Research on the performance of ultra-low temperature cascade refrigeration system based on low GWP refrigerants

被引:0
|
作者
Zhang, Chaoxu [1 ,2 ]
Xin, Gongming [1 ,2 ]
Yan, Gang [3 ]
Zhao, Hongxia [1 ,2 ]
Han, Jitian [1 ,2 ]
Li, Zengqun [4 ]
Ju, Chengcheng [4 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Peoples R China
[2] Shandong Engn Res Ctr High Efficiency Energy Stora, Jinan 250061, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
[4] Moon Environm Technol Co Ltd, Yantai 264000, Shandong, Peoples R China
关键词
Ultra-low temperature; Cascade refrigeration systems; Low GWP; Performance; Exergy; THERMODYNAMIC ANALYSIS; EXERGY ANALYSIS; MULTIOBJECTIVE OPTIMIZATION; THEORETICAL-ANALYSIS; ENERGY; R1234YF; R134A; ALTERNATIVES; REPLACEMENT; R1234ZE(E);
D O I
10.1016/j.icheatmasstransfer.2024.108232
中图分类号
O414.1 [热力学];
学科分类号
摘要
The EU Security Council and Parliament have tentatively agreed to ban fluorinated gases with a global warming potential (GWP) higher than 150 in split air conditioners and heat pumps from 2027. This will further motivate the refrigeration industry to accelerate the search for refrigerants with low GWP and zero ozone depletion potential (ODP). At present, research into low GWP refrigerants for cascade systems is limited, focusing mainly on single refrigerant substitutes without comprehensive comparisons and lax GWP restrictions. In this study, the cascade refrigeration cycle (CRS) system is established to meet the demand of -100 to -50 degrees C. The GWP of the refrigerants is strictly controlled below 150, and a comprehensive screening of the four generations of refrigerants is carried out to identify refrigerant pairs that meet environmental and refrigeration requirements. The relationship between the high-temperature cycle (HTC) evaporation temperature and the optimal coefficient of performance (COP) is determined, and the effects of the low-temperature cycle (LTC) evaporation temperature T-e concerning with mass flow rate, discharge temperature of compressor, compressor power consumption, exergy destruction, and exergy efficiency are analyzed in detail. The thermodynamically superior refrigerant pairs are identified by comparison with several conventional refrigerant pairs. The results show that when T-e > -67 degrees C, R170/R600a is preferred, and when T-e <= -67 degrees C, R170/R1270 is preferred. In the temperature range of -100 similar to -50 degrees C, R170/R1270 is the better refrigerant pair, which can improve the performance by 6.39-13.11 % than traditional refrigerant pairs. Finally, the exergy destruction analysis of CRS components is carried out, which provides a reference for refrigerant selection and system optimization of CRS in the field of ULT.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Thermodynamic analysis of two evaporator vapor compression refrigeration system with low GWP refrigerants in automobiles
    Salma Khatoon
    Munawar Nawab Karimi
    International Journal of Air-Conditioning and Refrigeration, 31
  • [42] Thermodynamic analysis of two evaporator vapor compression refrigeration system with low GWP refrigerants in automobiles
    Khatoon, Salma
    Karimi, Munawar Nawab
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2023, 31 (01)
  • [43] Performance analysis of a dual-ejector enhanced two-stage auto-cascade refrigeration cycle for ultra-low temperature refrigeration
    Shi, Rongxuan
    Bai, Tao
    Wan, Jiahao
    APPLIED THERMAL ENGINEERING, 2024, 240
  • [44] Scanning Ternary Mixtures for the Low Stage of Cascades in Ultra-Low Temperature Refrigeration
    Mota-Babiloni, Adrian
    Fernandez-Moreno, Adrian
    Gimenez-Prades, Pau
    Navarro-Esbri, Joaquin
    7TH IIR 2022 INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN 2022, 2022, : 50 - 62
  • [45] Evaluation of lower GWP alternative R-473A for R-23 in ultra-low temperature refrigeration applications
    Nayak, Gurudath
    Petersen, Michael
    Kujak, Steve
    Kolda, Michal
    Kohoutek, Tomas
    26TH IIR INTERNATIONAL CONGRESS OF REFRIGERATION, VOL 3, 2023, : 576 - 583
  • [46] RESEARCH ON HEAT TRANSFER CHARACTERISTICS OF LOW GWP REFRIGERANTS
    Kim, Yongchan x
    Kim, Dongwoo
    Lee, DongChan
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 718 - 723
  • [47] RESEARCH ON HEAT TRANSFER CHARACTERISTICS OF LOW GWP REFRIGERANTS
    Kim, Yongchan
    Kim, Dongwoo
    Lee, DongChan
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 63 - 68
  • [48] EXPERIMENTAL STUDY ON DIFFUSION ABSORPTION REFRIGERATION CYCLE USING LOW GWP REFRIGERANTS
    Jung, Han Sol
    Kim, Gahyeong
    Kang, Yong Tae
    1ST IIR INTERNATIONAL CONFERENCE ON THE APPLICATION OF HFO REFRIGERANTS, 2018, : 48 - 55
  • [49] Liquid and Vapour Injection Two-stage Cycles in Cascade Configurations for Ultra-low Temperature Refrigeration
    Mota-Babiloni, Adrian
    Udroiu, Cosmin-Mihai
    Navarro-Esbri, Joaquin
    7TH IIR 2022 INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN 2022, 2022, : 40 - 49
  • [50] Barriers to the Use of Low GWP Refrigerants in the Refrigeration and Air Conditioning Sector in Mauritius
    Dreepaul, R. K.
    Elahee, K.
    2018 5TH INTERNATIONAL SYMPOSIUM ON ENVIRONMENT-FRIENDLY ENERGIES AND APPLICATIONS (EFEA), 2018,