The study on the MRTD measurement system of medical infrared thermal imager based on sub-pixel edge detection algorithm

被引:0
|
作者
Miao C. [1 ]
Wenjie C. [1 ]
Qinghua Y. [2 ]
机构
[1] Changchun University of Science and Technology, Changchun, 130022, Jilin
[2] Changchun University Of Technology, Changchun, 130012, Jilin
来源
Wenjie, Cui (79816540@qq.com) | 1600年 / Science and Engineering Research Support Society卷 / 11期
关键词
CCD; Image processing; MRTD; The infrared thermal imager;
D O I
10.14257/ijmue.2016.11.7.12
中图分类号
学科分类号
摘要
MRTD (minimum resolvable temperature difference) is an important parameter to evaluate the infrared thermal imager. MRTD is not only related to the spatial resolution of the system, but also to many factors such as optical system, detector array and so on. The measurement technique and principle of the medical infrared thermal imager’s MRTD is deeply analyzed, and the MRTD measurement model is established in this paper. The MRTD measurement system of infrared thermal imager based on CCD imaging technology is designed. CCD is used to carry on the interpretation of temperature difference in this system instead of the human eye, which can avoid the effect of some factors on the subjective image quality evaluation, such as the contrast, the human interference flaw and so on. The sub-pixel edge detection algorithm is used to deal with the four-bar target image, which can effectively suppress the interface of the random noise on four-bar target image. The experimental results show that the MRTD testing accuracy of the system can reach 0.055°C. © 2016 SERSC.
引用
收藏
页码:119 / 126
页数:7
相关论文
共 50 条
  • [31] An adaptive sub-pixel edge detection method based on improved Zernike moment
    Mo J.
    Yan H.
    Liu J.
    International Journal of Wireless and Mobile Computing, 2022, 22 (02): : 140 - 147
  • [32] Hyperbolic tangent algorithm for periodic effect cancellation in sub-pixel resolution edge displacement measurement
    Cantatore, Angela
    Cigada, Alfredo
    Sala, Remo
    Zappa, Emanuele
    MEASUREMENT, 2009, 42 (08) : 1226 - 1232
  • [33] Sub-Pixel counting based diameter measurement algorithm for industrial Machine vision
    Poyraz, Ahmet Gokhan
    Kacmaz, Mehmet
    Gurkan, Hakan
    Dirik, Ahmet Emir
    MEASUREMENT, 2024, 225
  • [34] A new liquid level measuring system of standard metal tank based on sub-pixel edge detection
    Zhao, Cuilian
    Chen, Yu
    2007 IEEE INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION, VOLS 1-7, 2007, : 1327 - 1332
  • [35] Sub-pixel land-cover change detection based on pixel unmixing and EM algorithm
    Wu, Ke
    Ma, Yue
    Zhang, Liang-pei
    2015 7TH WORKSHOP ON HYPERSPECTRAL IMAGE AND SIGNAL PROCESSING: EVOLUTION IN REMOTE SENSING (WHISPERS), 2015,
  • [36] Sub-pixel retinal vessel tracking and measurement using modified Canny edge detection method
    Chang, Samuel H.
    Shim, Duh-Sun
    JOURNAL OF IMAGING SCIENCE AND TECHNOLOGY, 2008, 52 (02)
  • [37] A robust sub-pixel edge detection method of infrared image based on tremor-based retinal receptive field model
    Gao, Kun
    Yang, Hu
    Chen, Xiaomei
    Ni, Guoqiang
    INFRARED MATERIALS, DEVICES, AND APPLICATIONS, 2007, 6835
  • [38] The Sub-pixel Edge Detection Based on Improved Zernike Moment for Brain CT Image
    You, Ye
    INTERNATIONAL CONFERENCE ON ELECTRONIC INFORMATION TECHNOLOGY AND INTELLECTUALIZATION (ICEITI 2016), 2016, : 123 - 128
  • [39] High-Precision Camera Calibration Method Based on Sub-Pixel Edge Detection
    Lou Qun
    Lu Junhao
    Wen Lihua
    Xiao Jinyou
    Zhang Guangxi
    Hou Xiao
    ACTA OPTICA SINICA, 2022, 42 (20)
  • [40] Method of straight edge detection with sub-pixel localization based on SUSAN and Hough transform
    School of Mechanical Engineering and Automation, Beihang University, Beijing 100083, China
    不详
    Guangdian Gongcheng, 2008, 6 (89-94):