Non-contact mechanical Q-factor measurement system based on electromagnetic acoustic transducer

被引:0
|
作者
Tsuchida, Masatoshi [1 ]
Morita, Takeshi [1 ]
机构
[1] Univ Tokyo, Dept Precis Engn, 7-3-1 Hongo,Bunkyo Ku, Tokyo 1138656, Japan
关键词
Q-factor; Measurement; EMAT; Ultrasound levitation; INTERNAL-FRICTION; ELASTIC-CONSTANTS; ULTRASONIC VIBRATION; STAINLESS-STEEL; STRESS; WAVES;
D O I
10.1016/j.precisioneng.2024.09.019
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The mechanical quality factor (Q-factor), which is the reciprocal of the vibration loss constant, is one of the most important parameters in vibration engineering; however, there are no methods for its precise measurement. Q-factor databases are thus commonly used. This study proposes a completely non-contact measurement system for the Q-factor that combines non-contact excitation (achieved using an electromagnetic acoustic transducer) with non-contact support (achieved using near-field ultrasonic levitation based on two Langevin transducers). The proposed method was used to measure the Q-factor for a stainless steel (SUS304) sample (thin cylindrical rod with a diameter of 1.5 mm and a length of 80 mm)and a duralumin (A2017). The 5 times average Q-factor was 2010 with standard deviation of 50 for stainless steel (SUS304), and 49,000 with standard deviation of 3900 for duralumin (A2017). The proposed method also allowed for the measurement of Young's modulus, resulting in 217.17 +/- 0.34 GPa for stainless steel (SUS304), and 71.39 +/- 0.20 GPa for duralumin (A2017).
引用
收藏
页码:390 / 395
页数:6
相关论文
共 50 条
  • [1] Development of a non-contact stress measurement system during tensile testing using the electromagnetic acoustic transducer for a Lamb wave
    Murayam, R
    Misumi, K
    NDT & E INTERNATIONAL, 2006, 39 (04) : 299 - 303
  • [2] Fabrication of Si-based AFM Probe with High Q-factor for Fast Non-Contact Mode Scanning
    Bahn, Sebin
    Choi, Soo Bong
    Park, Woongkyu
    Jeong, Hae-Yong
    Park, Kyung-Ho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 74 (02) : 94 - 97
  • [3] Fabrication of Si-based AFM Probe with High Q-factor for Fast Non-Contact Mode Scanning
    Sebin Bahn
    Soo Bong Choi
    Woongkyu Park
    Hae-Yong Jeong
    Kyung-Ho Park
    Journal of the Korean Physical Society, 2019, 74 : 94 - 97
  • [4] Non-contact liquid level measurement with electromagnetic-acoustic resonator sensors
    Lucklum, F.
    Jakoby, B.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (12)
  • [5] A Study on the Shape Evaluation using Non-contact Electromagnetic Measurement System
    Kim, Jae Min
    Yun, Seung Ho
    Won, Hyuk
    Park, Gwan Soo
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2010, 20 (02): : 45 - 51
  • [6] Acoustic containerless experiment system: a non-contact surface tension measurement
    Elleman, D.D.
    Wang, T.G.
    Barmatz, M.
    NASA Technical Memorandum, 1988, 2 (4069): : 557 - 567
  • [7] NEW SYSTEM FOR MICROWAVE Q-FACTOR MEASUREMENT
    CULLEN, AL
    DAVIES, JA
    IEE JOURNAL ON MICROWAVES OPTICS AND ACOUSTICS, 1978, 2 (03): : 77 - 84
  • [8] Non-contact and contact measurement system for detecting projectile position in electromagnetic launch bore
    Xu, Weidong
    Yuan, Weiqun
    Xu, Rong
    Zhao, Hui
    Cheng, Wenping
    Zhang, Dongdong
    Zhao, Ying
    Yan, Ping
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (12)
  • [9] Neural network based non-contact measurement system
    Zhou, LM
    Waheed, A
    Lu, BH
    AUTOMATED OPTICAL INSPECTION FOR INDUSTRY, 1996, 2899 : 500 - 507
  • [10] Development of a laser non-contact shadow mask Q factor measurement machine
    Lin, Lizong
    Ke, Zili
    Wang, Gang
    Min, Lijun
    Wang, Jun
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2006, 27 (08): : 885 - 888