The influence of the operation parameters on SO2 removal rate with a pulsed corona discharge was studied in this paper, in order to promote the industrial applications of this technology. The flow rate of the flue gas was 1000 [similar to] 3000 m3/h. The SO2 removal rate reached 80%. The range of SO2 concentration in flue gas was 1000 [similar to] 2000 ml/m3. The flue gas temperature was 60°C [similar to] 80°C. The molecule ratio of NH3 to SO2 was 2. The energy consumption was 3 [similar to] 5W·h/Nm3. The wire-plane electrode structure and a positive high voltage pulse power supply were used in the experiment.
引用
收藏
页码:38 / 40
相关论文
共 50 条
  • [21] SO2 and NOx removal from combustion flue gas by corona discharge in laboratory-scale experiment
    Onda, K
    Kato, K
    Kasuga, Y
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1996, 39 (01) : 202 - 210
  • [22] SO2 and NOx removal from combustion flue gas by corona discharge in laboratory-scale experiment
    Onda, Kazuo
    Kato, Ken
    Kasuga, Yasuhiro
    1996, JSME, Tokyo, Japan (39)
  • [23] Effect of activated NH3 on SO2 removal by pulse corona discharge plasma in flue gas
    Li, J.
    Wu, Y.
    Wang, N.
    Yang, L.
    Journal of Environmental Sciences, 2000, 12 (04) : 448 - 451
  • [24] Modeling of corona discharge combined with Mn2+ catalysis for the removal of SO2 from simulated flue gas
    Li Jiwu
    Fan Lei
    CHEMOSPHERE, 2013, 91 (09) : 1374 - 1379
  • [25] Evaluation of Energy Utilization Efficiencies for SO2 and NO Removal by Pulsed Corona Discharge Process
    Y. S. Mok
    S. W. Ham
    I. S. Nam
    Plasma Chemistry and Plasma Processing, 1998, 18 : 535 - 550
  • [26] Evaluation of energy utilization efficiencies for SO2 and NO removal by pulsed corona discharge process
    Mok, YS
    Ham, SW
    Nam, IS
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 1998, 18 (04) : 535 - 550
  • [27] The effects of pulsed corona discharge on SO2 absorption into water
    Lee, JY
    Khang, SJ
    Tseng, CH
    Keener, TC
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2001, 40 (24) : 5822 - 5830
  • [28] Removal of SO2 from flue gas using Bayer red mud: Influence factors and mechanism
    Tao, Lei
    Wu, Heng
    Wang, Jie
    Li, Bin
    Wang, Xue-qian
    Ning, Ping
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2019, 26 (02) : 467 - 478
  • [29] Synergic effect on SO2 removal by pulsed corona with ammonia
    Zhu, Aimin
    Gong, Weimin
    Liu, Shuhai
    Zhang, Baoan
    Zhongguo Huanjing Kexue/China Environmental Science, 1997, 17 (01): : 37 - 40
  • [30] REMOVAL OF SO2 AND THE SIMULTANEOUS REMOVAL OF SO2 AND NO FROM SIMULATED FLUE-GAS STREAMS USING DIELECTRIC BARRIER DISCHARGE PLASMAS
    CHANG, MB
    KUSHNER, MJ
    ROOD, MJ
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 1992, 12 (04) : 565 - 580