共 50 条
Comparison of two models of artificial insemination pipettes in the catheterization of the cervical canal in sheep
被引:0
|作者:
Gavancho F.R.
[1
]
Greco J.M.
[1
]
Chipana C.C.
[2
]
机构:
[1] Laboratorio Central, Facultad de Ciencias Agropecuarias, Universidad Alas Peruanas, Pachacamac, Lima
[2] Departamento de Producción, Camal de Yerbateros, Lima
来源:
|
1600年
/
Universidad Nacional Mayor de San Marcos卷
/
28期
关键词:
Catheterization;
Cervix;
Insemination pipette;
Sheep;
D O I:
10.15381/rivep.v28i1.12939
中图分类号:
学科分类号:
摘要:
The aim of this study was to compare the depth of penetration of a dye into the cervical canal in sheep, simulating an insemination by using a traditional artificial insemination (AI) gun and one with a special design that has at the end an inflatable balloon that prevents reflux of dye. Eighty reproductive tracts of non-pregnant ewes were collected from the local slaughterhouse in Lima, Peru and randomly distributed for catheterization with one of the two AI guns, depositing 0.5 ml of methylene blue. The balloon of the second AI gun was inflated before depositing the die. Subsequently, the cervical canal was exposed and the depth of entry of the AI guns and the dye were measured considering the edge of the first cervical ring as zero (0). Both AI guns penetrated 19.9 + 9.6. The die reached the same depth with the traditional gun and 60.0 + 9.7 mm with the modified pipette (p<0.05). It is concluded that by using the modified pipette is possible to deposit a fluid more closely to the uterus.
引用
收藏
页码:214 / 218
页数:4
相关论文