Development of a New PET Detector with Depth-Encoding Capability Using Wavelength-Shifting Fiber Readout

被引:3
|
作者
An S.J. [1 ]
Chung Y.H. [2 ]
Min E. [3 ]
Lee S.-J. [2 ]
Lee J. [2 ]
Kim Y. [4 ]
Lee K. [5 ]
机构
[1] Korea Atomic Energy Research Institute, Daejeon
[2] Department of Radiological Science, Yonsei University, Wonju
[3] Korea University, Seoul
[4] Nucare Medical System, Incheon
[5] Department of Radiologic Science, Korea University, Seoul
来源
| 1600年 / Institute of Electrical and Electronics Engineers Inc.卷 / 01期
关键词
Depth of interaction (DOI); dual-ended-scintillator (DES) readout; silicon photomultiplier (SiPM); small-animal positron emission tomography (PET); wavelength-shifting fiber;
D O I
10.1109/TNS.2017.2679178
中图分类号
学科分类号
摘要
A new concept of positron emission tomography detector with depth-encoding capability is proposed and developed for small-animal imaging. The detector module is based on wavelength-shifting (WLS) fibers coupled to both sides of a scintillator array having a unique pattern. The scintillator array consists of 15× 15 lutetium yttrium orthosilicate crystals with three different heights: 18, 20, and 22 mm. On the every other line, crystals having 2 mm shorter height are arranged to the x -direction on the top and the y -direction on the bottom of the array to make grooves for WLS fiber insertion. WLS fibers are inserted into these grooves and one end of each WLS fiber is coupled to a single channel silicon photomultiplier to detect scintillating lights trapped in the fiber. Field-programmable gate array combined 64-channel data acquisition (DAQ) system is used for DAQ and data processing, such as position, energy, and time decoding. The performance parameters, including pixel identification, energy resolution, depth of interaction (DOI) resolution, and timing resolution, were evaluated for proof of concept. The results proved that the design of detector allows not only to provide reasonable DOI information, but also to reduce the number of channels for sensors and electronics dramatically. © 2017 IEEE.
引用
收藏
页码:206 / 211
页数:5
相关论文
共 50 条
  • [1] Comparison of wavelength-shifting fiber types and methods of ribbon assembly for the depth-encoding anger detector
    Matthews, KL
    Leonard, SM
    Ordonez, CE
    Chang, W
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1933 - 1936
  • [2] Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depth-encoding PET detector
    Du, Huini
    Yang, Yongfeng
    Cherry, Simon R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (09): : 2499 - 2514
  • [3] Comparison of four depth-encoding PET detector modules with wavelength shifting (WLS) and optical fiber read-out
    Du, Huini
    Yang, Yongfeng
    Cherry, Simon R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (07): : 1829 - 1842
  • [4] A liquid scintillator detector with wavelength-shifting fibre readout
    Doucet, M
    Fabre, JP
    Grégoire, G
    Panman, J
    Zucchelli, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 453 (03): : 545 - 552
  • [5] Development of a high-resolution PET detector using LSO and wavelength-shifting fibers
    Worstell, W
    Johnson, O
    Zawarzin, V
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1756 - 1760
  • [6] Performance study of a prototype PET scanner using CsI(Na) scintillator with wavelength-shifting fiber readout
    Zavarzin, V
    Johnson, O
    Kudrolli, H
    Worstell, W
    SCIFI 97: CONFERENCE ON SCINTILLATING FIBER DETECTORS, 1998, 450 : 489 - 494
  • [7] Development of a wavelength-shifting fiber-based photon detector for LBNE
    Wasserman, R.
    Buchanan, N.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [8] Performance results of a prototype depth-encoding PET detector
    Meng, LJ
    Ramsden, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1011 - 1017
  • [9] Performance results of a prototype depth-encoding PET detector
    Meng, LJ
    Ramsden, D
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 929 - 933
  • [10] A practical block detector for a depth-encoding PET camera
    Rogers, JG
    Moisan, C
    Hoskinson, EM
    Andreaco, MS
    Williams, CW
    Nutt, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) : 3240 - 3248