Non-contact mechanical Q-factor measurement system based on electromagnetic acoustic transducer

被引:0
|
作者
Tsuchida, Masatoshi [1 ]
Morita, Takeshi [1 ]
机构
[1] Univ Tokyo, Dept Precis Engn, 7-3-1 Hongo,Bunkyo Ku, Tokyo 1138656, Japan
来源
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY | 2024年 / 91卷
关键词
Q-factor; Measurement; EMAT; Ultrasound levitation; INTERNAL-FRICTION; ELASTIC-CONSTANTS; ULTRASONIC VIBRATION; STAINLESS-STEEL; STRESS; WAVES;
D O I
10.1016/j.precisioneng.2024.09.019
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The mechanical quality factor (Q-factor), which is the reciprocal of the vibration loss constant, is one of the most important parameters in vibration engineering; however, there are no methods for its precise measurement. Q-factor databases are thus commonly used. This study proposes a completely non-contact measurement system for the Q-factor that combines non-contact excitation (achieved using an electromagnetic acoustic transducer) with non-contact support (achieved using near-field ultrasonic levitation based on two Langevin transducers). The proposed method was used to measure the Q-factor for a stainless steel (SUS304) sample (thin cylindrical rod with a diameter of 1.5 mm and a length of 80 mm)and a duralumin (A2017). The 5 times average Q-factor was 2010 with standard deviation of 50 for stainless steel (SUS304), and 49,000 with standard deviation of 3900 for duralumin (A2017). The proposed method also allowed for the measurement of Young's modulus, resulting in 217.17 +/- 0.34 GPa for stainless steel (SUS304), and 71.39 +/- 0.20 GPa for duralumin (A2017).
引用
收藏
页码:390 / 395
页数:6
相关论文
共 50 条
  • [21] Non-contact torsion transducer based on the measurement of Moire patterns using plastic optical fibers
    Lomer, Mauro
    Contreras, Kevin
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION V, PTS 1 AND 2, 2007, 6616
  • [22] An Electromagnetic System for the Non-Contact Excitation of Bladed Disks
    C. M. Firrone
    T. Berruti
    Experimental Mechanics, 2012, 52 : 447 - 459
  • [23] An Electromagnetic System for the Non-Contact Excitation of Bladed Disks
    Firrone, C. M.
    Berruti, T.
    EXPERIMENTAL MECHANICS, 2012, 52 (05) : 447 - 459
  • [24] Non-contact measurement of acoustic emission in materials by laser interferometry
    Enoki, M.
    Watanabe, M.
    Chivavibul, P.
    Kishi, T.
    SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2000, 1 (03) : 157 - 165
  • [25] Inspection of drinks cans using non-contact electromagnetic acoustic transducers
    Ho, K. S.
    Billson, D. R.
    Hutchins, D. A.
    JOURNAL OF FOOD ENGINEERING, 2007, 80 (02) : 431 - 444
  • [26] A DIGITAL SYSTEM FOR MEASUREMENT OF RESONANT-FREQUENCY AND Q-FACTOR
    PANDRANGI, RK
    STUCHLY, SS
    BARSKI, M
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1982, 31 (01) : 18 - 21
  • [27] Uncertainty analysis of Q-factor measurement in cavity resonator method by electromagnetic simulation
    Park, Jae-Hwan
    Park, Jae-Gwan
    SN APPLIED SCIENCES, 2020, 2 (05):
  • [28] Uncertainty analysis of Q-factor measurement in cavity resonator method by electromagnetic simulation
    Jae-Hwan Park
    Jae-Gwan Park
    SN Applied Sciences, 2020, 2
  • [29] Energy Efficiency Measurement of Mechanical Crushing Based on Non-Contact Identification Method
    Lu, Xiaoquan
    Duan, Meimei
    Su, Huiling
    Li, Bo
    Liu, Ying
    SYMMETRY-BASEL, 2024, 16 (07):
  • [30] Simple measurement system for non-contact oxygen saturation measurement
    Hino Y.
    Kariya K.
    Maruyama K.
    Tamura H.
    Akimoto T.
    Transactions of Japanese Society for Medical and Biological Engineering, 2019, 57 (06): : 230 - 235