Modelling of Indoor Air Quality and Thermal Comfort in Passive Buildings Subjected to External Warm Climate Conditions

被引:0
|
作者
Conceicao, Eusebio [1 ,2 ]
Gomes, Joao [3 ]
Conceicao, Maria Ines [4 ]
Conceicao, Margarida [4 ]
Lucio, Maria Manuela [1 ]
Awbi, Hazim [5 ]
机构
[1] Univ Algarve, Fac Ciencias & Tecnol, Campus Gambelas, P-8005139 Faro, Portugal
[2] Dept Engn Mecan, ADAI, Rua Luis Reis St,Polo 2, P-3030788 Coimbra, Portugal
[3] Univ Algarve, Inst Super Engn, Campus Penha, P-8005139 Faro, Portugal
[4] Univ Lisbon, Inst Super Tecn, P-1049001 Lisbon, Portugal
[5] Univ Reading, Sch Built Environm, Reading RG6 6AW, England
关键词
indoor air quality; thermal comfort; passive buildings; numerical simulation; COMMERCIAL BUILDINGS; NATURAL VENTILATION; COOLING STRATEGIES; PERFORMANCE; DESIGN; STATE;
D O I
10.3390/atmos15111282
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Air renewal rate is an important parameter for both indoor air quality and thermal comfort. However, to improve indoor thermal comfort, the air renewal rate to be used, in general, will depend on the outdoor air temperature values. This article presents the modelling of indoor air quality and thermal comfort for occupants of a passive building subject to a climate with warm conditions. The ventilation and shading strategies implemented for the interior spaces are then considered, as well as the use of an underground space for storing cooled air. The indoor air quality is evaluated using the carbon dioxide concentration, and thermal comfort is evaluated using the Predicted Mean Vote index. The geometry of the passive building, with complex topology, is generated using a numerical model. The simulation is performed by Building Thermal Response software, considering the building's geometry and materials, ventilation, and occupancy, among others. The building studied is a circular auditorium. The auditorium is divided into four semi-circular auditoriums and a central circular space, with vertical glazed windows and horizontal shading devices on its entire outer surface. Typical summer conditions existing in a Mediterranean-type environment were considered. In this work, two cases were simulated: in Case 1, the occupation is verified in the central space and the four semi-circular auditoriums and all spaces are considered as one; in Case 2, the occupation is verified only in each semi-circular auditorium and each one works independently. For both cases, three strategies were applied: A, without shading and geothermal devices; B, with a geothermal device and without a shading device; and C, with both shading and geothermal devices. The airflow rate contributes to improving indoor air quality throughout the day and thermal comfort for occupants, especially in the morning. The geothermal and shading devices improve the thermal comfort level, mainly in the afternoon.
引用
收藏
页数:32
相关论文
共 50 条
  • [31] Study of indoor air quality and thermal comfort in offices in Hunan
    Yang, Wei
    Zhang, Guoqiang
    Zhang, Quan
    Journal of Harbin Institute of Technology (New Series), 2007, 14 (SUPPL. 2) : 201 - 203
  • [32] Thermal comfort and Indoor Air Quality assessment in university classrooms
    Papadopoulos, Giannis
    Panaras, Giorgos
    Tolis, Evangelos
    SUSTAINABILITY IN THE BUILT ENVIRONMENT FOR CLIMATE CHANGE MITIGATION (SBE19), 2020, 410
  • [33] Field study of thermal comfort and indoor air quality in gymnasium
    谢慧
    甘晓爱
    马飞
    JournalofCentralSouthUniversityofTechnology, 2009, 16(S1) (S1) : 48 - 54
  • [34] Study of indoor air quality and thermal comfort of public place
    Wang Ye
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 4122 - 4125
  • [35] Field study of thermal comfort and indoor air quality in gymnasium
    谢慧
    甘晓爱
    马飞
    Journal of Central South University, 2009, 16 (S1) : 48 - 54
  • [36] Improving PAQ and comfort conditions in Spanish office buildings with passive climate control
    Orosa, Jose A.
    Baalina, A.
    BUILDING AND ENVIRONMENT, 2009, 44 (03) : 502 - 508
  • [37] Indoor comfort conditions assessment in educational buildings with respect to adaptive comfort standards in European climate zones
    Tagliabue, Lavina Chiara
    Accardo, Daniele
    Kontoleon, Karolos J.
    Ciribini, Angelo Luigi Camillo
    SUSTAINABILITY IN THE BUILT ENVIRONMENT FOR CLIMATE CHANGE MITIGATION (SBE19), 2020, 410
  • [38] Assessing Thermal Comfort and Indoor Air Quality: In an Educational Facility of a Semi-Arid Climate Zone
    Parmaksiz, Kemalettin
    Yesilnacar, Mehmet Irfan
    Karabulut, Abdullah Izzeddin
    ATMOSPHERE, 2025, 16 (01)
  • [39] Interaction between Thermal Comfort, Indoor Air Quality and Ventilation Energy Consumption of Educational Buildings: A Comprehensive Review
    Jia, Lin-Rui
    Han, Jie
    Chen, Xi
    Li, Qing-Yun
    Lee, Chi-Chung
    Fung, Yat-Hei
    BUILDINGS, 2021, 11 (12)
  • [40] Optimization of fresh air conditioning system for indoor thermal comfort and air quality
    Yang, P. (yang_peizhi@csu.edu.cn), 1600, Sila Science, University Mah Mekan Sok, No 24, Trabzon, Turkey (31):