High Repetitive Frequency Pulsed Magnetic Field Generator for Cell Activity Studies

被引:0
|
作者
Fan, Junxian [1 ,2 ]
Zhang, Shaozhe [1 ,2 ]
Li, Kexin [3 ]
Xiang, Wenpei [3 ]
Han, Xiaotao [1 ,2 ]
机构
[1] National High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan,430074, China
[2] State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan,430074, China
[3] Institute of Reproductive Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan,430074, China
关键词
Cell responses to magnetic fields obey an electromagnetic efficacy window defined by a specific combination of frequency; amplitude and time of exposure. Previous studies suggest that the specific pulsed magnetic field sequences have the potential to modulate the regulation of certain types of cells and tissues. Based on the needs of cell research; it is necessary to develop a programmable pulsed magnetic field generator with a peak magnetic field intensity up to 10 mT; a high stability; a wide range of frequency; a steep pulse edge and a configurable Inter-Stimulus Interval. However; the magnet is a large inductive load; the magnet voltage in the rising edge of the pulse needs to be tens of times higher than that in the flat top stage; which makes it challenge to adjust the magnet current with both high repetitive frequency and high precision. In this paper; a high repetitive frequency pulsed magnetic field generator to solve the above contradiction was developed. Firstly; the structure of the magnet was designed as a double-layer helical coil; and the unevenness of the cell culture area at the center was 2.4%. The ratio of magnetic field to the current in the magnet was 2 mT/A; and the requirements of the power supply were presented based on the magnet parameters. Secondly; a two-stage joint topology consisting of a synchronous Buck circuit and a bridge circuit was proposed. The working principle of the topology was explained and the calculation formulas for the parameters of the main components were derived. Lastly; in order to achieve the smooth transition of the current from the rapid rise to the stable value; the small-signal analysis of the power supply system was performed to obtain the transfer function of the duty cycle and the output current. Using the results; this paper configured a hybrid controller utilizing the time-optimal dynamic response of the hysteresis controller and the strong steady-state tracking capability of the PI controller. The feasibility of the scheme was verified by simulations. Based on these; a portable high repetitive frequency pulsed magnetic field generator with a frequency range of 1 Hz~5 kHz; pulse edge less than 50 μs; adjustable precision of 0.1 mT; and peak intensity up to 10 mT was fabricated. A user-friendly Human-Machine Interface was developed to facilitate the effortless recording of experimental data and monitoring of device status. The ratio of magnetic field to the current was measured in the experiments; and the error was less than 0.15% compared to the theoretical values. This paper tested the magnetic field waveforms for different target values; demonstrating the flexibility and the stability of the device. To mitigate the impact of parasitic capacitance on the magnet at high frequencies; the parasitic capacitance value was calculated followed by the design of a continuous current circuit to suppress the oscillation of the magnet voltage. Finally; biological experiments were carried out to observe the effect of the magnetic field on the fertilization ability and embryo development ability of oocytes from aged mice. Exposed to the 1 mT pulsed magnetic field sequence for 10 minutes; the blastocyst developmental rate increased from 15.15% to 52.94%. These results indicate that the pulsed magnetic field significantly enhances the developmental ability of oocytes in elderly mice. © 2024 China Machine Press. All rights reserved;
D O I
10.19595/j.cnki.1000-6753.tces.230649
中图分类号
学科分类号
摘要
引用
收藏
页码:3907 / 3916
相关论文
共 50 条
  • [31] ACCELERATED HIGH-FREQUENCY REPETITIVE TRANSCRANIAL MAGNETIC STIMULATION ENHANCES MOTOR ACTIVITY IN RATS
    El Arfani, Anissa
    Parthoens, Joke
    Demuyser, Thomas
    Servaes, Stijn
    De Coninck, Mattias
    De Deyn, Peter Paul
    Van Dam, Debby
    Wyckhuys, Tine
    Baeken, Chris
    Smolders, Ilse
    Staelens, Steven
    NEUROSCIENCE, 2017, 347 : 103 - 110
  • [32] Design of a 150T pulsed magnetic field generator device
    Yu, Xiao
    Xi, Weibin
    Liu, Zhimin
    Kuang, Yulong
    Li, Hang
    Fu, Xing
    Liu, Xufeng
    Xu, Weiwei
    Song, Yuntao
    Wu, Songtao
    FUSION ENGINEERING AND DESIGN, 2017, 121 : 265 - 271
  • [33] Simple economic explosive magnetic generator of high pulsed power
    Chernyshev, VK
    Vasyukov, VA
    Vakhrushev, VV
    Petrukhin, AA
    Chernyshev, VV
    PPPS-2001: PULSED POWER PLASMA SCIENCE 2001, VOLS I AND II, DIGEST OF TECHNICAL PAPERS, 2001, : 977 - 978
  • [34] The activation of cancer cells by a nanosecond-pulsed magnetic field generator
    Xu, Wenjun
    Yan, Dayun
    Sun, Jinru
    Chen, Jingliang
    Yao, Xueling
    Sherman, Jonathan H.
    Keidar, Michael
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2020, 53 (12)
  • [35] High Voltage Pulse Generator for Pulsed Electric Field Pasteurization
    Garcia Rocher, Edgar
    Alejos Palomares, Ruben
    Banuelos Sanchez, Pedro
    20TH INTERNATIONAL CONFERENCE ON ELECTRONICS COMMUNICATIONS AND COMPUTERS (CONIELECOMP 2010), 2010, : 276 - 280
  • [36] The impacts of magnetic field on repetitive nanosecond pulsed dielectric barrier discharge in air
    Liu, Yidi
    Qi, Haicheng
    Fan, Zhihui
    Yan, Huijie
    Ren, ChunSheng
    PHYSICS OF PLASMAS, 2016, 23 (11)
  • [37] A novel compact repetitive frequency voltage booster based on magnetic switches and Fitch generator
    Ren, Hang
    Ding, Weidong
    Wu, Jiawei
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (07):
  • [38] High pulsed power supply system designed for pulsed high magnetic field
    Institute of Electrical Light Sources, Fudan University, Shanghai 200433, China
    不详
    He Jishu, 2008, 11 (864-868):
  • [39] AN IRON FREE ASYNCHRONOUS PULSED GENERATOR FOR THE PRODUCTION OF PULSED HIGH MAGNETIC-FIELDS
    SULTANEM, F
    BLEIJS, CA
    POSTEL, C
    ASKENAZY, S
    MARQUEZ, J
    JOURNAL DE PHYSIQUE, 1984, 45 (NC-1): : 67 - 70
  • [40] Short-duration high-frequency quasi-sinusoidal magnetic field generator
    Robles, G
    Giannetti, R
    Frías, JDM
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (06) : 2481 - 2485