Design analysis and motion capture verification of a flexible bionic single finger

被引:0
|
作者
Hou, Ruilin [1 ]
Zhang, Xiaotong [1 ]
Wang, Yindi [1 ]
Qin, Xue [1 ]
Wang, Yangwei [1 ]
机构
[1] Northeast Forestry Univ, Coll Mech & Elect Engn, Harbin 150040, Peoples R China
基金
中国国家自然科学基金;
关键词
Flexion movement; Finger kinematics; DIP and PIP; Bionic single-finger mechanism; Vicon motion capture; HAND;
D O I
10.1007/s11370-024-00565-y
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
This study obtains biological inspiration from the human single-finger movement mechanism, deeply discusses the flexion movement characteristics of bionic single finger and compares it with the finger flexion and extension movement of real subjects. By simplifying the single-finger structure into a line-drive linkage mechanism, the continuous pose state underline-drive action is obtained. The coupling relationship between DIP and PIP was obtained by using a high-speed camera to measure the flexion and extension motion of real human fingers, and the synergistic action between the designed bionic single-finger phalangeal joints was required to restore the real biological motion law. The Vicon motion capture system was used to compare the flexion and extension motion of the bionic single-finger designed in this paper with the real finger. The high accuracy of the recorded motion data not only helps to understand the characteristics of the single-finger motion but also provides useful information for medical treatment, rehabilitation and human-computer interaction. The results show that the flexion movement of bionic single finger is consistent with the real movement of human finger, which verifies the accuracy of the theory and the practicability of the structure. This study provides useful guidance and direction for rehabilitation robot, biology and so on.
引用
收藏
页码:1163 / 1173
页数:11
相关论文
共 50 条
  • [31] Experimental verification of design automation methods for robotic finger
    Honarpardaz, M.
    Tarkian, M.
    Olvander, J.
    Feng, X.
    ROBOTICS AND AUTONOMOUS SYSTEMS, 2017, 94 : 89 - 101
  • [32] Detection and Analysis of Bionic Motion Pose of Single Leg and Hip Joint Based on Random Process
    Zhang, Peng
    Baek, Seung-soo
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [33] Control Design and Implementation of Robotic Massage Based on Finger Pressing Motion Analysis
    Harada, Naoya
    Akiduki, Takuma
    Kitazaki, Michiteru
    Tasaki, Ryosuke
    2023 8TH INTERNATIONAL CONFERENCE ON CONTROL AND ROBOTICS ENGINEERING, ICCRE, 2023, : 250 - 253
  • [34] A BIONIC DESIGN WITH WING STRUCTURES TO ASSIST FLEXIBLE MICROELECTRODE IMPLANTATION
    Zhang, Leihan
    Wang, Yi
    Cai, Yi
    PROCEEDINGS OF ASME 2023 18TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE, MSEC2023, VOL 1, 2023,
  • [35] Bionic design and verification of high-precision machine tool structures
    Suna Yan
    Baotong Li
    Jun Hong
    The International Journal of Advanced Manufacturing Technology, 2015, 81 : 73 - 85
  • [36] Bionic design and verification of high-precision machine tool structures
    Li, Baotong (baotong.me@mail.xjtu.edu.cn), 1600, Springer London (81): : 1 - 4
  • [37] Bionic design and verification of high-precision machine tool structures
    Yan, Suna
    Li, Baotong
    Hong, Jun
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2015, 81 (1-4): : 73 - 85
  • [38] Optimisation and Comparison of Markerless and Marker-Based Motion Capture Methods for Hand and Finger Movement Analysis
    Maggioni, Valentin
    Azevedo-Coste, Christine
    Durand, Sam
    Bailly, Francois
    SENSORS, 2025, 25 (04)
  • [39] Improving Grasping of Bionic Hand by Using Finger Compliance Design and Rapid Prototyping
    Yeghiazarian, Carin
    Balan, Lucian
    MOBILE TECHNOLOGIES AND APPLICATIONS FOR THE INTERNET OF THINGS, 2019, 909 : 3 - 13
  • [40] Measurements of wrist and finger postures: A comparison of goniometric and motion capture techniques
    Cook, James R.
    Baker, Nancy A.
    Cham, Rakie
    Hale, Erin
    Redfern, Mark S.
    JOURNAL OF APPLIED BIOMECHANICS, 2007, 23 (01) : 70 - 78