Measurement of laser linewidth by delayed self-heterodyne interferometry with ultra-short optical fiber

被引:0
|
作者
Tang, Yu [1 ,2 ]
Yang, Chuang [1 ,2 ]
Ren, Shuang [1 ,2 ]
Wang, Siyuan [1 ,2 ]
Zhou, Hanbin [1 ,2 ]
机构
[1] Xidian Univ, Natl Key Lab Radar Signal Proc, Xian, Peoples R China
[2] Xidian Univ, Inst Informat Sensing, Xian, Peoples R China
关键词
self-heterodyne; laser linewidth; ultra-short optical fiber; coherent envelope;
D O I
10.1117/1.OE.63.10.106104
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We propose a method for the measurement of laser linewidth by delayed self-heterodyne interferometry with ultra-short optical fiber. This method can measure the laser linewidth by the signal-to-noise ratio characteristics of the self-heterodyne power spectrum and the frequency spacing of the coherent envelope peaks. It can measure the laser linewidth at the kHz level using several meters of fiber. The feasibility and accuracy of this method are proved by theoretical derivation and experimental verification. In contrast to the conventional linewidth measurement method, the proposed method is simpler to implement, does not necessitate a rigorous experimental environment, and has a broad application range, which can be used as a new scheme for measuring laser linewidth.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Accurate evaluation of self-heterodyne laser linewidth measurements using Wiener filters
    Kantner, Markus
    Mertenskoetter, Lutz
    OPTICS EXPRESS, 2023, 31 (10) : 15994 - 16009
  • [42] Broadband phase noise measurement of single-frequency lasers by the short-fiber recirculating delayed self-heterodyne method
    Chen, Xu
    Liu, Jingmin
    Jiang, Junjie
    Yang, Shichao
    Yu, Xia
    OPTICS LETTERS, 2024, 49 (03) : 622 - 625
  • [43] Measurement of transient wavelength and line-width of DFB diode laser by delayed self-heterodyne interferometer
    Liu, Jingwang
    Du, Zhenhui
    An, Ying
    Li, Jinyi
    Gao, Dongyu
    Yu, Kexin
    6TH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2010, 7544
  • [44] Ultra-short distributed feedback fiber laser with sub-kilohertz linewidth for sensing applications
    Wong, A. C. L.
    Chung, W. H.
    Tam, H. Y.
    Lu, C.
    LASER PHYSICS, 2011, 21 (01) : 163 - 168
  • [45] Dynamic frequency-noise spectrum measurement for a frequency-swept DFB laser with short-delayed self-heterodyne method
    Zhou, Qian
    Qin, Jie
    Xie, Weilin
    Liu, Zhangweiyi
    Tong, Yitian
    Dong, Yi
    Hu, Weisheng
    OPTICS EXPRESS, 2015, 23 (22): : 29245 - 29257
  • [46] Laser frequency stability estimation and velocity measurement in the atmosphere with self-heterodyne
    Zhang, Heyong
    Wang, Hualong
    Zhao, Shuai
    OPTICA APPLICATA, 2016, 46 (02) : 305 - 316
  • [47] Determination of white and 1/f FM noise components of semiconductor laser spectrum by a delayed self-heterodyne interferometer using short delay fiber
    Islam, MN
    Nomura, T
    Imai, M
    Huda, MQ
    DESIGN, FABRICATION AND CHARACTERIZATION OF PHOTONIC DEVICES, 1999, 3896 : 328 - 332
  • [48] Contrast Measurement of Ultra-short Laser Pulses
    Zhang, Fuling
    Ouyang, Xiaoping
    Xie, Xinglong
    Yang, Qingwei
    Guo, Ailin
    Bi, Qunyu
    Sun, Meizhi
    Lin, Zunqi
    2009 LASERS & ELECTRO-OPTICS & THE PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1 AND 2, 2009, : 479 - 480
  • [49] Limitation and improvement in the performance of recirculating delayed self-heterodyne method for high-resolution laser lineshape measurement
    Tsuchida, Hidemi
    OPTICS EXPRESS, 2012, 20 (11): : 11679 - 11687
  • [50] Laser frequency noise measurement using an envelope-ratio method based on a delayed self-heterodyne interferometer
    Li, Yimin
    Fu, Zhuo
    Zhu, Lei
    Fang, Jie
    Zhu, Haoran
    Zhong, Jiaqi
    Xu, Peng
    Chen, Xi
    Wang, Jin
    Zhan, Mingsheng
    OPTICS COMMUNICATIONS, 2019, 435 : 244 - 250