New method used to measure corneal elastic modulus

被引:0
|
作者
Wu, Ling [1 ]
Xie, Yi [1 ]
Fan, Yu-Bo [1 ,2 ]
Huang, Xue-Jin [1 ]
Luo, Ying-Cun [3 ]
机构
[1] Biomechanical Eng. Lab., Sichuan Univ., Chengdu 610065, China
[2] Bioengineering Dept., Beihang Univ., Beijing 100083, China
[3] Grade 2005 Yuan Pei College, Beijing Univ., Beijing 100083, China
来源
| 2008年 / Editorial Department of Journal of Sichuan University卷 / 40期
关键词
Finite element method - Hydrostatic pressure - ABAQUS - Ablation - Excimer lasers;
D O I
暂无
中图分类号
学科分类号
摘要
In vitro, a new method was used to measure corneal elastic modulus of an integrity rabbit cornea, and keratectomy protrusive displacement and stress changes were contrasted. In ex vivo to research biomechanical changes in the cornea of rabbits, excimer laser incision was performed in laser in situ keratomileusis. In the condition of hydrostatic pressure on the corneal inner surface, three corneas such as integrity, 1/3 ablation and 1/2 ablation in thickness and 6 mm diameter in central regions were scanned, and the protusive displacement in different corneal centers was calculated. Using Abaqus finite element software to establish the corresponding models, the rabbit corneal elastic modulus with accessed protrusive displacement were calculated. Calculated rabbit corneal elastic modulus increases with increased keratectomy volume. The tendency of the elastic modulus is consistent with the clinical detection. The more stress and the more displacement is in the model of the thinner central region. The displacement and stress are not rapidly changing in ablation border.
引用
收藏
相关论文
共 50 条
  • [31] Modulus of Elasticity of Elastic Tubes Used in Neuromuscular Rehabilitation Programs
    Reis, Andrea Lucena
    Reis, Thais Lucena
    de Aguiar, Lucas Soares
    Soares Reis, Jose de Jesus
    Reis, Thiago Lucena
    Deus, Lysleine Alves
    Passos Neves, Rodrigo Vanerson
    Correa, Hugo de Luca
    Honorato, Fernando Sousa
    de Araujo, Thais Branquinho
    Silva, Victor Lopes
    Ide, Bernardo Neme
    Rosa, Thiago Santos
    JOURNAL OF SPORT REHABILITATION, 2022, 31 (03) : 362 - 367
  • [32] A Proposed New Measure of Corneal Sensitivity
    Efron, Nathan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (06) : 2420 - 2420
  • [33] NEW PACHYMETER TO MEASURE CORNEAL THICKNESS
    CARDONA, H
    DEVOE, AG
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1971, 72 (01) : 127 - &
  • [34] A new method to measure the contraction speed of corneal collagen under laser irradiation
    Dascalu, T
    de Leon, GC
    Saldaña, MCM
    Juarez, CJV
    ROMOPTO 2000: SIXTH CONFERENCE ON OPTICS, 2000, 4430 : 654 - 660
  • [35] A method for measuring the elastic modulus of thin films
    Shi, JD
    Wu, KH
    Larkins, G
    MATERIALS CHARACTERIZATION, 1997, 38 (4-5) : 301 - 303
  • [36] An analytical method for prediction of the elastic modulus of concrete
    Zheng, J. J.
    Li, C. Q.
    Zhou, X. Z.
    MAGAZINE OF CONCRETE RESEARCH, 2006, 58 (10) : 665 - 673
  • [37] Measurement of elastic modulus of material by the method of etalon
    Ji, Yuling
    Yingyong Jiguang/Applied Laser Technology, 1997, 17 (01): : 3 - 5
  • [38] ELASTIC SOLUTION METHOD WITH FICTITIOUS MODULUS.
    Kataev, Yu.P.
    Soviet Aeronautics (English translation of Izvestiya VUZ, Aviatsionnaya Tekhnika), 1981, 24 (02): : 27 - 29
  • [39] A numerical method for the prediction of elastic modulus of concrete
    Li, C.Q.
    Zheng, J.J.
    Zhou, X.Z.
    McCarthy, M.J.
    2003, Thomas Telford Services Ltd (55)
  • [40] A numerical method for the prediction of elastic modulus of concrete
    Li, CQ
    Zheng, JJ
    Zhou, XZ
    McCarthy, MJ
    MAGAZINE OF CONCRETE RESEARCH, 2003, 55 (06) : 497 - 505