Long-term effect analysis of AC600 passive containment cooling system

被引:0
|
作者
Yu, Ji-Yang [1 ]
Li, Kun [1 ]
Jia, Bao-Shan [1 ]
机构
[1] Dept. of Eng. Phys., Tsinghua Univ., Beijing 100084, China
来源
关键词
Computer software - Containment vessels - Diffusion - Loss of coolant accidents - Three dimensional - Turbulence;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presented long-term effect analysis of AC600 passive containment cooling system under loss-of-coolant accident (LOCA). A special code PCCSAC-3D code, was used to analyze the performance of the AC600 passive containment cooling system (PCCS) developed by Tsinghua University. The code classifies the working fluid in the containment into steam, uncondensable air, continuous liquid state water and discontinuous water and includes k-Ε turbulence model and diffusion model for main gas flow. The code considers non-uniform factors of space carefully. It can be used to analyze the majority physical phenomenon of the AC600 PCCS accurately. The conclusion is that the PCCS can ensure the integrality of the AC600 containment in the long-term.
引用
收藏
页码:60 / 62
相关论文
共 50 条
  • [21] Study on the Behaviors of a Conceptual Passive Containment Cooling System
    Wang, Jianjun
    Guo, Xueqing
    Yu, Shengzhi
    Cai, Baowei
    Sun, Zhongning
    Yan, Changqi
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2014, 2014
  • [22] The modeling of passive containment cooling system and sensitivity analysis using the SPRUCE code
    Zhang Z.
    Zhao Z.
    Yang F.
    Guo C.
    Chen P.
    International Journal of Advanced Nuclear Reactor Design and Technology, 2023, 5 (02): : 72 - 76
  • [23] Research of aerosol removal by passive containment cooling system
    Ou P.
    Chen P.
    International Journal of Advanced Nuclear Reactor Design and Technology, 2023, 5 (04): : 200 - 206
  • [24] Modeling of ESBWR Passive Containment Cooling System with MELCOR
    Sevon, Tuomo
    22ND INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE, (NENE 2013), 2013,
  • [25] Development of a Simplified Model for the Passive Containment Cooling System
    Chen, Meilan
    PROCEEDINGS OF THE 20TH PACIFIC BASIN NUCLEAR CONFERENCE, VOL 1, 2017, : 295 - 307
  • [26] Effects of outlet height on passive containment cooling system
    Liu, Youhong
    Sun, Mingyue
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2015, 27 (12):
  • [27] The Outside Transport Phenomena of the Passive Containment Cooling System
    Li, Cheng
    Fan, Huanran
    Zhao, Ruichang
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 4, 2014,
  • [28] Long-Term Evaluation of Permafrost Passive Cooling Features in Interior Alaska
    Goering, Douglas J.
    Saboundjian, Steve
    COLD REGIONS ENGINEERING 2024: SUSTAINABLE AND RESILIENT ENGINEERING SOLUTIONS FOR CHANGING COLD REGIONS, 2024, : 262 - 272
  • [29] Effect of air temperature on passive containment cooling system reliability in AP1000
    Yu, Yu
    Ma, Nan
    Wang, Shengfei
    Niu, Fenglei
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART O-JOURNAL OF RISK AND RELIABILITY, 2015, 229 (04) : 310 - 318
  • [30] A PANDA integral test on the effect of light gas on a Passive Containment Cooling System (PCCS)
    Paladino, Domenico
    Auban, Olivier
    Huggenberger, Max
    Dreier, Joerg
    NUCLEAR ENGINEERING AND DESIGN, 2011, 241 (11) : 4551 - 4561