Optimization of the Electron Spectrometer Telescope geometry for the PRESET satellite through Monte Carlo simulation

被引:0
|
作者
Dyer, Benjamin [1 ]
Cheng, Xingzhi [1 ]
Hanu, Andrei R. [1 ,2 ]
Byun, Soo Hyun [1 ]
机构
[1] McMaster Univ, Dept Phys & Astron, Hamilton, ON L8S 4K1, Canada
[2] Bruce Power, Tiverton, ON N0G 2T0, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Electron telescope; Collimator; Silicon detector; Response matrix; GEANT4; RADIATION; FIELD;
D O I
10.1016/j.nima.2024.169954
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Electron Spectrometer Telescope (EST) aboard the PRESET satellite mission aims to measure the pitch angle distribution of 0.3-4 MeV electrons in the outer Van Allen belts. The PRESET satellite is planned to launch into a sun-synchronous low Earth orbit in Q2, 2026. We present comprehensive Monte Carlo simulations to optimize the design and response of the EST instrument. The EST consists of a stack of silicon strip detectors and a collimator to take pitch-angle dependent electron spectral measurements with a target angular resolution of 6 degrees degrees while rejecting the proton, heavy ion and gamma detection events. Various collimator designs and detector stacking configurations are investigated using the Geant4 code to deduce an optimal design and configuration. For validation of the Geant4 simulations, a benchmark test spectrometer was set up using a stack of four silicon detectors and a good agreement between the measured and simulated responses was found for a beta spectrum from a 90 Sr/ 90 Y source. The collimator design was optimized by adjusting total length, aperture size, number of view-ports and collimator materials. The optimum aperture size and the number of view- ports were determined by varying them and selecting the best cases that meet the angular resolution and the geometric factor requirements. Moreover, to address the under-utilization of the front position-sensitive detector encountered in a typical pin-hole collimator, two offset collimators with tilted axes were employed. Extensive simulations were carried out by varying the number of silicon detectors and the thickness of each detector to optimize the configuration of the silicon detector stack. An optimum thickness of the front detector was found to be 140 mu m, which can minimize the perturbation counts caused by the proton detection events. For the other detectors, a stack of four 1.5 mm thick detectors was chosen to achieve a good sensitivity to low energy electrons at a tolerable complexity of the system. The angular response simulated for the optimum design of the EST showed a resolution of 5.5 degrees, degrees , which is slightly better than the target resolution of 6 degrees. degrees . The response matrices of the final design simulated for isotropic electron and proton fields showed a high geometric factor, which is expected to produce an average electron counting rate of 230 cps within the trapped region with a negligible contamination of the electron spectrum by protons except for a mild contamination by the 1.0-1.1 MeV protons.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Monte Carlo simulation for the MAGIC telescope
    Majumdar, P.
    Moralejo, A.
    Bigongiari, C.
    Blanch, O.
    Sobczynska, D.
    Proceedings of the 29th International Cosmic Ray Conference, Vol 5: OG 2.5, 2.6 & 2.7, 2005, : 203 - 206
  • [2] Network flow Optimization through Monte Carlo Simulation
    Hande, Sayaji
    Patidar, Prasoon
    Meena, Sachin
    Banerjee, Saurabh
    2018 FIFTH INTERNATIONAL CONFERENCE ON PARALLEL, DISTRIBUTED AND GRID COMPUTING (IEEE PDGC), 2018, : 95 - 101
  • [3] Optimization of Monte Carlo Code for Clinical Simulation of Electron Beams
    Guerra Gutierrez, P.
    Udias, J. M.
    Herranz, E.
    Valdivieso, M.
    Calama, J.
    Illana, C.
    Ledesma-Carbayo, M. J.
    Santos, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S870 - S871
  • [4] Optimization of positron lifetime spectrometer using Monte-Carlo simulation of the detectors
    Crivelli, P.
    Gendotti, U.
    Rubbia, A.
    Liszkay, L.
    Perez, P.
    POSITRON AND POSITRONIUM CHEMISTRY, 2009, 607 : 251 - +
  • [5] MONTE-CARLO SIMULATION OF ELECTRON PHOTON CERENKOV CASCADES IN GENERALIZED GEOMETRY
    MACK, JM
    JORDAN, TM
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1984, 46 : 434 - 435
  • [6] Monte Carlo simulation of electron transmission through masks in projection electron lithography
    Xiao Pei
    Zhang Zeng-Ming
    Sun Xia
    Ding Ze-Jun
    ACTA PHYSICA SINICA, 2006, 55 (11) : 5803 - 5809
  • [7] Monte Carlo study of a precision magnetic spectrometer with planar geometry
    Khrutchinsky, A.A.
    Lachin, Yu.Yu.
    Selivanov, V.I.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 396 (1-2): : 135 - 146
  • [8] Monte carlo simulation and optimization of three-axis neutron spectrometer for the PIK reactor
    R. G. Burkovskiĭ
    S. B. Vakhrushev
    O. I. Zvorykina
    A. A. Naberezhnov
    N. M. Okuneva
    A. V. Filimonov
    Crystallography Reports, 2007, 52 : 552 - 557
  • [9] Monte Carlo simulation and optimization of three-axis neutron spectrometer for the PIK reactor
    Burkovskii, R. G.
    Vakhrushev, S. B.
    Zvorykina, O. I.
    Naberezhnov, A. A.
    Okuneva, N. M.
    Filimonov, A. V.
    CRYSTALLOGRAPHY REPORTS, 2007, 52 (03) : 552 - 557
  • [10] MONTE-CARLO SIMULATION FOR COMPTON SUPPRESSION SPECTROMETER
    TSOU, RH
    LIN, SC
    KIANG, LL
    COMPUTER PHYSICS COMMUNICATIONS, 1994, 83 (01) : 30 - 44