Performance results of a prototype depth-encoding PET detector

被引:10
|
作者
Meng, LJ [1 ]
Ramsden, D [1 ]
机构
[1] Univ Southampton, Dept Phys & Astron, Southampton SO17 1BJ, Hants, England
关键词
D O I
10.1109/23.856540
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The results of a feasibility study for a high-resolution PET detector system are presented. The detector is based on the use of etched LSO scintillation crystals viewed from just one end. We have demonstrated that this configuration yields Depth-of-Interaction (DOI) information whilst also preserving good energy and coincidence-time resolution. A prototype detector was built using a 4x4 crystal array coupled to 61-pixel hybrid photodiodes. The measurements demonstrate a. DOI resolution of 5 similar to 7mm FWHM in a 30mm deep detector. The signal level was measured to be in the range 250 to 600 photoelectrons depending on the location of the 511 keV energy deposit in the crystal. A resolving-time of less than 5ns FWHM was estimated based on indirect measurements. The technique depends on the assumption that all of the events detected above a selected threshold value are, in fact, full-energy deposits. The validity of this assumption and the impact of the photons scattered in the object have been studied using a Monte Carlo simulation of the proposed small animal PET imager.
引用
收藏
页码:1011 / 1017
页数:7
相关论文
共 50 条
  • [1] Performance results of a prototype depth-encoding PET detector
    Meng, LJ
    Ramsden, D
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 929 - 933
  • [2] Performance results of a prototype depth-encoding PET detector
    Meng, L.J.
    Ramsden, D.
    IEEE Transactions on Nuclear Science, 2000, 47 (3 III) : 1011 - 1017
  • [3] A practical block detector for a depth-encoding PET camera
    Rogers, JG
    Moisan, C
    Hoskinson, EM
    Andreaco, MS
    Williams, CW
    Nutt, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) : 3240 - 3248
  • [4] Experimental and simulation results with the Depth-encoding Anger Detector
    Matthews, KL
    Leonard, SM
    Kelly, LA
    Ordonez, CE
    Chang, W
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2361 - 2365
  • [5] Performance measurements of a depth-encoding TraPET detector module
    Chung, Y. H.
    Lee, C. Y.
    Baek, C. -H.
    An, S. J.
    Kim, H. Il
    Choi, Y.
    Kang, J.
    Hu, W.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [6] A depth-encoding PET detector for high resolution PET using 1 mm SiPMs
    Du, Junwei
    Bai, Xiaowei
    Cherry, Simon R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (16):
  • [7] Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout
    Ren, Silin
    Yang, Yongfeng
    Cherry, Simon R.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [8] A Depth-Encoding PET Detector Inserting Glass Plate Between Crystal Layers
    Kang, Jihoon
    Choi, Yong
    Kim, Kyu Bom
    Jung, Jin Ho
    Hu, Wei
    Chung, Yong Hyun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (03) : 1059 - 1065
  • [9] A Depth-Encoding PET Detector Inserting Glass Plate Between Crystal Layers
    Kang, Jihoon
    Choi, Yong
    Jung, Jin Ho
    Hu, Wei
    Lim, Hyun Keong
    Kim, Byung-Tae
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2859 - 2864
  • [10] Monte Carlo modeling of a novel depth-encoding PET detector with DETECT2000
    Seung-Jae Lee
    Yong Hyun Chung
    Su Jung An
    Journal of the Korean Physical Society, 2016, 69 : 1356 - 1361