Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers

被引:0
|
作者
Trunov, D. N. [1 ,2 ]
Marin, V. N. [1 ,2 ]
Sadykov, R. A. [2 ]
Altynbaev, E. V. [1 ]
Glushkova, T. I. [1 ]
机构
[1] Petersburg Nucl Phys Inst, Natl Res Ctr Kurchatov Inst, Gatchina 188300, Russia
[2] Russian Acad Sci RAS, Inst Nucl Res INR, Moscow 108840, Russia
来源
JOURNAL OF SURFACE INVESTIGATION | 2024年 / 18卷 / 04期
关键词
neutrons; detectors; silicon photomultipliers; scintillator; Geiger avalanche photodiodes; multilayer detector; scintillation detector; organic light guide; wavelngth shifting fibers; light guide; DESIGN;
D O I
10.1134/S1027451024700599
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
A linear position-sensitive neutron detector based on two silicon photomultipliers and an organic light guide has been developed. Determination of the coordinate of the neutron hitting the detector comes from analyzing the amplitude of the signal received from two silicon photomultipliers located at the ends of the light guide. The results of measurements using a collimated Cf-252 source and two types of detectors based on silicon photomultipliers from Sensl with a diffusion reflector and from Hamamatsu without and with a diffusion reflector are presented. Signals from silicon photomultipliers are recorded using an analog-to-digital converter. The neutron impact coordinates are analyzed using the amplitude characteristics of the photosignal. For a detector based on silicon photomultiplier from Sensl, there is no obvious dependence of the signal amplitude on the coordinate of the neutron detection event, in contrast to detectors from Hamamatsu. The resolution of the detector coated with a diffusion reflector is about 10 mm, and without the diffusion reflector it is approximately 5 mm.
引用
收藏
页码:881 / 886
页数:6
相关论文
共 50 条
  • [41] Development of 3He-filled linear position-sensitive detector for neutron scattering instruments at CSNS
    Zhu, Lin
    Zhou, Jian-rong
    Jiang, Xin-feng
    Zhou, Xiao-juan
    Yang, Wen-qin
    Xia, Yuan-Guang
    Xiao, Liang
    Luo, Hong
    Guan, Bei-ju
    Wang, Yan-feng
    Xu, Hong
    Shen, Pei-xun
    Teng, Hai-yun
    Li, Jia-jie
    Yang, Gui-an
    Xu, Ju-ping
    Chen, Huai-can
    Wang, Song-lin
    Zhuang, Jian
    Zhang, Jun-rong
    Yin, Wen
    Sun, Zhi-jia
    Chen, Yuan-bo
    Liang, Tianjiao
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2023, 7 (01) : 100 - 106
  • [42] Development of 3He-filled linear position-sensitive detector for neutron scattering instruments at CSNS
    Lin Zhu
    Jian-rong Zhou
    Xin-feng Jiang
    Xiao-juan Zhou
    Wen-qin Yang
    Yuan-Guang Xia
    Liang Xiao
    Hong Luo
    Bei-ju Guan
    Yan-feng Wang
    Hong Xu
    Pei-xun Shen
    Hai-yun Teng
    Jia-jie Li
    Gui-an Yang
    Ju-ping Xu
    Huai-can Chen
    Song-lin Wang
    Jian Zhuang
    Jun-rong Zhang
    Wen Yin
    Zhi-jia Sun
    Yuan-bo Chen
    Tianjiao Liang
    Radiation Detection Technology and Methods, 2023, 7 : 100 - 106
  • [43] Two-dimensional neutron detector based on a position-sensitive photomultiplier
    Kurz, R.
    Reinartz, R.
    Widdau, S.
    Schelten, J.
    Scholz, A.
    Schaefer, W.
    Nuclear instruments and methods in physics research, 1988, 273 (01): : 273 - 282
  • [44] TWO-DIMENSIONAL NEUTRON DETECTOR BASED ON A POSITION-SENSITIVE PHOTOMULTIPLIER
    KURZ, R
    REINARTZ, R
    WIDDAU, S
    SCHELTEN, J
    SCHOLZ, A
    SCHAFER, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (01): : 273 - 282
  • [45] Performance test of different silicon photomultipliers for the 6LiF:ZnS(Ag) based neutron detectors of CSNS
    Huang, C.
    Tang, B.
    Yu, Q.
    Yao, Z.
    Sun, Z. J.
    Tang, M. J.
    Jiang, J. J.
    Cai, X. J.
    Yue, X. P.
    Zhou, S. H.
    Chen, S. J.
    Wang, X. K.
    Xu, H.
    Wang, Y. F.
    Liu, Y. T.
    Teng, H. Y.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (12)
  • [46] POSITION SENSITIVE NEUTRON DETECTORS USING 6Li GLASS SCINTILLATORS.
    Niimura, Nobuo
    Yamada, Kazuyoshi
    Kubota, Takeo
    Matsumoto, Akira
    Hoshino, Sadao
    Physica B: Physics of Condensed Matter & C: Atomic, Molecular and Plasma Physics, Optics, 1982, 120 (1-3): : 104 - 107
  • [47] A new position-sensitive silicon pixel detector based on bipolar transistors
    D. L. Volkov
    D. E. Karmanov
    V. N. Murashev
    S. A. Legotin
    R. A. Mukhamedshin
    A. P. Chubenko
    Instruments and Experimental Techniques, 2009, 52 : 655 - 664
  • [48] POSITION-SENSITIVE NEUTRON DETECTORS USING LI-6 GLASS SCINTILLATORS
    NIIMURA, N
    YAMADA, K
    KUBOTA, T
    MATSUMOTO, A
    HOSHINO, S
    PHYSICA B & C, 1983, 120 (1-3): : 104 - 107
  • [49] Development of a ZnS (Ag)-Silicon Photomultiplier Fast Neutron Detector for the Neutron Hodoscope at TREAT
    Wonders, Marc A.
    Chichester, David L.
    Flaska, Marek
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [50] A New Position-Sensitive Silicon Pixel Detector Based on Bipolar Transistors
    Volkov, D. L.
    Karmanov, D. E.
    Murashev, V. N.
    Legotin, S. A.
    Mukhamedshin, R. A.
    Chubenko, A. P.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2009, 52 (05) : 655 - 664