Advanced frequency control schemes and technical analysis for large-scale PEM and Alkaline electrolyzer plants in renewable-based power systems

被引:2
|
作者
Phan, Long Van [1 ,2 ]
Nguyen-Dinh, Nghia Phu [1 ]
Nguyen, Khai Manh [3 ]
Nguyen-Duc, Tuyen [1 ,4 ]
机构
[1] Hanoi Univ Sci & Technol, Sch Elect & Elect Engn, Dept Elect Engn, Power Syst & Renewable Energy Lab, Hanoi 11615, Vietnam
[2] ABL Grp, OWC, Ho Chi Minh 700000, Vietnam
[3] VinUniversity, Coll Engn & Comp Sci, Hanoi, Vietnam
[4] Shibaura Inst Technol, Dept Elect Engn, Tokyo 1358548, Japan
关键词
Frequency regulation ancillary services; Hydrogen; Alkaline electrolyzer; PEM electrolyzer; Wind power; HYDROGEN; ELECTRICITY; SUPPORT; STORAGE; DESIGN;
D O I
10.1016/j.ijhydene.2024.09.360
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Integrating electrolyzers into power systems can significantly contribute to sustainable energy via the generation of green hydrogen while also enhancing frequency stability through effective regulation of the electrolyzers' operating power. This study gives a comprehensive analysis of large-scale electrolyzer plants when providing frequency support to power systems. First, the authors present a model predictive control (MPC)-based secondary frequency controller, combined with a droop controller as the primary frequency controller and a virtual inertia controller. Additionally, the study introduces a universal system frequency response (U-SFR) modeling approach that enables high accuracy, low computation burden, and reduced initial parameters as a testbed. Finally, an in-depth analysis is conducted, focusing on different technical aspects of large-scale electrolyzer plants when providing frequency support services. Case studies integrating PEM and Alkaline electrolyzers into the modified IEEE 39-bus system with over 50% wind power penetration are conducted. It is found that the proposed U-SFR model achieves high accuracy with lower computational time compared to detailed physical models. Additionally, model predictive controllers improve frequency quality more effectively than PID and PID-FLC methods. PEM electrolyzers are found to be more efficient in providing grid frequency support than alkaline electrolyzers due to their technical characteristics. Finally, smaller hydrogen tanks may frequently breach storage constraints, negatively impacting the system's frequency response capability.
引用
收藏
页码:1354 / 1367
页数:14
相关论文
共 50 条
  • [41] Critic-only online adaptive learning based decentralized control schemes for nonlinear large-scale systems
    Jiang, He
    Zhao, Yan
    Xie, Xiangpeng
    Wei, Mofan
    OPTIMAL CONTROL APPLICATIONS & METHODS, 2023, 44 (03): : 1412 - 1424
  • [42] Small-Signal Stability Analysis for Large-Scale Power Electronics- Based Power Systems
    Qiao, Liang
    Xue, Yaosuo
    Kong, Le
    Wang, Fei
    Nupur
    IEEE OPEN ACCESS JOURNAL OF POWER AND ENERGY, 2024, 11 : 280 - 292
  • [43] A survey on analysis on low frequency oscillation in large-scale interconnected power grid and its control measures
    Song, Dunwen
    Yang, Xuetao
    Ding, Qiaolin
    Ma, Shiying
    Li, Baiqing
    Wang, Qing
    Dianwang Jishu/Power System Technology, 2011, 35 (10): : 22 - 28
  • [44] A review on wide-area damping control to restrain inter-area low frequency oscillation for large-scale power systems with increasing renewable generation
    Zhang, Xinran
    Lu, Chao
    Liu, Shichao
    Wang, Xiaoyu
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 57 : 45 - 58
  • [45] Clustering-Based Coordinated Control of Large-Scale Wind Farm for Power System Frequency Support
    Ma, Shaokang
    Geng, Hua
    Yang, Geng
    Pal, Bikash C.
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2018, 9 (04) : 1555 - 1564
  • [46] Matching Based Formation Control and Analysis of Large-Scale Multi-Agent Systems
    Yu, Hongjun
    Shi, Peng
    Lim, Cheng-Chew
    2015 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC 2015): BIG DATA ANALYTICS FOR HUMAN-CENTRIC SYSTEMS, 2015, : 173 - 178
  • [47] Control Strategy of Large-scale DFIG-based Wind Farm for Power Grid Frequency Regulation
    Cao Zhangjie
    Wang Xiaoru
    Tan Jin
    PROCEEDINGS OF THE 31ST CHINESE CONTROL CONFERENCE, 2012, : 6835 - 6840
  • [48] Solar Tracking Control Algorithm Based on Artificial Intelligence Applied to Large-Scale Bifacial Photovoltaic Power Plants
    de Araujo, Jose Vinicius Santos
    de Lucena, Micael Praxedes
    Netto, Ademar Virgolino da Silva
    Gomes, Flavio da Silva Vitorino
    de Oliveira, Kleber Carneiro
    Neto, Jose Mauricio Ramos de Souza
    Cavalcante, Sidneia Lira
    Morales, Luis Roberto Valer
    Villanueva, Juan Moises Mauricio
    de Macedo, Euler Cassio Tavares
    SENSORS, 2024, 24 (12)
  • [49] A distributed-computing-based eigenvalue algorithm for stability analysis of large-scale power systems
    Zhang, Xu
    Shen, Chen
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 1875 - +
  • [50] Modeling and stability analysis methods for investigating subsynchronous control interaction in large-scale wind power systems
    Shair, Jan
    Xie, Xiaorong
    Liu, Wei
    Li, Xuan
    Li, Haozhi
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 135 (135):