TiO2 coatings doped with MoS2 nanoparticles using plasma electrolytic oxidation on Ti-6Al-4V alloy: Application for enhanced and functional bio-implant surface

被引:4
|
作者
Nisar, Sidra Sadaf [1 ,2 ]
Choe, Han-Cheol [1 ,2 ]
机构
[1] Chosun Univ, Coll Dent, Dept Dent Mat, Adv Funct Surface & Biomat Res Lab, Gwangju 61452, South Korea
[2] Chosun Univ, Coll Dent, Convergence Res Ctr Treatment Oral Soft Tissue Dis, Gwangju 61452, South Korea
基金
新加坡国家研究基金会;
关键词
Plasma electrolytic oxidation; Ti-6Al-4V; TiO2; MoS2; nanoparticles; Biological behaviors; HYDROXYAPATITE; PATHWAYS; ADHESION; HYDROGEN; SHAPE;
D O I
10.1016/j.jmrt.2024.09.185
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The focus of this study was to examine the surface, mechanical, corrosion, and bioactive characteristics of TiO2 coatings doped with different grams of nanoparticles of MoS2, which were fabricated using the plasma electrolytic oxidation (PEO) technique, and the structure, morphology, surface characteristics, and corrosion resistance of MoS2 and TiO2 coatings were assessed. The coatings were fabricated on the Ti-6Al-4V alloy substrate using a PEO setup, with varying concentrations of MoS2 nanoparticles incorporated into the electrolyte solution. FESEM, XRD, and AFM were utilized to analyze the surface characteristics of the coatings. Also, PDP and AC impedance tests were done to check corrosion properties. Raman analysis, XPS, and cell tests were also done. The findings demonstrated that incorporating MoS2 nanoparticles resulted in creating a composite coating characterized by adequately increased surface energy, wettability, and improved adhesion to the substrate. The FESEM analysis revealed a uniform dispersion of MoS2 throughout the TiO2 matrix forming a homogeneous and compact coating structure and also doping inside the PEO pores. XRD analysis confirmed the presence of TiO2, and the addition of MoS2 nanoparticles further improved the crystallinity of the TiO2 coating. AFM measurements demonstrated a slight increase in surface roughness and an increase in surface hardness upon the inclusion of MoS2. Compared to pure TiO2, the TiO2 coating doped with MoS2 displayed superior electrochemical corrosion resistance and cell proliferation properties. Alazirin staining, ALP, and mRNA activity showed that lower MoS2 content such as P-2MoS(2) to P-6MoS(2) showed better cellular differentiation properties.
引用
收藏
页码:2035 / 2056
页数:22
相关论文
共 50 条
  • [41] Characterisation of oxide films produced by plasma electrolytic oxidation of a Ti-6Al-4V alloy
    Yerokhin, AL
    Nie, X
    Leyland, A
    Matthews, A
    SURFACE & COATINGS TECHNOLOGY, 2000, 130 (2-3): : 195 - 206
  • [42] Bioactive coatings on Ti6Al4V alloy formed by plasma electrolytic oxidation
    Durdu, Salih
    Usta, Metin
    Berkem, Ali Sabri
    SURFACE & COATINGS TECHNOLOGY, 2016, 301 : 85 - 93
  • [43] Evaluation of corrosion and tribocorrosion of plasma electrolytic oxidation treated Ti-6Al-4V alloy
    Jazi, M. R. Garsivaz
    Golozar, M. A.
    Raeissi, K.
    Fazel, M.
    SURFACE & COATINGS TECHNOLOGY, 2014, 244 : 29 - 36
  • [44] Tribological properties of laser surface textured and plasma electrolytic oxidation duplex-treated Ti6Al4V alloy deposited with MoS2 film
    Qin, Yongkun
    Xiong, Dangsheng
    Li, Jianliang
    SURFACE & COATINGS TECHNOLOGY, 2015, 269 : 266 - 272
  • [45] FABRICATION AND CHARACTERIZATION OF TiO2 FILMS ON Ti-6Al-4V BY ANODIC OXIDATION
    Vera, Maria L.
    Ares, Alicia E.
    Rosenberger, Mario R.
    Lamas, Diego G.
    Schvezov, Carlos E.
    TMS 2010 139TH ANNUAL MEETING & EXHIBITION - SUPPLEMENTAL PROCEEDINGS, VOL 2: MATERIALS CHARACTERIZATION, COMPUTATION AND MODELING AND ENERGY, 2010, : 625 - +
  • [46] Coatings of Bioactive TiO2 Films on TI6AL4V Alloy by Micro Arc Oxidation
    Ayday, A.
    ACTA PHYSICA POLONICA A, 2018, 134 (01) : 412 - 414
  • [47] Formation of Ca, P, and Zn-doped ZrO2/TiO2 coating layer via plasma electrolytic oxidation and magnetic sputtering: Improving surface characteristics and biocompatibility of Ti-6Al-4V alloy
    Nisar, Sidra Sadaf
    Arun, S.
    Toan, Nguyen Khanh
    Ahn, Sang -Gun
    Choe, Han-Cheol
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2024, 31 : 1282 - 1303
  • [48] In vitro assessment of plasma-sprayed reinforced hydroxyapatite coatings deposited on Ti6Al4V alloy for bio-implant applications
    Singh, Jarnail
    Chatha, Sukhpal Singh
    Singh, Hazoor
    JOURNAL OF MATERIALS RESEARCH, 2022, 37 (16) : 2623 - 2634
  • [49] In vitro assessment of plasma-sprayed reinforced hydroxyapatite coatings deposited on Ti6Al4V alloy for bio-implant applications
    Jarnail Singh
    Sukhpal Singh Chatha
    Hazoor Singh
    Journal of Materials Research, 2022, 37 : 2623 - 2634
  • [50] Response of boride coating on the Ti-6Al-4V alloy to corrosion and fretting corrosion behavior in Ringer's solution for bio-implant application
    Bose, Sivakumar
    Pathak, Lokesh Chandra
    Singh, Raghuvir
    APPLIED SURFACE SCIENCE, 2018, 433 : 1158 - 1174