Regularities of liquid-scintillation (LS) α spectrometry

被引:0
|
作者
Egorov, V.N. [1 ]
Kolomejtsev, G.Yu. [1 ]
Poluektov, P.P. [1 ]
Chirin, N.A. [1 ]
机构
[1] FGUP VNIINM, Moscow, Russia
来源
| 2002年 / Atomnaya Energiya卷 / 93期
关键词
Actinides - Alpha particles - Calibration - Liquids - Phosphors - Radioisotopes - Spectrum analysis;
D O I
暂无
中图分类号
学科分类号
摘要
The curve of energy calibration in the α particle energy range 4.01-8.77 MeB is constructed. The curve is usable for solutions of a liquid scintillator with different light absorption. Mechanisms of broadening and asymmetry of the α peaks of different actinides are studied. The LS α spectrometry possibilities are analyzed.
引用
收藏
相关论文
共 50 条
  • [21] IMPROVED LIQUID-SCINTILLATION COUNTING OF TRITIATED INULIN
    MOORE, PA
    CLINICAL CHEMISTRY, 1981, 27 (02) : 349 - 350
  • [22] SLOW-NEUTRON LIQUID-SCINTILLATION DETECTOR
    SWANK, RK
    NUCLEONICS, 1952, 10 (03): : 38 - 38
  • [23] ABSOLUTE LIQUID-SCINTILLATION COUNTING OF BETA EMITTERS
    GOLDSTEIN, G
    NUCLEONICS, 1965, 23 (03): : 67 - +
  • [24] COMMENTS ON TRITIUM MONITORING BY LIQUID-SCINTILLATION COUNTING
    PENG, CT
    HUA, RL
    APPLIED RADIATION AND ISOTOPES, 1987, 38 (06) : 492 - 494
  • [25] CONTRIBUTION TO LIQUID-SCINTILLATION COUNTING OF FILTER MATERIALS
    BUCHTELA, K
    TSCHURLO.M
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1973, 24 (09): : 531 - 533
  • [26] Alpha Liquid-Scintillation Spectrometry used for the Measurement of Uranium/Thorium-Disequilibria in Soil Samples
    Fueeg, B.
    Tschachtli, T.
    Kraehenbuehl, U.
    Radiochimica Acta, (78):
  • [27] Alpha liquid-scintillation spectrometry used for the measurement of uranium/thorium-disequilibria in soil samples
    Fueg, B
    Tschachtli, T
    Krahenbuhl, U
    RADIOCHIMICA ACTA, 1997, 78 : 47 - 51
  • [28] LIQUID-SCINTILLATION STANDARDIZATION OF TE-123M
    COURSEY, BM
    GOLAS, DB
    GRAY, DH
    HOPPES, DD
    SCHIMA, FJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 312 (1-2): : 121 - 123
  • [29] STANDARDIZATION OF TC-99 BY LIQUID-SCINTILLATION COUNTING
    COURSEY, BM
    GIBSON, JAB
    HEITZMANN, MW
    LEAK, JC
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1984, 35 (12): : 1103 - 1112
  • [30] MODIFICATIONS IN BIPHASIC LIQUID-SCINTILLATION VIAL SYSTEM FOR RADIOMETRY
    GANATRA, RD
    BUDDEMEYER, EU
    DEODHAR, MN
    NARKAR, AA
    POWAR, DM
    SHAH, DH
    JOURNAL OF NUCLEAR MEDICINE, 1980, 21 (05) : 480 - 483