Experimental investigation on heat transfer and friction factor for an inclined spherical ball roughened solar air heater

被引:0
|
作者
Murmu R. [1 ]
Kumar P. [1 ]
Singh H.N. [1 ]
机构
[1] Mechanical Engineering Department, NIT Jamshedpur, Jharkhand
来源
Instrumentation Mesure Metrologie | 2018年 / 17卷 / 01期
关键词
Angle of attack; Height to diameter ratio; Relative roughness height; Relative roughness pitch; Solar energy; Spherical ball;
D O I
10.3166/I2M.17.7-36
中图分类号
学科分类号
摘要
The purpose of present investigation is to determine the results of heat transfer and frictional losses for an inclined spherical ball roughened solar air heater. Experimentation was conducted under actual outdoor condition at the test rig designed and fabricated at the terrace of the Mechanical Engineering Department, NIT Jamshedpur, India. To show the effect of ever-changing environmental variables like solar radiation, wind velocity, ambient temperature, etc, on the heat transfer results, the readings were noted for every 15 minutes in the experimental hours 10:00 to 15:00 hours. The present paper deals with the experimental results drafted in the form of rise in Nusselt number (Nu) and friction factor (f) for spherical ball roughened solar air heater (SAH) over those of smooth ones. Flow and roughness geometrical parameters have been varied as relative roughness pitch (p/e) 9-18, relative roughness height (e/Dh) 0.024-0.040, ball’s height to diameter ratio (e/db) 0.5-2, angle of attack (α) 35-75 and Reynolds no (Re) 2500-18500. Parametric analysis has also been made and the effects of these parameters on Nu and f characteristics have been shown. This article reveals that maximum augmentation in ‘Nu’ & ‘f’ for varying ‘p/e’, ‘e/Dh’ & ‘e/db’ and ‘α’ was respectively found to be of the order of 2.1 to 3.54 times, 1.87 to 3.21 times and 2.89 to 3.27 & 1.74 to 3.56 times for ‘Nu’ and 0.84 to 1.79 times, 1.46 to 1.91 times, 1.67 to 2.34 times & 1.21 to 2.67 times for ‘f’ in compared to non-roughened duct. The optimum roughness parameters found under present investigation is p/e = 15, e/Dh = 0.036, e/db = 1 and α = 55. The findings of this research may serve as a criteria to determine thermal and thermohydraulic performance of such roughened solar air heaters and to understand the magnitude of useful heat gain choosing such roughness geometry. © 2018 Lavoisier.
引用
收藏
页码:7 / 36
页数:29
相关论文
共 50 条
  • [41] Enhancement of Convective Heat Transfer Coefficient in Solar Air Heater of Roughened Absorber Plate
    Katekar, A. Vikrant
    VithalKar, B. Ankur
    Kale, C. Bhojraj
    2009 SECOND INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN ENGINEERING AND TECHNOLOGY (ICETET 2009), 2009, : 812 - +
  • [42] Heat transfer, friction factor and thermal performance of three sides artificially roughened solar air heaters
    Behura, Arun K.
    Prasad, B. N.
    Prasad, L.
    SOLAR ENERGY, 2016, 130 : 46 - 59
  • [43] Experimental Investigation on Heat Transfer Enhancement by Swirl Generators in a Solar Air Heater Duct
    Bhattacharyya, Suvanjan
    Chattopadhyay, Himadri
    Bandyopadhyay, Satyaki
    Roy, Sourodeep
    Pal, Anirban
    Bhattacharjee, Sarbojit
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2016, 34 (02) : 191 - 196
  • [44] EXPERIMENTAL INVESTIGATION ON THE HEAT TRANSFER OF A PORTABLE FORCED-CONVECTION SOLAR AIR HEATER
    Pakdaman, Mohammad Fakoor
    Izadi, Pejman Zohorian
    Azari, Mohammad Javadinia
    Lashkari, Amir
    PROCEEDINGS OF THE ASME 10TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS, 2010, VOL 2, 2010, : 573 - 582
  • [45] Heat transfer and friction characteristics of impinging jet solar air heater
    Chauhan, Ranchan
    Thakur, N. S.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2012, 4 (04)
  • [46] Investigation on influence of dimpled surfaces on heat transfer enhancement and friction factor in solar water heater
    Manoram, R. B.
    Moorthy, R. Sathiya
    Ragunathan, R.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (02) : 541 - 558
  • [47] Investigation on influence of dimpled surfaces on heat transfer enhancement and friction factor in solar water heater
    R. B. Manoram
    R. Sathiya Moorthy
    R. Ragunathan
    Journal of Thermal Analysis and Calorimetry, 2021, 145 : 541 - 558
  • [48] Heat transfer enhancement due to a staggered element using liquid crystal thermography in an inclined discrete rib roughened solar air heater
    Rathor, Yogendra
    Aharwal, K. R.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2020, 118 (118)
  • [49] THEORETICAL INVESTIGATION OF A SOLAR AIR HEATER ROUGHENED BY RIBS AND GROOVES
    Yildirim, C.
    Ozdil, N. F. Tumen
    JOURNAL OF THERMAL ENGINEERING, 2018, 4 (01): : 1702 - 1712
  • [50] Thermal performance investigation of frustum roughened solar air heater
    Singh, Dharam
    Kumar, Vikash
    SOLAR ENERGY, 2023, 255 : 339 - 354