Multilayered implantable antenna biosensor for continuous glucose monitoring: Design and analysis

被引:0
|
作者
Khadase R.B. [1 ]
Nandgaonkar A. [1 ]
Iyer B. [1 ]
Wagh A. [2 ]
机构
[1] Department of E & TC Engineering, Dr. B. Ambedkar Technological University, Lonere
[2] Directorate of Technical Education, Maharashtra, Mumbai
关键词
20;
D O I
10.2528/PIERC21052203
中图分类号
学科分类号
摘要
This article reports a multilayer implantable biosensor for a continuous glucose monitoring system, tested on rats to determine the relationship between intravenous glucose level and resonance frequency of implant antenna sensor. An implantable antenna sensor with the volume 330.9 mm3 is tested in three rats as an animal model. This antenna biosensor operates in the Medical Implant Communication Service frequency band (402–405 MHz) with the simulated and measured maximum gains of −13.33 and −21.1 dB, respectively. The specific absorption rate obtained is within the standard limits. An oral glucose tolerance test is proposed to obtain the variation in blood glucose level in the animal’s body during measurement. The resonance frequency shift and the corresponding blood glucose level are observed at a regular interval of 30 minutes. A frequency shift of 4.94 kHz per mg/dL is observed. Also, the results related to the reflection coefficient and the factors affecting sensor performance are discussed. The biosensor performance is validated using the proposed simple linear regression model. © 2021, Electromagnetics Academy. All rights reserved.
引用
收藏
页码:173 / 184
页数:11
相关论文
共 50 条
  • [21] Review of the Long-Term Implantable Senseonics Continuous Glucose Monitoring System and Other Continuous Glucose Monitoring Systems
    Joseph, Jeffrey I.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (01): : 167 - 173
  • [22] An Implantable RFID Sensor Tag toward Continuous Glucose Monitoring
    Xiao, Zhibin
    Tan, Xi
    Chen, Xianliang
    Chen, Sizheng
    Zhang, Zijian
    Zhang, Hualei
    Wang, Junyu
    Huang, Yue
    Zhang, Peng
    Zheng, Lirong
    Min, Hao
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2015, 19 (03) : 910 - 919
  • [23] A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
    Ahmadi, Mohammad Mahdi
    Jullien, Graham A.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2009, 3 (03) : 169 - 180
  • [24] Towards Smart Tattoos: Implantable Biosensors for Continuous Glucose Monitoring
    Heo, Yun Jung
    Takeuchi, Shoji
    ADVANCED HEALTHCARE MATERIALS, 2013, 2 (01) : 43 - 56
  • [25] THE STRUCTURAL DESIGN AND ANALYSIS OF A BLOOD GLUCOSE MONITORING BIOSENSOR BASED ON OPTICAL METHOD
    Shi, K.
    Chen, Z. B.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2016, 118 : 101 - 101
  • [26] Evaluation of a minimally invasive glucose biosensor for continuous tissue monitoring
    Sharma, Sanjiv
    Huang, Zhenyi
    Rogers, Michelle
    Boutelle, Martyn
    Cass, Anthony E. G.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (29) : 8427 - 8435
  • [27] Design and Experimental Validation of a Noninvasive Glucose Monitoring System Using RF Antenna-Based Biosensor
    Mahnashi, Yaqub
    Qureshi, Khurram Karim
    Al-Shehri, Abdullah A.
    Attia, Hussein
    IEEE SENSORS JOURNAL, 2023, 23 (03) : 2856 - 2864
  • [28] Evaluation of a minimally invasive glucose biosensor for continuous tissue monitoring
    Sanjiv Sharma
    Zhenyi Huang
    Michelle Rogers
    Martyn Boutelle
    Anthony E. G. Cass
    Analytical and Bioanalytical Chemistry, 2016, 408 : 8427 - 8435
  • [29] Implantable small ultra-wideband circularly polarized antenna design for continuous blood pressure monitoring
    Zhiwei Song
    Xianren Zheng
    Youwei Shi
    Yuchao Wang
    Scientific Reports, 14 (1)
  • [30] Fully integrated flexible biosensor for wearable continuous glucose monitoring
    Jin, Xiaofeng
    Li, Guanhua
    Xu, Tailin
    Su, Lei
    Yan, Dan
    Zhang, Xueji
    BIOSENSORS & BIOELECTRONICS, 2022, 196