Full-scale burning tests on heat release rate of gasoline fire with water mist

被引:0
|
作者
Chow, W.K. [1 ]
Gao, Y. [2 ]
Dong, H. [2 ]
Zou, G. [2 ]
Meng, L. [2 ]
机构
[1] Arch. Science and Fire Engineering, Department of Building Services Eng., Hong Kong Polytechnic University, Hong Kong, Hong Kong
[2] Harbin Engineering University, Harbin, China
来源
Journal of Applied Fire Science | 2002年 / 11卷 / 01期
关键词
Calorimetry - Combustion - Equipment testing - Gasoline - Pyrolysis - Sprinkler systems (fire fighting);
D O I
10.2190/UNVL-0MPP-BBB8-54YJ
中图分类号
学科分类号
摘要
There are concerns on whether a water mist fire suppression system (WMFSS) can extinguish a fire quickly, though the system might be applied for suppressing or controlling the fire. It was also suggested in the literature that water mists might not always be capable of controlling a fire, even when working under the design conditions as there are many factors to be considered in designing WMFSS. This article will report on experiments on action of water mist discharged from low-pressure fire suppression system on gasoline fire. The objective is to observe more clearly the fire extinguishing mechanism. Full-scale tests were carried out at the new burning facility, PolyU/HEU Assembly Calorimeter at Lanxi, Harbin, Heilongjiang, China. There, heat release rates up to 5 MW can be measured by oxygen consumption calorimetry. Results on the heat release rate of liquid pool fires with and without discharging water mist; and the associated temperature profiles will be reported in this article. It was observed that if the flame shape did not change under the action of water mist, the burning process can be sustained although the heat release rate and temperature were both reduced. The downward push induced by discharging water mist is proposed to be one of the extinguishing mechanisms on liquid pool fires. © 2003, Baywood Publishing Co., Inc.
引用
下载
收藏
页码:21 / 40
相关论文
共 50 条
  • [31] Full-scale experimental study on water mist fire suppression in a railway tunnel rescue station: Temperature distribution characteristics
    Fan, Chuangang
    Bu, Rongwei
    Xie, Xiaoqing
    Zhou, Yang
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 146 : 396 - 411
  • [32] Full-scale burning tests on studying smoke temperature and velocity along a corridor
    Hu, LH
    Huo, R
    Lia, LZ
    Wang, HB
    Chow, WK
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2005, 20 (03) : 223 - 229
  • [33] Full-scale tests for housing
    Söderlind, L
    1ST INTERNATIONAL RILEM SYMPOSIUM ON SELF COMPACTING CONCRETE, 1999, 7 : 723 - 728
  • [34] FULL-SCALE COLLISION TESTS
    CARLEBUR, AFC
    SAFETY SCIENCE, 1995, 19 (2-3) : 171 - 178
  • [35] Full-scale experimental studies on extinguishing cooking oil fires with water mist
    State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230027, China
    Ranshao Kexue Yu Jishu, 2006, 4 (318-322):
  • [36] CORRELATION BETWEEN SMALL-SCALE RATE OF HEAT RELEASE AND FULL-SCALE ROOM FLASHOVER FOR SURFACE LININGS
    OSTMAN, BAL
    NUSSBAUM, RM
    FIRE SAFETY SCIENCE - PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM, 1989, : 823 - 832
  • [37] Heat release rate and computer fire modelling vs real-scale fire tests in passenger trains
    Capote, Jorge A.
    Alvear, Daniel
    Lazaro, Mariano
    Espina, Pablo
    FIRE AND MATERIALS, 2008, 32 (04) : 213 - 229
  • [38] Full-Scale Experiments of Fire Control and Suppression in Enclosed Car Parks: A Comparison Between Sprinkler and Water-Mist Systems
    Santangelo, Paolo E.
    Tartarini, Paolo
    Tarozzi, Luca
    FIRE TECHNOLOGY, 2016, 52 (05) : 1369 - 1407
  • [39] FULL-SCALE FIRE TEST PROGRAM
    ALPERT, RL
    FIRELINE, 1978, 5 (01): : 7 - 7
  • [40] Full-scale experimental study on fire suppression performance of a designed water mist system for rescue station of long railway tunnel
    Meng, Na
    Hu, Longhua
    Liu, Shuai
    Wu, Long
    Chen, Longfei
    Liu, Binghai
    JOURNAL OF FIRE SCIENCES, 2012, 30 (02) : 138 - 157