Industry 4.0 drives the demand for cost-efficient and reliable process data and condition monitoring. Therefore, visualizing the state of tribological contacts becomes important, as they are regularly found in the center of many applications. Utilizing rolling element bearings as sensors and monitoring their health by the electrical impedance method are promising approaches as it allows, e.g., load sensing and detection of bearing failures. The impedance cannot be measured directly, but there are various methods available. This paper discusses advantages and disadvantages and suggests the AC Wheatstone bridge as a reliable way of measuring impedances with low phase angles at sampling rates in the kHz range. The corresponding equations are introduced, a simulation built, an uncertainty mode and effects analysis carried out and sample measurement results of real rolling elements shown. It can be demonstrated that the AC Wheatstone bridge meets the proposed requirements for sensory utilization and condition monitoring when the bearing is operated in the hydrodynamic regime.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Method for AC powerline impedance measurement
    Gasperi, Michael L.
    Jensen, David L.
    Rollay, David T.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (04) : 1034 - 1037
  • [42] TEMPERATURE MEASUREMENT BASED ON VISCOUS FLOW OF GAS IN A WHEATSTONE-BRIDGE NETWORK
    HOGE, HJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1961, 32 (01): : 1 - &
  • [43] Practical Implementation of the Sensory Utilization of Rolling Bearing Impedance Measurement: A Case Study in Machine Tool Spindle Bearings
    Fett, Michel
    Puchtler, Steffen
    Zaiat, Anatoly
    Bock, Moritz
    Melzer, Christiane
    Hoffmann, Felix
    Weigold, Matthias
    Kirchner, Eckhard
    TRIBOLOGY TRANSACTIONS, 2024, 67 (04) : 691 - 701
  • [44] Design of Wheatstone bridge based thermistor signal conditioning circuit for temperature measurement
    Ibrahim O.
    Hassan S.M.
    Abdulkarim A.
    Akorede M.F.
    Amuda S.A.
    Journal of Engineering Science and Technology Review, 2019, 12 (01) : 12 - 17
  • [45] Evaluation of NMIJ Traveling Dual Source Bridge Using NIST Adapted Wheatstone Bridge
    Oe, T.
    Payagala, S.
    Jarrett, D. G.
    Kaneko, N-H
    2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [46] A SELF-BALANCING PNEUMATIC WHEATSTONE BRIDGE FOR SURFACE-ROUGHNESS MEASUREMENT
    TANNER, LH
    WEAR, 1982, 83 (01) : 37 - 47
  • [47] DIGITAL AC BRIDGE AS AN IMPEDANCE TO FREQUENCY CONVERTER.
    Schollmeyer, Hartmut
    1600, (IM-34):
  • [48] A DIGITAL AC BRIDGE AS AN IMPEDANCE TO FREQUENCY-CONVERTER
    SCHOLLMEYER, H
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1985, 34 (03) : 389 - 392
  • [49] ANALYSIS, DESIGN, AND IMPLEMENTATION OF AN AC BRIDGE FOR IMPEDANCE MEASUREMENTS
    AWAD, SS
    NARASIMHAMURTHI, N
    WARD, WH
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1994, 43 (06) : 894 - 899
  • [50] SEMIBALANCED AC BRIDGE CIRCUIT FOR MEASURING AN IMPEDANCE COMPONENT
    VIZIR, YV
    MEASUREMENT TECHNIQUES-USSR, 1966, (08): : 1042 - &