Optical design of three-mirror telescope system

被引:0
|
作者
School of Information Science and Technology, Beijing Institute of Technology, Beijing 100081, China [1 ]
机构
来源
Guangxue Jishu | 2007年 / 2卷 / 170-172+176期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A configuration called three-mirror anastigmat (TMA) system, which is coaxial system used in off-axis situation, is discussed. TMA is made up of three conic mirrors, a deform mirror and a fast steering mirror. The initial configuration is obtained according to the theory of the first order aberrations, and then optimizes with the software of automation optical design Zemax. The exit pupil can be located at the deform mirror to correct the residual aberrations caused by the primary mirror. Two methods are applied to meet this requirement. The image quality of the optical system designed is near the diffraction-limited, and can satisfy the requirement of the usage.
引用
收藏
页码:170 / 172
相关论文
共 50 条
  • [31] Alignment of a three-mirror telescope using the sine condition test
    Sommitz, David
    Dubin, Matthew
    OPTICAL SYSTEM ALIGNMENT, TOLERANCING, AND VERIFICATION XII, 2018, 10747
  • [32] Parametric synthesis of three-mirror optical systems based on a two-mirror system
    Ermolaeva, E. V.
    Zverev, V. A.
    Podgornykh, Yu. A.
    Timoshchuk, I. N.
    JOURNAL OF OPTICAL TECHNOLOGY, 2013, 80 (11) : 670 - 679
  • [33] Stray light removing design and simulation of the three-mirror optical system used in field bias
    Yan, Peipei
    Fan, Xuewu
    Zou, Gangyi
    Yang, Lihua
    He, Jianwei
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2011, 40 (10): : 1997 - 2002
  • [34] The research of filtering on images with noises of the three-mirror aperture optical system
    Jun, Wang
    Wu Quanying
    Fan Junliu
    Wang Youqing
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS III, 2014, 9276
  • [35] Three-mirror anastigmat telescope with an unvignetted flat focal plane
    Nariai, K
    Iye, M
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 2005, 57 (02) : 391 - 397
  • [36] Radiation noise in a three-mirror system
    A. A. Kurbatov
    E. A. Titov
    Optics and Spectroscopy, 2002, 93 : 315 - 320
  • [37] A common aperture coaxial three-mirror optical system with high resolution
    Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun
    Jilin
    130033, China
    不详
    100049, China
    Zhongguo Jiguang, 11
  • [38] Optical design of a compact and anastigmatic off-axis three-mirror system using freeform surfaces
    Alvarado-Martinez, Jorge
    Granados-Agustin, Fermin-Salomon
    Vazquez-Montiel, Sergio
    Vazquez-Villa, Alexis
    Cornejo-Rodriguez, Alejandro
    OPTICAL ENGINEERING, 2021, 60 (05)
  • [39] Design of Off-axis Three-mirror System with Zernike Surface
    Gong Guangbiao
    Wei Jun
    Shen Weimin
    6TH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2010, 7544
  • [40] Design of Off-Axis Three-Mirror Optical System Based on Free-Form Surface
    Li Junyang
    Li Wenqiang
    You, Long
    Liang, Zhou
    Yang, Gao
    LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (09)