Wind-driven and buoyancy effects for modeling natural ventilation in buildings at urban scale

被引:0
|
作者
Santantonio, Silvia [1 ]
Dell'Edera, Oronzo [2 ]
Moscoloni, Claudio [2 ,3 ]
Bertani, Cristina [1 ]
Bracco, Giovanni [2 ]
Mutani, Guglielmina [1 ]
机构
[1] DENERG Politecn Torino, Corso Duca Abruzzi 24, I-10129 Turin, Italy
[2] DIMEAS Politecn Torino, corso Duca Abruzzi 24, I-10129 Turin, Italy
[3] Univ Sch Adv Studies IUSS Pavia, piazza Vittoria 15, I-27100 Pavia, Italy
关键词
Natural ventilation; Leakages; Wind driven effect; Thermal buoyancy effect; Air changes per hour; Lumped parameter model; Numerical method; CFD; Pressure coefficient Cp; Urban canyon; Urban building energy modeling; CFD; SIMULATION; COMFORT; CANYON; FLOWS;
D O I
10.1007/s12053-024-10266-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work proposes a new model to evaluate the air changes per hour (ach) due to natural infiltrations in buildings. This modeling already exists at building scale, but the new model will implement the hourly ventilation load in a physical-based modeling for space heating and cooling in buildings at urban scale. The proposed improvement considers the wind and buoyancy effects in the calculation of hourly achs in a high-density urban context. A three-zone air flow lumped modeling is applied to describe the air flow in buildings; the air flow rate due to infiltrations is calculated depending only on leakages' characteristics and pressure variations in various climate conditions. The non-linear equations system of mass and energy conservation is solved by an iterative procedure using the Newton-Raphson numerical method. Besides, two different methodologies are compared to evaluate the external dynamic and static pressure conditions on building fa & ccedil;ades: experimental values (pressure coefficients Cp) and CFD simulations. For the latter, the air flow field in the urban canyons is described by the windy conditions and by imposing a temperature gradient due to solar irradiation between the windward and leeward facades. This methodology is applied to three urban canyons in Turin, with typical aspect ratios and orientations for some local climate conditions considering both heating and cooling seasons. Comparing the results of hourly ach obtained from the Cp method, the CFD technique allows to modulate the ach considering the impact of the canyon dimension, wind and buoyancy effect of non-isothermal condition, in varying the wind speed on the fa & ccedil;ades of buildings for different scenarios. It also overcomes the limit of field of applications of Cp, especially in high-density built urban environments. The encouraging results of this work will lead to future developments of the three-zone lumped model and its numerical solution techniques.
引用
收藏
页数:32
相关论文
共 50 条
  • [41] Effects of Porosity on Wind Driven Natural Cross Ventilation of a Full Scale Building
    Bangalee, M.Z.I.
    Lin, S.Y.
    Miau, J.J.
    Journal of the Chinese Society of Mechanical Engineers, Transactions of the Chinese Institute of Engineers, Series C/Chung-Kuo Chi Hsueh Kung Ch'eng Hsuebo Pao, 2016, 37 (04): : 305 - 313
  • [42] Wind-driven pumping flow ventilation of highrise buildings: Effects of upstream building arrangements and opening area ratios
    Zhong, Huai-Yu
    Jing, Yi
    Sun, Yang
    Kikumoto, Hideki
    Zhao, Fu-Yun
    Li, Yuguo
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 722
  • [43] Comparison of Wind-Driven Natural Ventilation for Different Windows in a Room with a Single Opening
    Ruan, Fang
    Li, Nianping
    INTERNATIONAL JOURNAL OF VENTILATION, 2012, 11 (02) : 193 - 203
  • [44] A MODEL STUDY OF WIND-DRIVEN AND BUOYANCY-DRIVEN COASTAL CIRCULATION
    IKEDA, M
    JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 1988, 93 (C5): : 5078 - 5092
  • [45] Experimental and numerical evaluation of wind-driven natural ventilation of a curved roof for various wind angles
    Esfeh, M. Kazemi
    Sohankar, A.
    Shahsavari, A. R.
    Rastan, M. R.
    Ghodrat, M.
    Nili, M.
    BUILDING AND ENVIRONMENT, 2021, 205
  • [46] Buoyancy-driven single-sided natural ventilation in buildings with large openings
    Jiang, Y
    Chen, QY
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (06) : 973 - 988
  • [47] Simulation of buoyancy-driven natural ventilation of buildings-Impact of computational domain
    Gan, Guohui
    ENERGY AND BUILDINGS, 2010, 42 (08) : 1290 - 1300
  • [48] Impact of aperture separation on wind-driven single-sided natural ventilation
    Daish, N. C.
    da Graca, G. Carrilho
    Linden, P. F.
    Banks, D.
    BUILDING AND ENVIRONMENT, 2016, 108 : 122 - 134
  • [49] Numerical simulation of wind-driven natural ventilation: Effects of loggia and facade porosity on air change rate
    Cui, Shuqing
    Stabat, Pascal
    Marchio, Dominique
    BUILDING AND ENVIRONMENT, 2016, 106 : 131 - 142
  • [50] On the accuracy of wind-driven rain measurements on buildings
    Blocken, Bert
    Carmeliet, Jan
    BUILDING AND ENVIRONMENT, 2006, 41 (12) : 1798 - 1810