Fire resistance studies on circular tubed steel reinforced concrete stub columns subjected to axial compression

被引:16
|
作者
Zhou, Xuhong [1 ,2 ]
Wang, Weiyong [1 ,2 ]
Song, Keyan [1 ]
Chen, Y. Frank [1 ,2 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Minist Educ, Key Lab New Technol Construct Cities Mt Area, Chongqing 400045, Peoples R China
关键词
Circular tubed steel reinforced concrete stub columns; Fire resistance; Finite element analysis; Simplified method; BEHAVIOR;
D O I
10.1016/j.jcsr.2019.04.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A series of fire tests on eight circular tubed steel reinforced concrete (CTSRC) stub columns subjected to axial loading are presented in this paper. The influences of load level and steel tube thickness on the fire resistance of the CTSRC stub columns were investigated. Two similar specimens were tested with the same test scenario to obtain more reasonable data. The temperatures in steel and concrete, axial displacement, fire resistance, and failure mode were recorded and discussed. The test results show that the load level has a great influence on the fire resistance of CTSRC stub columns. The steel tube thickness has a significant influence on the fire resistance of CTSRC stub columns when subjected to a higher load level. Thermal and structural finite element (FE) models were developed to analyze the temperature distributions and fire responses of CTSRC stub columns by employing the program ABAQUS. These developed models were validated by the test data. Extensive parametric studies were carried out by using the FE method to investigate the influences of key factors on the temperature distributions and fire resistances of CTSRC stub columns. The factors considered for thermal analysis include cross-sectional dimension, steel tube thickness, and concrete type, while the factors considered for structural analysis include load ratio, cross-sectional dimension, steel tube thickness, concrete strength, and steel strength. The parametric studies indicate that the cross-sectional dimension has a more significant influence than the steel tube thickness on the temperature magnitudes of CTSRC stub columns. The load ratio, cross-sectional dimension, and steel tube thickness have more significant influence than concrete strength on the fire resistance of CTSRC stub columns. Based on the results of the parametric studies, a simplified method to predict the steel temperatures and the compressive load bearing capacities of CTSRC stub columns exposed to fire is proposed. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:231 / 244
页数:14
相关论文
共 50 条
  • [1] Axial compression behaviour and design of square tubed steel reinforced-concrete stub columns after fire exposure
    Yang, Dongdong
    Liu, Faqi
    Yang, Hua
    Wang, Fengqin
    Peng, Kang
    Wang, Xizhen
    [J]. THIN-WALLED STRUCTURES, 2023, 192
  • [2] Axial compression behaviour and design of square tubed steel reinforced-concrete stub columns after fire exposure
    Yang, Dongdong
    Liu, Faqi
    Yang, Hua
    Wang, Fengqin
    Peng, Kang
    Wang, Xizhen
    [J]. THIN-WALLED STRUCTURES, 2023, 192
  • [3] Experimental and numerical study on fire resistance of tubed steel-reinforced concrete stub columns under eccentric compression
    Liu, Jiepeng
    Xing, Yonghui
    Song, Keyan
    Wang, Weiyong
    [J]. STEEL AND COMPOSITE STRUCTURES, 2021, 41 (04): : 549 - 566
  • [4] Circular Inclined Concrete-Filled Steel Tubular Stub Columns subjected to Axial Compression
    Ren, Qingxin
    Guo, Junfeng
    Jia, Lianguang
    Yu, Shuzhai
    [J]. ADVANCED RESEARCH ON MATERIAL ENGINEERING, ARCHITECTURAL ENGINEERING AND INFORMATIZATION, 2012, 366 : 3 - 6
  • [5] Axial behaviour of circular steel tubed concrete stub columns confined by CFRP materials
    Liu, Jie-Peng
    Xu, Tian-Xiang
    Wang, Yu-Hang
    Guo, Ying
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2018, 168 : 221 - 231
  • [6] Behavior of short circular tubed-reinforced-concrete columns subjected to eccentric compression
    Wang, Xuanding
    Liu, Jiepeng
    Zhang, Sumei
    [J]. ENGINEERING STRUCTURES, 2015, 105 : 77 - 86
  • [7] Axial load behavior and strength of tubed steel reinforced-concrete (SRC) stub columns
    Qi, Hongtuo
    Guo, Lanhui
    Liu, Jiepeng
    Gan, Dan
    Zhang, Sumei
    [J]. THIN-WALLED STRUCTURES, 2011, 49 (09) : 1141 - 1150
  • [8] Circular concrete-encased concrete-filled steel tube (CFST) stub columns subjected to axial compression
    Li, Yong-Jin
    Han, Lin-Hai
    Xu, Wu
    Tao, Zhong
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2016, 68 (19) : 995 - 1010
  • [9] Axial loading behavior of circular tubed-steel-reinforced-concrete stub columns with high diameter-to-thickness ratio
    Zhou, Xuhong
    Wang, Xuanding
    Gan, Dan
    Liu, Jiepeng
    [J]. Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 : 240 - 246
  • [10] Axial compressive behavior and confinement mechanism of circular FRP-steel tubed concrete stub columns
    Wang, Yanlei
    Chen, Guipeng
    Wan, Baolin
    Han, Baoguo
    Ran, Jianghua
    [J]. COMPOSITE STRUCTURES, 2021, 256