Examination of Magnetic Shield for Capsule Endoscope Magnetic Guidance Magnet

被引:0
|
作者
Ozawa Y. [1 ]
Morikawa N. [1 ]
Tashiro K. [1 ]
Wakiwaka H. [1 ]
Mizuno T. [1 ]
Ohmiya N. [2 ]
机构
[1] Tashiro Lab., School of Engineering, Shinshu University, 4-17-1, Wakasato, Nagano
[2] Fujita Medical University, 1-98, Tarakugokubo, Kutsukake-cho, Toyoake
关键词
magnetic dipole moment; magnetic shield; magnetic shield ratio;
D O I
10.1541/ieejfms.142.383
中图分类号
学科分类号
摘要
In this report, the magnetic dipole moment was used to determine the need for a magnetic shield for capsule endoscopy guiding device. In addition, the index of the number of layers of MSC was examined from the evaluation of the magnetic shield characteristics of the open pail can, which is attracting attention as MSC, and the magnetic dipole moment. As a result, it became clear that the magnetic guiding device needs to be magnetically shielded at 11 Am2 and above. In addition, when the shielding performance of the open pail can was evaluated, it was shown by analysis that the magnetic flux density could be reduced by up to 1.53 mT and the relative permeability was 1000. Finally, it was found that when the magnetic dipole moment of the magnetic inducer is less than 41 Am2, only the open pail can is required, and when it is 41 Am2 or more, the MSC needs to have two or more layers. © 2022 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:383 / 389
页数:6
相关论文
共 50 条
  • [31] Feasibility and safety of a novel magnetic-assisted capsule endoscope system in a preliminary examination for upper gastrointestinal tract
    Lien, Gi-Shih
    Wu, Ming-Shun
    Chen, Chun-Nan
    Liu, Chih-Wen
    Suk, Fat-Moon
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2018, 32 (04): : 1937 - 1944
  • [32] Design and Prototyping of a Soft Magnetic Anchored and Guidance Endoscope System
    Cheng, Truman
    Ng, Calvin Sze Hang
    Chiu, Philip Wai Yan
    Li, Zheng
    2017 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2017, : 2902 - 2908
  • [33] A Novel Method for Locating a Magnetic-Assisted Capsule Endoscope System
    Yen, Sheng-Yang
    Huang, Hao-En
    Chen, Hsuan-Chen
    Huang, Fong-Wen
    Suk, Fat-Moon
    Lien, Gi-Shih
    Liu, Chih-Wen
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (10)
  • [34] Study on the system of a capsule endoscope driven by an outer rotational magnetic field
    Zhang, Wei
    Chen, Yingjun
    Huang, Ping
    PROCEEDINGS OF THE 2006 IEEE/ASME INTERNATIONAL CONFERENCE ON MECHATRONIC AND EMBEDDED SYSTEMS AND APPLICATIONS, 2006, : 186 - +
  • [35] Research on Coaxial Control of Magnetic Spiral-Type Capsule Endoscope
    Ye, Bo
    Zhong, Zhaoquan
    Zhang, Wei
    Hu, Donghong
    IEEE ACCESS, 2020, 8 (08): : 108113 - 108120
  • [36] Remote Magnetic Manipulation of a Wireless Capsule Endoscope in the Esophagus and Stomach of Man
    Swain, Paul
    Toor, Arifa
    Manz, Bertram
    Volke, Frank
    Gerber, Jeremy
    Rabinowitz, Elisha
    Rothstein, Richard I.
    GASTROENTEROLOGY, 2009, 136 (05) : A130 - A130
  • [37] Magnetic Maneuvering of a Capsule Endoscope in the Human Stomach Using a Handheld System
    Keller, J.
    Fibbe, C.
    Rosien, U.
    Layer, P.
    ENDOSKOPIE HEUTE, 2010, 23 (04) : 303 - 304
  • [38] Active actuation system of wireless capsule endoscope based on magnetic field
    Chen, Dongmei
    Hu, Chao
    Wang, Lei
    Meng, Max Q. -H.
    2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, VOLS 1-5, 2007, : 99 - 103
  • [39] Simulation and analysis of 2D magnetic field of capsule endoscope
    Li Hanping
    Li Guoli
    Wang Qunjing
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 5198 - 5200
  • [40] Magnetic localization and orientation of the capsule endoscope based on a random complex algorithm
    He, Xiaoqi
    Zheng, Zizhao
    Hu, Chao
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2015, 8 : 175 - 184