Real-time metering method for dynamic flow of natural gas injector

被引:0
|
作者
Peng Y. [1 ]
Wu Z. [1 ]
Chen X. [1 ]
Huang Y. [2 ]
机构
[1] School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou
[2] Fujian Lijia Co., Ltd., Zhangzhou
关键词
Calibration; Double buffer tank; Dynamic flow; Metering; Natural gas injector;
D O I
10.19650/j.cnki.cjsi.J1702078
中图分类号
学科分类号
摘要
The dynamic flow metering for natural gas injector provides the basis for accurate supply of natural gas for diesel/natural gas dual-fuel engines. According to the measuring principle of differential pressure flow-meter and the possible reasons resulting in pressure pulsation of natural gas supply, main factors affecting the measurement accuracy of flow-meter are analyzed. A scheme of natural gas supply for double buffer tank device is proposed. Then, under two kinds of natural gas supply schemes, flow metering models for natural gas injector are established by use of AMESim software. The effect of pipeline pressure pulsation on the flow of injection valve is researched. Moreover, the simulation results demonstrate that the maximum pressure difference of the injector with the double buffer tanks is 90% lower than that of the ordinary supply system, and the relative deviation of the mean value is reduced by 74.3%. Through building the test platform, experimental results clearly evidence that the natural gas supply system with double buffer tanks significantly improves the injector's stability and the metering precision of the dynamic flow. © 2018, Science Press. All right reserved.
引用
收藏
页码:11 / 17
页数:6
相关论文
共 17 条
  • [1] Oil and Natural Gas Corporation of National Energy Administration, Development Report of Natural Gas in China(2016), (2016)
  • [2] Li J.Y., Meng X.F., Dong D.F., Dynamic measurement method of gas flow rate at low pressure and wide temperature, Transactions of the Chinese Society of Agricultural Engineering, 28, 20, pp. 217-222, (2012)
  • [3] De Oliveira E., Simplified calibration methodology of chromatographs used in custody transfer measurements of natural gas, Metrology & Measurement Systems, 19, 2, pp. 405-416, (2012)
  • [4] Cui Y.H., Tang Z.A., Yu J., Et al., Design of a dynamic high-precision characterizing system for gas sensors, Chinese Journal of Scientific Instrument, 31, 10, pp. 2180-2185, (2010)
  • [5] Sun M.S., Wang F.M., Liu W., Et al., Novel application of gas chromatography in measurement of gas flow rate, Flow Measurement and Instrumentation, 50, pp. 245-251, (2016)
  • [6] Yu H.S., Zhang T., Xu W.D., Influence of orifice chamfering on the flow field characteristic of multi-hole orifice flowmeter, Journal of Electronic Measurement and Instrumentation, 29, 9, pp. 1356-1364, (2015)
  • [7] Xu W.D., Zhang T., Bi Y., Et al., Analysis the compressibility impact of gas on vortex flowmeter measurement performance, Journal of Electronic Measurement and Instrumentation, 27, 9, pp. 797-802, (2013)
  • [8] Yang G.F., Xu J.B., The buffer is a simple device for reducing the pulsating flow, City Gas, 9, pp. 10-13, (2001)
  • [9] Zhu Y., Study on the measurement error of differential pressure flowmeter in pulsating flow, Chinese Journal of Scientific Instrument, 27, 8, pp. 894-897, (2006)
  • [10] Zhou T., Ji H., Huang Z., Et al., On differential pressure fluctuation signals of gas-liquid two-phase flow in small- size pipe, 35th Chinese Control Conference, pp. 5056-5060, (2016)