Secondary cooling concepts to increase the efficiency and flexibility of slab casters

被引:0
|
作者
机构
[1] Weyer, Axel
[2] Frick, Jürgen
来源
Weyer, A. (Axel.Weyer@sms-siemag.com) | 2013年 / Verlag Stahleisen GmbH卷 / 36期
关键词
Control range - Cooling model - Cooling strategy - Cooling water flow rates - Energy inputs - Flexible adjustment - German companies - Secondary cooling;
D O I
暂无
中图分类号
学科分类号
摘要
German companies Lechier and SMS Siemag have discovered a spray nozzle technology called X-Cast® EcoCooler for an extended control range and a reduction of energy input. The starting point of a new development is the required technology and its boundary conditions. mum casting width. In order to ensure an optimum setting of secondary cooling, supply of water over the slab width, and to allow for a flexible adjustment to the various sections widths, control loops 3 to 11 are designed as separate control loops. This way, a differentiated control or selective disconnection of the control loops is possible for an optimized cooling strategy where various types of steel grades are involved. To optimally design the solidification of the hot strand, cooling models are used in process automation to calculate the required cooling water flow rates and to thus preset the setpoints for the necessary spray water volume in a differentiated manner.
引用
收藏
相关论文
共 50 条
  • [41] Experimental Increase in the Efficiency of a Cooling Circuit Using a Desuperheater
    Formanek, Marian
    Horak, Petr
    Diblik, Josef
    Hirs, Jiri
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2016, 60 (03): : 355 - 360
  • [42] Efficiency increase of an induction motor by improving cooling performance
    Yoon, MK
    Jeon, CS
    Kauh, SK
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (01) : 1 - 6
  • [43] Cooling efficiency of vests with different cooling concepts over 8-hour trials
    Ciuha, Ursa
    Valencic, Tamara
    Mekjavic, Igor B.
    ERGONOMICS, 2021, 64 (05) : 625 - 639
  • [44] Method of Determining an Efficient Rate for the Secondary Cooling of a Continuous-Cast Slab
    Biryukov, A. B.
    Ivanova, A. A.
    METALLURGIST, 2015, 58 (11-12) : 967 - 972
  • [45] Numerical Simulation of Linear Electromagnetic Stirring in Secondary Cooling Region of Slab Caster
    HUANG Jun-tao
    WANG En-gang
    HE Ji-cheng
    JournalofIronandSteelResearch(International), 2003, 10 (03) : 16 - 21
  • [46] OPTIMIZATION ON THE SECONDARY COOLING PATTERNS FOR WIDE AND THICK CONTINUOUS CASTING SLAB CORNER
    Ma, Huan
    Wang, Qian
    Li, Yu-gang
    Lu, Yong-jian
    He, Shengping
    METALURGIA INTERNATIONAL, 2012, 17 (06): : 30 - 34
  • [47] Dynamic control model of secondary cooling zone with crater control for slab caster
    Yanshan Univ, Yanshan, China
    Kang T'ieh/Iron and Steel (Peking), 1997, 32 (06): : 29 - 32
  • [48] THERMAL CONDUCTION BY GUIDE ROLLERS IN THE SECONDARY COOLING ZONE OF SLAB CASTING PLANTS
    WUNNENBERG, K
    ARCHIV FUR DAS EISENHUTTENWESEN, 1982, 53 (01): : 19 - 20
  • [49] Rebuilding the secondary cooling system on the continuous slab caster at the Kamastal' Metallurgical Plant
    Kuklev, A. V.
    Tinyakov, V. V.
    Aizin, Yu. M.
    Sgibnev, G. V.
    Izhik, A. K.
    Sakhnov, B. I.
    Potekhin, A. G.
    Stroganov, B. F.
    METALLURGIST, 2007, 51 (11-12) : 612 - 616
  • [50] Influence of secondary cooling water distribution on temperature field of continuously cast slab
    Chen, Suqiong
    Cui, Lixin
    Zhang, Jiaquan
    Gan, Yong
    Ni, Mansen
    Kang T'ieh/Iron and Steel (Peking), 2002, 37 (11): : 18 - 19