Li, Yi
    Li, Xian
    Dai, Yinming
    Wang, Qiuliang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (06)