Dynamic Identification of a Lightly Damped Slender Structure Using Compressive Sensing

被引:0
|
作者
Zerbino, Matteo [1 ]
Orlando, Andrea [2 ]
Bisio, Igor [1 ]
Pagnini, Luisa C. [2 ]
机构
[1] Univ Genoa, DITEN Dept, I-16126 Genoa, Italy
[2] Univ Genoa, DICCA Dept, I-16126 Genoa, Italy
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Vectors; Compressed sensing; Damping; Vibrations; Sparse matrices; Size measurement; Monitoring; Parameter estimation; Modal analysis; Compressive sensing; modal parameters; operational modal analysis; structural monitoring; vertical slender structures; DATA LOSS RECOVERY; MODAL IDENTIFICATION; FREQUENCY; RECONSTRUCTION;
D O I
10.1109/ACCESS.2024.3411296
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A great deal of signals coming from structural monitoring scenarios are sparse in the frequency domain, suggesting the application of Compressive Sensing (CS) techniques in order to reduce the quantity of transmitted information. CS can recover data vectors starting from a subset of the original vector entries, thus allowing to recover a previously sampled signal with much less samples than those suggested by the Nyquist-Shannon theorem, and much less than what is commonly used in dynamic identification of structures. A CS technique, specifically Basis Pursuit, is applied for the dynamic identification study of a 30-meter-high lightning rod, consisting of a steel monotubular pole, where possible issues had been raised concerning fatigue damage due to resonant response with the first and second modes of vibration. An experimental measurement campaign was carried out to estimate damping coefficients useful for structural verifications. The ambient response was collected using triaxial accelerometers positioned at the top and at an intermediate height, which transmit data via WiFi to a nearby workstation. Different sampling frequencies for the compressed records are utilized for the dynamic identification of the structure, comparing modal frequencies and damping ratios with values obtained from the original records to find the best trade-off between data reduction and accuracy of modal parameters. Despite the usual challenges inherent in identification problems, further complicated by the low damping levels of the structure under consideration, the comparisons demonstrate a very good approximation. Fundamental frequencies are accurately estimated, while the slight discrepancies in the damping coefficients are associated with the intrinsic uncertainties of this parameter. Regarding the structural aspect of the case study, the outcomes of the analysis indicate very low damping values, pointing to potential criticality, particularly in the second mode of vibration. Moreover, the solid approximation achieved with the CS technique marks a significant advancement in applying IoT solutions for structural monitoring, emphasizing a significant reduction in data flow without affecting data quality. This may lead to several benefits, including simpler installation and maintenance, lower costs, and decreased energy consumption.
引用
收藏
页码:153171 / 153180
页数:10
相关论文
共 50 条
  • [41] System Identification of Lightly Damped Systems Using Recursive Kautz Functions-Case Study With Coriolis Mass Flow Meter
    Rajaprasanna, R.
    Begum, K. Ghousiya
    Balasubramanian, G.
    IEEE ACCESS, 2021, 9 : 70924 - 70934
  • [42] System Identification of Lightly Damped Systems Using Recursive Kautz Functions-Case Study with Coriolis Mass Flow Meter
    Rajaprasanna, R.
    Ghousiya Begum, K.
    Balasubramanian, G.
    IEEE Access, 2021, 9 : 70924 - 70934
  • [43] Secrecy using Compressive Sensing
    Agrawal, Shweta
    Vishwanath, Sriram
    2011 IEEE INFORMATION THEORY WORKSHOP (ITW), 2011,
  • [44] Improved FRF Measurements of Lightly Damped Systems Using Local Rational Models
    Peumans, Dries
    Busschots, Cedric
    Vandersteen, Gerd
    Pintelon, Rik
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (07) : 1749 - 1759
  • [45] APPLICATION OF IDENTIFICATION IN H-INFINITY TO LIGHTLY DAMPED SYSTEMS - 2 CASE-STUDIES
    FRIEDMAN, JH
    KHARGONEKAR, PP
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 1995, 3 (03) : 279 - 289
  • [46] Examples of Output-only Modal Identification Using Compressive Sensing Techniques
    Zebadua, Augusto
    Amblard, Pierre-Olivier
    Moisan, Eric
    Michel, Olivier
    Carmona, Mikael
    Paleologue, Alexandre
    Billeres, Malvina
    STRUCTURAL HEALTH MONITORING 2015: SYSTEM RELIABILITY FOR VERIFICATION AND IMPLEMENTATION, VOLS. 1 AND 2, 2015, : 1291 - 1298
  • [47] A unified algorithmic framework for dynamic compressive sensing
    Liu, Xiaozhi
    Xia, Yong
    SIGNAL PROCESSING, 2025, 232
  • [48] Damage Identification Scheme Based on Compressive Sensing
    Wang, Ying
    Hao, Hong
    JOURNAL OF COMPUTING IN CIVIL ENGINEERING, 2015, 29 (02)
  • [49] Efficacy of compressive sensing for dynamic spectrum access
    Odejide, Olusegun
    Annamalai, Annamalai
    Akujuobi, Cajetan
    DEFENSE TRANSFORMATION AND NET-CENTRIC SYSTEMS 2010, 2010, 7707
  • [50] Stability Analysis of a Lightly Damped Structure Harmonically Excited by a One-Sided Magnetic Exciter
    Nandi, A.
    Neogy, S.
    Sarkar, S.
    Irretier, H.
    ADVANCES IN VIBRATION ENGINEERING, 2010, 9 (03): : 259 - 271