A numerical study on the sustainability and efficiency of deep coaxial borehole heat exchanger systems in the cold region of northeast China

被引:0
|
作者
Ma, Yongfa [1 ,2 ,3 ,4 ,5 ]
Yang, Fengtian [3 ,4 ]
Zhu, Ruijie [3 ]
Zhou, Xuejun [1 ,4 ]
Liu, Guang [1 ,4 ]
Yuan, Lijuan [2 ]
Wang, Xu [1 ,4 ]
Dong, Junling [1 ]
Lü, Honglin [1 ,4 ]
Li, Chang [1 ,4 ]
Zhan, Tao [1 ,6 ]
Su, Bin [6 ]
Xu, Siqi [3 ]
机构
[1] Institute of Ecological Geology Survey and Research of Heilongjiang Province, Harbin,150030, China
[2] Key Laboratory of Shallow Geothermal Energy, Ministry of Natural Resources of the People's Republic of China, Beijing,100195, China
[3] Key Laboratory of Groundwater Resources and Environment, Ministry of Education, Jilin University, Changchun,130021, China
[4] Innovation Base of Cold Region Geothermal Energy Application Technology of Northeast China, Geological Society of China, Harbin,150030, China
[5] Engineering Research Center of Geothermal Resources Development Technology and Equipment, Ministry of Education, Changchun,130061, China
[6] Bureau of Geology and Mineral Resources of Heilongjiang Province, Harbin,150036, China
关键词
Abandoned wells - Geothermal heating - Geothermal wells;
D O I
10.1016/j.renene.2024.121562
中图分类号
学科分类号
摘要
Numerical simulations utilizing OpenGeoSys have been conducted on a deep coaxial borehole heat exchanger situated in the Songliao Basin. The findings reveal that the outlet temperature exhibits a downward trend as circulation flow increases, while it rises with an increase in inlet temperature. Additionally, the heat transfer power escalates with higher flow rates but diminishes as inlet temperature rises. Notably, the long-term operation results in a reduction of outlet temperature and heat transfer power. After 30 years, the decline of them is approximately 0.3 °C and 8 kW under current situation. Furthermore, long-term operation induces a decrease in formation temperature, predominantly around the vicinity of well, where the maximum temperature decline is nearly 30 °C. The reduction in formation temperature is directly proportional to the increase in flow rate and inversely proportional to inlet temperature. Within the depth range of well, the maximum influence radius expands in correlation with both the depth and duration of mining, while remaining relatively stable with variations in flow rate and inlet temperature. Following three decades of extraction, the influence radius is approximately 95m. The results provide vital scientific insights for the retrofitting of abandoned wells in Northeast China into geothermal heat exchange wells for building heating purposes. © 2024 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [11] Transient numerical model for a coaxial borehole heat exchanger with the effect of borehole heat capacity
    Yang, Xinyu
    Wang, Guodong
    Wang, Qingsheng
    Chen, Changqi
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (12) : 6551 - 6560
  • [12] Heat extraction model and characteristics of coaxial deep borehole heat exchanger
    Li, Ji
    Xu, Wei
    Li, Jianfeng
    Huang, Shuai
    Li, Zhao
    Qiao, Biao
    Yang, Chun
    Sun, Deyu
    Zhang, Guangqiu
    RENEWABLE ENERGY, 2021, 169 : 738 - 751
  • [13] Experimental investigation on heat extraction performance of deep borehole heat exchanger for ground source heat pump systems in severe cold region
    Wang, Xiaoyan
    Zhou, Chaohui
    Ni, Long
    GEOTHERMICS, 2022, 105
  • [14] Deep coaxial borehole heat exchanger: Analytical modeling and thermal analysis
    Luo, Yongqaing
    Guo, Hongshan
    Meggers, Forrest
    Zhang, Ling
    ENERGY, 2019, 185 : 1298 - 1313
  • [15] Field Test and Numerical Simulation on Heat Transfer Performance of Coaxial Borehole Heat Exchanger
    Li, Peng
    Guan, Peng
    Zheng, Jun
    Dou, Bin
    Tian, Hong
    Duan, Xinsheng
    Liu, Hejuan
    ENERGIES, 2020, 13 (20)
  • [16] Transient numerical simulation of the coaxial borehole heat exchanger with the different diameters ratio
    Iry, Soleiman
    Rafee, Roohollah
    GEOTHERMICS, 2019, 77 : 158 - 165
  • [17] Measurements and Design Calculations for a Deep Coaxial Borehole Heat Exchanger in Aachen, Germany
    Dijkshoorn, Lydia
    Speer, Simon
    Pechnig, Renate
    INTERNATIONAL JOURNAL OF GEOPHYSICS, 2013, 2013
  • [18] Field test and numerical investigation on deep coaxial borehole heat exchanger based on distributed optical fiber temperature sensor
    Huang, Yibin
    Zhang, Yanjun
    Xie, Yangyang
    Zhang, Yu
    Gao, Xuefeng
    Ma, Jingchen
    ENERGY, 2020, 210
  • [19] Numerical simulation of a Deep Borehole Heat Exchanger in the Krafla geothermal system
    Renaud, Theo
    Verdin, Patrick
    Falcone, Gioia
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 143
  • [20] Design and optimization of deep coaxial borehole heat exchangers for cold sedimentary basins
    Gascuel, Violaine
    Raymond, Jasmin
    Rivard, Christine
    Marcil, Jean-Sebastien
    Comeau, Felix-Antoine
    GEOTHERMICS, 2022, 105