Simulation and protection scheme of the large-sized turbo-generator with internal short circuit faults

被引:0
|
作者
Tu, L. [1 ]
Liu, W. [1 ]
Wu, J. [1 ]
Hu, M. [1 ]
机构
[1] North China Electric Power Univ., Beijing 100085, China
关键词
Computer simulation - Electric equipment protection - Machine windings - Short circuit currents;
D O I
暂无
中图分类号
学科分类号
摘要
The performances of the large-sized turbo-generator with the internal winding faults are simulated and verified by using the multi-loop theory, and further the protection schemes for the internal faults are also analyzed and evaluated. The results provide the reference for deploying the protection schemes for the internal faults.
引用
收藏
页码:11 / 15
相关论文
共 44 条
  • [1] Study on new leading-out mode of neutral points of large-sized turbo-generator
    Gui, L
    Wang, XH
    Sun, YG
    Wang, WJ
    ICEMS 2005: Proceedings of the Eighth International Conference on Electrical Machines and Systems, Vols 1-3, 2005, : 89 - 93
  • [2] Necessity of interturn short circuit protection for large-sized turbogenerators
    Zhao, Xiaodong
    Duan, Naixian
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 1999, 23 (11): : 39 - 41
  • [3] The main protection scheme of internal short circuit for generator of large-sized (above 600 MW) hydroelectric power station - Based on simulation for generators of Three Gorges hydroelectric power station
    Nengling, Tai
    Xianggen, Yin
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 1999, 23 (11):
  • [4] Analysis on stator circulating current characteristics under rotor short circuit faults of turbo-generator
    Wan, Shu-Ting
    He, Yu-Ling
    Tang, Gui-Ji
    Li, Yong-Gang
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (04): : 987 - 993
  • [5] A Stator Internal Short-Circuit Fault Protection Method for Turbo-Generator Based on Instantaneous Power Oscillation Ratio
    Qiao, Jian
    Yin, Xianggen
    Wang, Yikai
    Lu, Qinghui
    Tan, Liming
    Zhu, Lingjin
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2023, 38 (03) : 1903 - 1912
  • [6] ON SHORT CIRCUIT CURRENTS OF A LARGE TURBO-GENERATOR WITH MERCURY-ARC SELF-EXCITATION
    ZAKHARITKIN, MK
    ELECTRICAL TECHNOLOGY RUSSIA, 1968, 2 : 20 - +
  • [7] ANALYSIS AND SIMULATION ON THE EFFECT OF ROTOR INTERTURN SHORT CIRCUIT ON MAGNETIC FLUX DENSITY OF TURBO-GENERATOR
    He, Yu-Ling
    Ke, Meng-Qiang
    Tang, Gui-Ji
    Jiang, Hong-Chun
    Yuan, Xing-Hua
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2016, 67 (05): : 323 - 333
  • [8] Investigation on Rotor Vibration Characteristics of Turbo-generator under Air Gap Eccentricity and Rotor Short Circuit Composite Faults
    Wan, Shuting
    He, Yuling
    Tang, Guiji
    JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS, 2011, 32 (02): : 155 - 164
  • [9] Online Monitoring of Inter-turn Short Circuit Fault of Field Winding in Large Turbo-generator
    Qin, Ganghua
    Wang, Xin
    Jin, Yang
    Zhu, Qikang
    Yang, Shiyou
    2021 24TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2021), 2021, : 1619 - 1623
  • [10] Influence of stator internal short-circuit fault on rotor eddy current losses in nuclear power turbo-generator
    Zhao H.-S.
    Ge B.-J.
    Tao D.-J.
    Han J.-C.
    Wang L.-K.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2018, 22 (08): : 17 - 25