Size effect on fire resistance performance of reinforced concrete circular columns under axial compression

被引:0
|
作者
Zhang, Haiyan [1 ,2 ]
Gong, Junlin [2 ]
Wan, Ying [3 ]
Wu, Bo [1 ,2 ]
机构
[1] State Key Laboratory of Subtropical Building and Urban Science, South China University of Technology, Guangzhou,510640, China
[2] School of Civil Engineering and Transportation, South China University of Technology, Guangzhou,510640, China
[3] Central-South Architectural Design Institute Co., Ltd, Wuhan,430061, China
关键词
D O I
10.14006/j.jzjgxb.2023.0559
中图分类号
学科分类号
摘要
Fire resistance
引用
收藏
页码:42 / 53
相关论文
共 50 条
  • [1] Fire resistance studies on circular tubed steel reinforced concrete stub columns subjected to axial compression
    Zhou, Xuhong
    Wang, Weiyong
    Song, Keyan
    Chen, Y. Frank
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 159 : 231 - 244
  • [2] Performance of large circular reinforced concrete columns under compression
    Lee, Tai-Kuang
    Chen, Cheng-Cheng
    Pan, Austin D. E.
    Hwa, Ken
    Ma, Michael J. L.
    MAGAZINE OF CONCRETE RESEARCH, 2013, 65 (08) : 519 - 527
  • [3] Performance of large reinforced concrete columns under axial compression loads
    Lee, Tai-Kuang
    Chen, Cheng-Cheng
    Hwa, Ken
    Pan, Austin D. E.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2014, 167 (05) : 300 - 311
  • [4] Behavior of Circular Hollow Steel-Reinforced Concrete Columns under Axial Compression
    Wei, Qiuyu
    Ren, Qingxin
    Wang, Qinghe
    Zhang, Yannian
    APPLIED SCIENCES-BASEL, 2024, 14 (11):
  • [5] Analytical Behavior of Square Reinforced Concrete Stub Columns under Overall Fire and Axial Compression
    Zheng, Yongqian
    Zhuang, Jinping
    ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 2709 - 2712
  • [6] Calculation of circular reinforced concrete long columns confined with CFRP sheets under axial compression
    Ren, Qingxin
    Li, Shunqun
    Liu, Yanhua
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON HEALTH MONITORING OF STRUCTURE, MATERIALS AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 930 - +
  • [7] Size effect of circular concrete-filled stainless steel tubular short columns under axial compression
    Liu, Xiaolong
    Wang, Senping
    Yuan, Bo
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2023, 32 (01):
  • [8] Size effect of square steel tube and sandwiched concrete jacketed circular RC columns under axial compression
    Zhao, Xiaobo
    Liang, Hongjun
    Lu, Yiyan
    Zhao, Pengtuan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 166
  • [9] Size effect law for nominal strength of stirrup-confined circular concrete columns under axial compression
    Jin L.
    Li P.
    Du X.-L.
    Li D.
    Du, Xiu-Li (duxiuli@bjut.edu.cn), 1600, Tsinghua University (37): : 64 - 73
  • [10] Behavior of Circular Reinforced Concrete Columns Under Fire Conditions
    Raut, Nikhil
    Kodur, Venkatesh
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2012, 3 (01) : 37 - 55