Experimental investigation on the heat transfer characteristic of a cryogenic thermosyphon

被引:0
|
作者
Diao, Yan-Hua [1 ]
Wang, Qiu-Liang [2 ]
Zhao, Yao-Hua [1 ]
机构
[1] College of Architecture and Civil Engineering, Beijing University of Technology, Beijing 100124, China
[2] Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190, China
来源
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics | 2008年 / 29卷 / 11期
关键词
Capillary flow - Superconducting magnets - Thermosyphons - Cryogenics - Heat pipes - Siphons;
D O I
暂无
中图分类号
学科分类号
摘要
The heat pipe is an efficient heat transfer device. It has good application prospects in superconducting magnet cooling and space cryogenic heat transfer technology. The experimental investigation is described concerning the heat transport characteristics of a thermosyphon. The results show that the heat transfer performances of the thermosyphon has the advantage of copper solid conductor with the same volume. The thermosyphon could be used to cool down the superconducting magnet more quickly.
引用
收藏
页码:1898 / 1900
相关论文
共 50 条
  • [11] Experimental investigation of heat transfer characteristics of inclined aluminium two phase closed thermosyphon
    Mutalikdesai, Sachin V.
    Kate, Ajit M.
    Shinde, Tarang R.
    Kumar Gupta, Naveen
    Panchal, Hitesh
    Natrayan, L.
    Meena, Radhey Shyam
    Siddiqui, Md Irfanul Haque
    Patel, Anand
    Kumar, Abhinav
    KERNTECHNIK, 2023, 88 (06) : 632 - 641
  • [12] Experimental investigation of CO2 thermosyphon flow and heat transfer in the supercritical region
    Chen, Lin
    Deng, Bi-Li
    Zhang, Xin-Rong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 64 : 202 - 211
  • [13] Experimental study on heat transfer characteristics of thermosyphon radiator
    Sun, Zhi-Jian
    Wang, Li-Xin
    Wang, Yan
    Wu, Cun-Zhen
    Cen, Ke-Fa
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2007, 41 (08): : 1403 - 1405
  • [14] Impact of cooling condition and filling ratio on heat transfer limit of cryogenic thermosyphon
    Long, Z. Q.
    Zhang, P.
    CRYOGENICS, 2012, 52 (01) : 66 - 76
  • [15] Experimental study on heat transfer in an open thermosyphon (augmentation of heat transfer by air injection
    Imura, Hideaki
    Kozai, Hiroaki
    Heat Transfer - Japanese Research, 1988, 17 (05): : 17 - 31
  • [16] Experimental investigation on heat transfer characteristic of saturated boiling in round tube
    Luo, Feng
    Hedongli Gongcheng/Nuclear Power Engineering, 2015, 36 : 184 - 186
  • [17] Experimental investigation on heat transfer characteristics in cryogenic chilldown of a helically coiled tube
    Mohammed, Jesna
    Bindu, S. S.
    Mohizin, Abdul
    Roy, K. E. Reby
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2021, 46 (01):
  • [18] Experimental investigation on heat transfer characteristics in cryogenic chilldown of a helically coiled tube
    Jesna Mohammed
    S S Bindu
    Abdul Mohizin
    K E Reby Roy
    Sādhanā, 2021, 46
  • [19] Experimental investigation on air-cooling type loop thermosyphon thermal characteristic with serpentine tube heat exchanger
    He, Yichuan
    Hu, Chengzhi
    Li, Hongyang
    Hu, Xianfeng
    Tang, Dawei
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 138 : 52 - 60
  • [20] Experimental study of the dynamic heat transfer performance of a coaxial thermosyphon
    Yang, JH
    Li, Q
    Lu, WQ
    Li, ZY
    Li, Q
    Zhou, Y
    JOURNAL OF ENHANCED HEAT TRANSFER, 2005, 12 (04) : 315 - 325