IEEE ACCESS | 2024年 / 12卷
关键词
Depth sensor; fitzpatrick scale; laser interferometer; respiratory rate; time-of-flight; BREATHING RATE; PHOTOPLETHYSMOGRAM; ELECTROCARDIOGRAM; FRAMEWORK; CAMERA;
D O I
10.1109/ACCESS.2024.3484992
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Depth measurements are becoming increasingly popular in many fields, particularly biomedical applications. Existing time-of-flight cameras suffer from low spatial resolution due to additional processing at the sensor level. In this paper, we propose a low-cost, off-the-shelf, and non-contact measurement system based on an indirect time-of-flight sensor for respiratory rate measurements. To this end, the performance of the single depth sensor in short-range distance measurements has been examined using a ground truth laser interferometer. Tissue-simulating abdominal wall surfaces were used to validate the accuracy of the proposed device. The simulated surfaces had six different reflectance levels, corresponding to the standard Fitzpatrick scale of human skin color. Our results show excellent agreement between the expected and extracted values of displacement and vibration Frequency using a fast Fourier transform of the time-varying displacements. The clinical performance of the proposed sensor was verified by thirty human respiratory rate measurements. It showed an overall mean absolute error (MAE) of 0.43 breaths/min. Respiratory rate measurements also showed a strong and positive relationship with the clinical reference method (r =0.99, p <0.001) and Bland-Altman analysis revealed a bias of -0.18 breaths/min. Besides, the accuracy of the sensor is well suited, on average, for clinical measurements over the skin reflectivity range of 20-80%. The findings of this work provide a potentially simple, low-cost solution for remote displacement and vibration measurement, making it a promising tool for remote health monitoring in clinical settings.
引用
收藏
页码:156442 / 156457
页数:16
相关论文
共 50 条
  • [31] Optical aspects of a fibre-optic sensor for respiratory rate monitoring
    Pettersson, H
    Stenow, END
    Cai, H
    Oberg, PA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (06) : 448 - 452
  • [32] Femtosecond optical time-of-flight measurement of the electron velocity in GaN
    Wraback, M
    Shen, H
    Carrano, JC
    Li, T
    Campbell, JC
    ULTRAFAST PHENOMENA XII, 2001, 66 : 366 - 368
  • [33] Noncontact Respiratory Measurement of Volume Change Using Depth Camera
    Yu, Meng-Chieh
    Liou, Jia-Ling
    Kuo, Shuenn-Wen
    Lee, Ming-Sui
    Hung, Yi-Ping
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2371 - 2374
  • [34] Non-contact Breathing Rate Detection Based on Time of Flight Sensor
    Yang, Chengxu
    Huang, Xinxin
    Zheng, Yu
    Xie, Yufei
    Duan, Xiaohui
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 7284 - 7287
  • [35] Toward Respiratory Assessment Using Depth Measurements from a Time-of-Flight Sensor
    Sharp, Charles
    Soleimani, Vahid
    Hannuna, Sion
    Camplani, Massimo
    Damen, Dima
    Viner, Jason
    Mirmehdi, Majid
    Dodd, James W.
    FRONTIERS IN PHYSIOLOGY, 2017, 8
  • [36] Unconstrained Measurement of Heart Rate Considering Harmonics of a Respiratory Signal by Tactile Sensor
    Matsuo, Kazuya
    Mukai, Toshiharu
    Guo, Shijie
    PROCEEDINGS OF THE 2021 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS (ICAROB 2021), 2021, : P90 - P90
  • [37] METHOD OF NONCONTACT OPTICAL MEASUREMENT OF THE DIAMETER OF TRANSPARENT TUBES
    PILIPOVICH, VA
    ESMAN, AK
    KULESHOV, VK
    DUBROVSKII, VP
    MEASUREMENT TECHNIQUES USSR, 1990, 33 (06): : 546 - 548
  • [38] Noncontact all-optical measurement of corneal elasticity
    Li, Chunhui
    Guan, G.
    Huang, Z.
    Johnstone, M.
    Wang, R. K.
    OPTICS LETTERS, 2012, 37 (10) : 1625 - 1627
  • [39] Measurement of respiratory rate with high-resolution accelerometer and EMFit pressure sensor
    Reinvuo, Tuomas
    Hannula, Manne
    Sorvoja, Hannu
    Alasaarela, Esko
    Myllyla, Risto
    PROCEEDINGS OF THE 2006 IEEE SENSORS APPLICATIONS SYMPOSIUM, 2006, : 192 - 195
  • [40] A differential capacitive electrical field sensor array for contactless measurement of respiratory rate
    Wartzek, T.
    Weyer, S.
    Leonhardt, S.
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (10) : 1575 - 1590