Performance enhancement in air gap membrane distillation using heat recovery configurations

被引:0
|
作者
Zoromba, Mohamed Shafick [1 ]
Abdel-Aziz, Mohamed Helmy [1 ]
Attar, Alaa [2 ]
Bassyouni, M. [3 ,4 ,6 ]
Elhenawy, Yasser [4 ,5 ]
机构
[1] Chemical and Materials Engineering Department, King Abdulaziz University, Rabigh,21911, Saudi Arabia
[2] Mechanical Engineering Department, King Abdulaziz University, Rabigh,21911, Saudi Arabia
[3] Department of Chemical Engineering, Faculty of Engineering, Islamic University of Madinah, Madinah,42351, Egypt
[4] Center of Excellence for Membrane Testing and Characterization (CEMTC), Port-Said University, 42526, Egypt
[5] Department of Mechanical Power Engineering, Faculty of Engineering, Port Said University, 42526, Egypt
[6] Department of Chemical Engineering, Faculty of Engineering, Port Said University, 42526, Egypt
来源
Results in Engineering | 2024年 / 24卷
关键词
D O I
10.1016/j.rineng.2024.103391
中图分类号
学科分类号
摘要
Experimental investigations were conducted on an air gap membrane distillation (AGMD) unit to evaluate the impact of heat recovery on system performance. The study utilized a steady-state heat source in conjunction with a spiral air gap membrane module for water desalination. The process was implemented using two configurations aimed to minimize heat loss enhancing productivity, gain output ratio (GOR), and thermal efficiency. The experiments involved feedwater with salt concentrations ranging from 10,000 to 30,000 ppm. The measurements were recorded for inlet and outlet temperatures of the heat source, water productivity, and thermal efficiency at various coolant and water feed flow rates. These configurations effectively addressed critical technical challenges in thermal AGMD systems by optimizing heat recovery. The incorporation of heat recovery resulted in a significant increase in water productivity by 37.07 % compared to systems without heat recovery while maintaining the same initial heat input. The heat recovery in series (HRSS) and parallel (HRPS) configurations resulted in power consumption reductions of approximately 29.7 % and 23.1 %, respectively compared to the conventional configuration (CC) at a flow rate of 12 L/min. The levelized cost of water (LCOW) for the AGMD system was comprehensively evaluated and found to be $ 7.71 per cubic meter. This figure reflected the total cost of water production over the system's operational lifespan including capital expenditures, operating and maintenance costs, and energy consumption. The calculated LCOW provides a clear indicator of the system's economic viability, demonstrating the cost required to produce each cubic meter of water through the AGMD. © 2024 The Author(s)
引用
收藏
相关论文
共 50 条
  • [41] Study on the performance of double-pipe air gap membrane distillation module
    Liu, Zhiyu
    Gao, Qijun
    Lu, Xiaolong
    Zhao, Lihua
    Wu, Song
    Ma, Zhong
    Zhang, Hao
    DESALINATION, 2016, 396 : 48 - 56
  • [42] Performance Analysis of Air Gap Membrane Distillation Process Enhanced with Air Injection for Water Desalination
    Ibarra-Bahena, Jonathan
    Dehesa-Carrasco, Ulises
    Villalobos-Hernández, Rogelio Servando
    Garrido-Hoyos, Sofía
    Rivera, Wilfrido
    Membranes, 2024, 14 (11)
  • [43] Experimental study of air gap and direct contact membrane distillation configurations: application to geothermal and seawater desalination
    El Amali, A.
    Bouguecha, S.
    Maalej, M.
    DESALINATION, 2004, 168 : 357 - 357
  • [44] An air-conditioning system performance enhancement by using heat pipe based heat recovery technology
    Ahmadzadehtalatapeh, M.
    SCIENTIA IRANICA, 2013, 20 (02) : 329 - 336
  • [45] Performance of asymmetric hollow fibre membranes in membrane distillation under various configurations and vacuum enhancement
    Zhang, Jianhua
    Li, Jun-De
    Duke, Mikel
    Xie, Zongli
    Gray, Stephen
    JOURNAL OF MEMBRANE SCIENCE, 2010, 362 (1-2) : 517 - 528
  • [46] Permeate flux enhancement with a helical wired concentric tube in air gap membrane distillation systems
    Ho, Chii-Dong
    Chen, Luke
    Wu, Kun-Yi
    Ni, Chi-Hsiang
    Chew, Thiam Leng
    DESALINATION AND WATER TREATMENT, 2020, 202 : 150 - 168
  • [47] Two-phase flow enhancement of air gap membrane distillation for aqueous NaCl solution
    Pan, Yanqiu (yqpan@dlut.edu.cn), 2017, Materials China (36):
  • [48] Distillate flux enhancement in the air gap membrane distillation with inserting carbon-fiber spacers
    Ho, Chii-Dong
    Chen, Luke
    Huang, Mei-Chih
    Lai, Jing-Yuan
    Chen, Yu-An
    SEPARATION SCIENCE AND TECHNOLOGY, 2017, 52 (18) : 2815 - 2826
  • [49] HEAT-RECOVERY CHARACTERISTICS OF MEMBRANE DISTILLATION
    KUROKAWA, H
    SAWA, T
    KAGAKU KOGAKU RONBUNSHU, 1995, 21 (02) : 286 - 293
  • [50] Treatment of saline solutions using Air Gap Membrane Distillation: Experimental study
    Alkhudhiri, Abdullah
    Darwish, Naif
    Hilal, Nidal