Characteristic of lightning shielding failure for 500 kV AC transmission lines with quadruple-circuits on one tower

被引:0
|
作者
Su, Hong-Mei
Liu, Xiao-Dong
Wei, Guo-Ping
Chai, Ya-Jing
Li, Xue
Zhou, Wen-Jun
机构
[1] Hebei Electric Power Research Institute, Shijiazhuang 050021, China
[2] School of Electrical Engineering, Wuhan University, Wuhan 430072, China
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
16
引用
收藏
页码:205 / 208
相关论文
共 50 条
  • [41] Lightning Performance Assessment of 500kV Transmission Lines in Southern China
    Zhao, Xiangen
    Xie, Yaoheng
    He, Hengxin
    He, Junjia
    Chen, Xipeng
    Cai, Hansheng
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [42] Research on the lightning shielding performance of strained angled tower for the ±1100 kV UHVDC transmission project
    Shi, Wei
    Yao, Jinxia
    Ren, Jingguo
    Li, Jie
    Zhang, Pipei
    ENERGY REPORTS, 2022, 8 : 1 - 7
  • [43] Experimental Study on Lighting Shielding Performance of ±500 kV HVDC Transmission Lines
    He, Hengxin
    He, Junjia
    Zhang, Dandan
    Ding, Li
    Jiang, Zhenglong
    Wang, Cheng
    Ye, Huisheng
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3421 - +
  • [44] Model test on the effect of hillside on lightning shielding performance of ±1100 kV transmission lines
    Wang, Yu
    Huang, Shunyong
    Deng, Yeqiang
    Chen, Xiaoyue
    Xiang, Meichen
    Wen, Xishan
    Lan, Lei
    Zhang, Tao
    Liu, Baoquan
    Jiang, Hui
    Bi, Xiaolei
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 129 (129)
  • [45] Assessment of Shielding Performance of 69/138 kV Transmission lines Exposed to Lightning Strikes
    Malcolm, Newman
    Aggarwal, Raj K.
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [46] Study on pollution flashover characteristic of insulators on 500kV AC transmission lines in high-altitude area
    Huang, Ruiping
    Zhou, Jun
    Xu, Yueneng
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 3306 - 3309
  • [47] Lightning Attachment Models and Maximum Shielding Failure Current: Application to Transmission Lines
    Mikropoulos, Pantelis N.
    Tsovilis, Thomas E.
    2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 1867 - 1874
  • [48] Influence of Lightning Current Parameters and Earthing System Designs on Tower Footing Impedance of 500 kV Lines
    Nasir, Nur Alia Farina Mohamad
    Ab Kadir, Mohd Zainal Abidin
    Osman, Miszaina
    Abd Rahman, Muhamad Safwan
    Amirulddin, Ungku Anisa Ungku
    Nasir, Mohd Solehin Mohd
    Zaini, Nur Hazirah
    Ali, Nik Hakimi Nik
    ENERGIES, 2021, 14 (16)
  • [49] Shielding failure analysis of a hybrid transmission line with AC and DC systems on the same tower
    Malicki, Pawel
    Papenheim, Simon
    Kizilcay, Mustafa
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 159 : 2 - 8
  • [50] Sensitivity of lightning shielding failure of double-circuit transmission line on tower geometric structures
    Li, Zhen
    Yu, Zhanqing
    Wang, Xi
    Peng, Xiangyang
    Li, Zhifeng
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 94 : 86 - 91