Comparison of tendon attachment to 3D printed Ti6Al4V implant versus Trevira® implant: A paired experimental animal study

被引:0
|
作者
Freund, Sarah S. [1 ]
Borgognoni, Anna B. [1 ]
Bendtsen, Michael M. [1 ]
Baas, Jorgen [1 ]
Byskov, Jeppe S. [2 ]
Ranjkesh, Bahram [3 ]
Baerentzen, Steen [5 ]
Nyengaard, Jens R. [4 ,5 ]
Baad-Hansen, Thomas [1 ]
机构
[1] Aarhus Univ Hosp, Dept Orthopaed Oncol, Palle Juul Jensens Blvd 165, DK-8200 Aarhus N, Denmark
[2] Danish Tecnol Inst, Addit Mfg, Kongsvang 29, DK-8000 Aarhus C, Denmark
[3] Aarhus Univ, Dept Dent & Oral Hlth, Sect Prosthet Dent, Vennelyst Blvd 9, DK-8000 Aarhus C, Denmark
[4] Aarhus Univ, Core Ctr Mol Morphol, Dept Clin Med, Sect Stereol & Microscopy, Aarhus, Denmark
[5] Aarhus Univ Hosp, Dept Pathol, Palle Juul Jensens Blvd 99, DK-8200 Aarhus N, Denmark
关键词
Megaprosthesis surgery; Soft-tissue reattachment; Biomechanical properties; Trevira (R) tube; Histomorphometric analysis; PATELLAR TENDON; TUMOR; RECONSTRUCTION; RESECTION; GAIT; CUPS;
D O I
10.1016/j.jmbbm.2024.106789
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Soft-tissue attachment is crucial for the success of megaprosthesis surgery and improvement in current treatment is needed. The aim of this study was to compare the biomechanical and histomorphometric properties of soft-tissue attachment between 3D printed Ti6Al4V implants featuring a 630 mu m microporous structure and commercially available Trevira (R) implants with a 200 mu m porous structure in a non-loadbearing ovine model. Methods: Ten skeletally mature ewes underwent surgical implantation with both implants. After 4-weeks, mechanical pull-out testing assessed the attachment strength, while histomorphometric analysis evaluated fibroblast cell profile density, multinucleated giant cell profile density, microvessel length and volume density. Results: 3D printed Ti6Al4V implants demonstrated a 129% greater attachment strength compared to Trevira (R) implants (p = 0.003). In the Trevira (R) group, a 35% increase in fibroblast profile density (p < 0.001) and a 98% increase in multinucleated giant cell profile density (p < 0.001) were observed, with no significant difference in microvessel length density between the groups. However, the Ti6Al4V group exhibited a 50% higher microvessel volume density (p < 0.001) compared to the Trevira (R) group. Conclusion: 3D printed Ti6Al4V implants with a 630 mu m microporous structure demonstrated superior attachment strength, enhanced neovascularization, and reduced foreign body reaction compared to the Trevira (R) implants. These findings suggest that 3D printed Ti6Al4V implants may enhance soft-tissue attachment in megaprosthesis surgeries.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] 3D laser-printed porous Ti6Al4V dental implants for compromised bone support
    Tu, Che Chang
    Tsai, Pei-, I
    Chen, San-Yuan
    Kuo, Mark Yen-Ping
    Sun, Jui-Sheng
    Chang, Jenny Zwei-Chieng
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2020, 119 (01) : 420 - 429
  • [42] 3D Finite Element Modeling of the Machining of Ti6Al4V Alloys
    Yang, Jihong
    Sun, Shoujin
    Brandt, Milan
    Yan, Wenyi
    MANUFACTURING PROCESS TECHNOLOGY, PTS 1-5, 2011, 189-193 : 1926 - +
  • [43] Research on the Dynamic Compressive Deformation Behavior of 3D-Printed Ti6Al4V
    Pu, Bo
    Li, Wenbin
    Zhang, Qing
    Zheng, Yu
    Wang, Xiaoming
    METALS, 2021, 11 (08)
  • [44] Promotion of tendon growth into implant through pore-size design of a Ti-6Al-4 V porous scaffold prepared by 3D printing
    Zheng, Yuhao
    Han, Qing
    Li, Dongdong
    Sheng, Fan
    Song, Zhiming
    Wang, Jincheng
    MATERIALS & DESIGN, 2021, 197
  • [45] Comparison Analysis of Titanium Alloy Ti6Al4V Produced by Metallurgical and 3D Printing Method
    Karolewska, Karolina
    Ligaj, Bogdan
    SCIENTIFIC SESSION ON APPLIED MECHANICS X, 2019, 2077
  • [46] 3D-printed porous Ti6Al4V scaffolds for long bone repair in animal models: a systematic review
    Yifei Gu
    Yi Sun
    Sohaib Shujaat
    Annabel Braem
    Constantinus Politis
    Reinhilde Jacobs
    Journal of Orthopaedic Surgery and Research, 17
  • [47] 3D-printed porous Ti6Al4V scaffolds for long bone repair in animal models: a systematic review
    Gu, Yifei
    Sun, Yi
    Shujaat, Sohaib
    Braem, Annabel
    Politis, Constantinus
    Jacobs, Reinhilde
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [48] Experimental Study on Surface Integrity of Ti6Al4V by Broaching
    Khanjanzadeh, P.
    Amirabadi, H.
    Sadri, J.
    International Journal of Engineering, Transactions A: Basics, 2022, 35 (02): : 481 - 492
  • [49] Experimental Study on Surface Integrity of Ti6Al4V by Broaching
    Khanjanzadeh P.
    Amirabadi H.
    Sadri J.
    International Journal of Engineering, Transactions B: Applications, 2022, 35 (02): : 481 - 492
  • [50] Mechanical Behavior of PEEK and PMMA Graphene and Ti6Al4V Implant-Supported Frameworks: In Silico Study
    Herrero-Climent, Mariano
    Sanchez-Lasheras, Fernando
    Martinez-Lopez, Jordi
    Gil, Javier
    Brizuela-Velasco, Aritza
    MATERIALS, 2025, 18 (02)