Real-time metering method for dynamic flow of natural gas injector

被引:0
|
作者
Peng Y. [1 ]
Wu Z. [1 ]
Chen X. [1 ]
Huang Y. [2 ]
机构
[1] School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou
[2] Fujian Lijia Co., Ltd., Zhangzhou
关键词
Calibration; Double buffer tank; Dynamic flow; Metering; Natural gas injector;
D O I
10.19650/j.cnki.cjsi.J1702078
中图分类号
学科分类号
摘要
The dynamic flow metering for natural gas injector provides the basis for accurate supply of natural gas for diesel/natural gas dual-fuel engines. According to the measuring principle of differential pressure flow-meter and the possible reasons resulting in pressure pulsation of natural gas supply, main factors affecting the measurement accuracy of flow-meter are analyzed. A scheme of natural gas supply for double buffer tank device is proposed. Then, under two kinds of natural gas supply schemes, flow metering models for natural gas injector are established by use of AMESim software. The effect of pipeline pressure pulsation on the flow of injection valve is researched. Moreover, the simulation results demonstrate that the maximum pressure difference of the injector with the double buffer tanks is 90% lower than that of the ordinary supply system, and the relative deviation of the mean value is reduced by 74.3%. Through building the test platform, experimental results clearly evidence that the natural gas supply system with double buffer tanks significantly improves the injector's stability and the metering precision of the dynamic flow. © 2018, Science Press. All right reserved.
引用
收藏
页码:11 / 17
页数:6
相关论文
共 17 条
  • [11] Brinkhorst S., Lavante E., Wendt G., Experimental and numerical investigation of the cavitation-induced choked flow in a herschel venturi-tube, Flow Measurement and Instrumentation, 54, pp. 56-67, (2017)
  • [12] Pramana P.A.A., Kurniadi D., Siregar P.I., Theoretical dynamic modeling of coriolis mass flowmeter arcuate type for fluctuation flow, 3rd International Conference on Instrumentation Control and Automation, pp. 57-62, (2013)
  • [13] Pramana P.A.A., Kurniadi D., Siregar P.I., Dynamic pressure modeling of damper system for fluctuation flow, 3rd International Conference on Instru-Mentation, Communications, Information Technology and Biomedical Engineering, pp. 373-376, (2013)
  • [14] Qian F.P., Huang X.W., Zhang M.Y., Study of gas shortcut flow rate in cyclone with different inlet section angles using response surface methodology, International Journal of Chemical Reactor Engineering, 7, 1, pp. 91-97, (2009)
  • [15] Ouazzane A.K., Benhadj R., Flow conditioners design and their effects in reducing flow metering errors, Sensor Review, 22, 3, pp. 223-231, (2002)
  • [16] Wang B.N., Wang R.J., Wang L.M., Et al., On the choice and determination of design parameters for laminar flow meters, Chinese Journal of Scientific Instrument, 21, 5, pp. 474-476, (2000)
  • [17] Zhejiang Provincial Administration of Standard Measure- ment, JJG736-1991 verification method of laminar flow sensor, (2005)